As a high-quality building material exhibiting excellent toughness and durability, ultrahigh-performance concrete (UHPC) is increasingly being used in the construction industry and as building reinforcement. During the reinforcement of existing concrete structures with UHPC, their interface is the weakest part of a structure. Interface bonding ensures the operation of two types of materials together. However, existing studies rarely report the bonding of the UHPC–normal concrete (NC) interface. Herein, the existing test methods and interface bonding mechanisms are summarized. Subsequently, the differences among relevant design codes are investigated by comparing different theoretical formulas. Important influencing factors of the reinforcement method, namely, interface roughness, fiber type and content, interface agent type and content, moisture content, existing concrete strength, cementitious material content, curing conditions, freeze–thaw cycles, and chloride ions, are also considered. Further, the enhancement mechanism of the characteristics of the UHPC–NC interface is clearly described. Finally, the shortcomings and application prospects of the interfacial bonding properties are highlighted.
Different from previous researches which mostly focused on linear response control of seismically excited high-rise buildings, this study aims to control nonlinear seismic response of high-rise buildings. To this end, a semi-active control strategy, in which H∞ control algorithm is used and magneto-rheological dampers are employed for an actuator, is presented to suppress the nonlinear vibration. In this strategy, a modified Kalman–Bucy observer which is suitable for the proposed semi-active strategy is developed to obtain the state vector from the measured semi-active control force and acceleration feedback, taking into account of the effects of nonlinearity, disturbance and uncertainty of controlled system parameters by the observed nonlinear accelerations. Then, the proposed semi-active H∞ control strategy is applied to the ASCE 20-story benchmark building when subjected to earthquake excitation and compared with the other control approaches by some control criteria. It is indicated that the proposed semi-active H∞ control strategy provides much better control performances by comparison with the semi-active MPC and Clipped-LQG control approaches, and can reduce nonlinear seismic response and minimize the damage in the buildings. Besides, it enhances the reliability of the control performance when compared with the active control strategy. Thus, the proposed semi-active H∞ control strategy is suitable for suppressing the nonlinear vibration of high-rise buildings.
Mid-story isolation eccentric structures with tower–podium are examples of vertically irregular structures. Its seismic performance and the related mechanisms, however, have not been experimentally examined. In this study, a representative model of a practical mid-story isolation eccentric structure with a large podium was fabricated, tested, and simulated to investigate its seismic response under different earthquakes. The results were then compared to those of an anti-seismic model without the isolation layer. The results show that (a) the mid-story isolation eccentric structure with tower–podium has the similar characteristics of seismic performance with the regular story isolation structure; (b) as the peak acceleration value increases, the podium could quickly enter the elastoplastic state and reach the medium damage level. The damage extent in the second layer of the podium is larger than that in its first layer. It is thus recommended that the structural components of the podium be strengthened, and the elastoplastic displacement angle limit of the podium be increased. The modeling results also indicate the torsional effects of such eccentric structure are effectively inhibited. Our study enhances the understanding of the mid-story isolation eccentric structure with tower–podium and pioneers a guide to the seismic design of such a structure.
There are a few isolated structures that have been subjected to seismic testing. An isolated structure is incapable of tracking, adjusting, and controlling its dynamic characteristics. As a result, field evaluations of solitary structures’ dynamic characteristics are important. The horizontal initial displacement of a base isolation kindergarten made of 46 isolation bearings is 75 mm. The method for creating the horizontal initial displacement condition is illustrated, as are the primary test findings. Horizontal initial displacement is accomplished with the assistance of a reaction wall, rods, and hydraulic pump system. To begin, we removed the building using hydraulic jacks to produce horizontal displacement of the isolation layer and then attached rods to support the building. The rods were then shot and unloaded, causing the building to shake freely, and its dynamic response and other parameters were tested. The results indicate that the natural vibration period of an isolated structure is much greater than the natural vibration period of a seismic structure. The isolation layer’s hysteretic curve as completely filled; upon unloading, the isolation layer as promptly reset; the dynamic response control effect of each was visible, but the top floor’s acceleration was magnified by approximately 1.27 times.
This study proposes a new structural design of the first-story isolation system in reinforced concrete (RC) structures. Compared to the conditional buildings with independent columns, this new design integrates the independent columns with beams to increase the seismic capacity of the building by increasing the integrated stiffness of the coupled columns and the stability of the isolation system. The seismic responses of the proposed structure and the corresponding isolation effect were investigated by performing a series of numerical simulation and shaking table tests on a typical 7-story RC frame structure. The structure models were subjected to four earthquake waves with two PGAs (peak ground acceleration) of 0.30 g and 0.40 g for seismic analysis regarding the peak acceleration and inter-story displacement. Both simulation and testing results showed that the story acceleration and inter-story displacement of the superstructure in the isolated model decreased significantly. While the substructure below the isolation layer had a negligible decrease of acceleration. The connection of beams with concrete columns significantly increases the seismic capacity of the RC frame buildings compared to non-isolated frame buildings. The coupled beam-column connections could thus be potentially adopted in the practical first-story isolation system to avoid the requirements of large column stiffness and large column size.