Andreas Wartak

Andreas Wartak

Auto-generated profile, based on publicly available information

Andreas Wartak

Massachusetts General Hospital

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2019 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
Bernhard BaumannBernhard Baumann
Bernhard Baumann
Conrad MerkleConrad Merkle
Conrad Merkle
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb
MAMarco Augustin
Marco Augustin
AWAndreas Wartak
Andreas Wartak
CHChristoph Hitzenberger
Christoph Hitzenberger
The high acquisition speed of state-of-the-art optical coherence tomography (OCT) enables massive signal-to-noise ratio (SNR) improvements by signal averaging. Here, we investigate the performance of two commonly used approaches for OCT signal averaging. We present the theoretical SNR performance of (a) computing the average of OCT magnitude data and (b) averaging the complex phasors, and substantiate our findings with simulations and experimentally acquired OCT data. We show that the achieved SNR performance strongly depends on both the SNR of the input signals and the number of averaged signals when the signal bias caused by the noise floor is not accounted for. Therefore we also explore the SNR for the two averaging approaches after correcting for the noise bias and, provided that the phases of the phasors are accurately aligned prior to averaging, then find that complex phasor averaging always leads to higher SNR than magnitude averaging.

30 August 2018 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
Bernhard BaumannBernhard Baumann
Bernhard Baumann
MAMarco Augustin
Marco Augustin
Antonia LichteneggerAntonia Lichtenegger
Antonia Lichtenegger
DHDanielle Harper
Danielle Harper
MMMartina Muck
Martina Muck
CHChristoph Hitzenberger
Christoph Hitzenberger
Polarization-sensitive optical coherence tomography (PS-OCT) enables noninvasive, high-resolution imaging of tissue polarization properties. In the anterior segments of human eyes, PS-OCT allows the visualization of birefringent and depolarizing structures. We present the use of PS-OCT for imaging the murine anterior eye. Using a spectral domain PS-OCT setup operating in the 840-nm regime, we performed in vivo volumetric imaging in anesthetized C57BL/6 mice. The polarization properties of murine anterior eye structures largely replicated those known from human PS-OCT imagery, suggesting that the mouse eye may also serve as a model system under polarization contrast. However, dissimilarities were found in the depolarizing structure of the iris which, as we confirmed in postmortem histological sections, were caused by anatomical differences between both species. In addition to the imaging of tissues in the anterior chamber and the iridocorneal angle, we demonstrate longitudinal PS-OCT imaging of the murine anterior segment during mydriasis as well as birefringence imaging of corneal pathology in an aged mouse.

1 May 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
PEPablo Eugui
Pablo Eugui
Antonia LichteneggerAntonia Lichtenegger
Antonia Lichtenegger
MAMarco Augustin
Marco Augustin
DHDanielle Harper
Danielle Harper
MMMartina Muck
Martina Muck
Bernhard BaumannBernhard Baumann
Bernhard Baumann
Optical coherence tomography (OCT) is a powerful technology for rapid volumetric imaging in biomedicine. The bright field imaging approach of conventional OCT systems is based on the detection of directly backscattered light, thereby waiving the wealth of information contained in the angular scattering distribution. Here we demonstrate that the unique features of few-mode fibers (FMF) enable simultaneous bright and dark field (BRAD) imaging for OCT. As backscattered light is picked up by the different modes of a FMF depending upon the angular scattering pattern, we obtain access to the directional scattering signatures of different tissues by decoupling illumination and detection paths. We exploit the distinct modal propagation properties of the FMF in concert with the long coherence lengths provided by modern wavelength-swept lasers to achieve multiplexing of the different modal responses into a combined OCT tomogram. We demonstrate BRAD sensing for distinguishing differently sized microparticles and showcase the performance of BRAD-OCT imaging with enhanced contrast for ex vivo tumorous tissue in glioblastoma and neuritic plaques in Alzheimer’s disease.

13 November 2017 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
AWAndreas Wartak
Andreas Wartak
MAMarco Augustin
Marco Augustin
Richard HaindlRichard Haindl
Richard Haindl
FBFlorian Beer
Florian Beer
MSMatthias Salas
Matthias Salas
CHChristoph K. Hitzenberger
Christoph K. Hitzenberger
We introduce multi-directional optical coherence tomography (OCT), a technique for investigation of the scattering properties of directionally reflective tissue samples. By combining the concepts of multi-channel and directional OCT, this approach enables simultaneous acquisition of multiple reflectivity depth-scans probing a mutual sample location from differing angular orientations. The application of multi-directional OCT in retinal imaging allows for in-depth investigations on the directional reflectivity of the retinal nerve fiber layer, Henle’s fiber layer and the photoreceptor layer. Major ophthalmic diseases (such as glaucoma or age-related macular degeneration) have been reported to alter the directional reflectivity properties of these retinal layers. Hence, the concept of multi-directional OCT might help to gain improved understanding of pathology development and progression. As a first step, we demonstrate the capabilities of multi-directional OCT in the eyes of healthy human volunteers.

13 June 2018 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
LWLara Wurster
Lara Wurster
LGLaurin Ginner
Laurin Ginner
AKAbhishek Kumar
Abhishek Kumar
MSMatthias Salas
Matthias Salas
AWAndreas Wartak
Andreas Wartak
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb
Optical coherence tomography (OCT) is a noninvasive imaging technique that performs cross-sectional imaging of transparent, translucent, or turbid media at a micrometer scale resolution.1 Being already well established in ophthalmology,2 OCT also holds the potential to become an important tool for in vivo imaging of internal organs by combination with endoscopy. To investigate less accessible tissues in the human body and tissues shielded by opaque media, an integration of the coherent imaging technique into endoscopic instruments proved successful.3,4 Cancer lesions and other types of pathologic tissue changes typically arise from close underneath the tissue surface, which is well accessible for OCT. Therefore, endoscopic OCT enables disease diagnosis in internal organs at an early stage and complements the information obtained by white-light endoscopy.5 In a best-case scenario, thus, endoscopic OCT avoids the need to remove tissue samples by providing morphological tissue information at up to 2 mm in depth and, therefore, also being considered as “optical biopsy.”5 Furthermore, endoscopic OCT shows a tremendous impact in imaging of regions where common biopsy cannot be performed without introducing major risks, e.g., in the vascular system or in the brain.6

26 March 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
MSMatthias Salas
Matthias Salas
MAMarco Augustin
Marco Augustin
FFFranz Felberer
Franz Felberer
AWAndreas Wartak
Andreas Wartak
MLMarie Laslandes
Marie Laslandes
Michael PircherMichael Pircher
Michael Pircher
Imaging of the human retina with high resolution is an essential step towards improved diagnosis and treatment control. In this paper, we introduce a compact, clinically user-friendly instrument based on swept source optical coherence tomography (SS-OCT). A key feature of the system is the realization of two different operation modes. The first operation mode is similar to conventional OCT imaging and provides large field of view (FoV) images (up to 45° × 30°) of the human retina and choroid with standard resolution. The second operation mode enables it to optically zoom into regions of interest with high transverse resolution using adaptive optics (AO). The FoV of this second operation mode (AO-OCT mode) is 3.0° × 2.8° and enables the visualization of individual retinal cells such as cone photoreceptors or choriocapillaris. The OCT engine is based on an akinetic swept source at 1060 nm and provides an A-scan rate of 200 kHz. Structural as well as angiographic information can be retrieved from the retina and choroid in both operational modes. The capabilities of the prototype are demonstrated in healthy and diseased eyes.