Dong-Weon Lee

Dr. Dong-Weon Lee

MEMS and Nanotechnology Laboratory, School of Mechanical Engineering, Chonnam National University, Gwangju 61186, Korea

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2016 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
GLGuangyong Li
Guangyong Li
XWXuan Wu
Xuan Wu
Dong-Weon LeeDong-Weon Lee
Dong-Weon Lee
We present a novel approach to realize highly stretchable electronics with self-healing capability by using a galinstan-based inkjet nozzle, which consists of a main microfluidic channel and a coplanar channel.

27 January 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
DKDong-Su Kim
Dong-Su Kim
YCYong Whan Choi
Yong Whan Choi
ASArunkumar Shanmugasundaram
Arunkumar Shanmugasundaram
YJYun-Jin Jeong
Yun-Jin Jeong
JPJongsung Park
Jongsung Park
Dong-Weon LeeDong-Weon Lee
Dong-Weon Lee
To date, numerous biosensing platforms have been developed for assessing drug-induced cardiac toxicity by measuring the change in contractile force of cardiomyocytes. However, these low sensitivity, low-throughput, and time-consuming processes are severely limited in their real-time applications. Here, we propose a cantilever device integrated with a polydimethylsiloxane (PDMS)-encapsulated crack sensor to measure cardiac contractility. The crack sensor is chemically bonded to a PDMS thin layer that allows it to be operated very stably in culture media. The reliability of the proposed crack sensor has been improved dramatically compared to no encapsulation layer. The highly sensitive crack sensor continuously measures the cardiac contractility without changing its gauge factor for up to 26 days (>5 million heartbeats), while changes in contractile force induced by drugs are monitored using the crack sensor-integrated cantilever. Finally, experimental results are compared with those obtained via conventional optical methods to verify the feasibility of building a contraction-based drug-toxicity testing system.

9 January 2023 in Nano Energy
Verified
Journal Article
Closed access
Prasad GajulaPrasad Gajula
Prasad Gajula
SGSontyana Adonijah Graham
Sontyana Adonijah Graham
JYJae Su Yu
Jae Su Yu
HKHongdoo Kim
Hongdoo Kim
Dong-Weon LeeDong-Weon Lee
Dong-Weon Lee

22 August 2017 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
GLGuangyong Li
Guangyong Li
Dong-Weon LeeDong-Weon Lee
Dong-Weon Lee
This paper presents a novel stretchable pulse sensor fabricated by a selective liquid-metal plating process (SLMP), which can conveniently attach to the human skin and monitor the patient's heartbeat.

2 June 2016 in Sensors
Verified
Journal Article
Open access
PDF file
JPJongsung Park
Jongsung Park
JKJi Kwan Kim
Ji Kwan Kim
SPSwati J. Patil
Swati J. Patil
JPJun-Kyu Park
Jun-Kyu Park
SPSu A. Park
Su A. Park
Dong-Weon LeeDong-Weon Lee
Dong-Weon Lee
This paper describes the fabrication and characterization of a wireless pressure sensor for smart stent applications. The micromachined pressure sensor has an area of 3.13 × 3.16 mm2 and is fabricated with a photosensitive SU-8 polymer. The wireless pressure sensor comprises a resonant circuit and can be used without the use of an internal power source. The capacitance variations caused by changes in the intravascular pressure shift the resonance frequency of the sensor. This change can be detected using an external antenna, thus enabling the measurement of the pressure changes inside a tube with a simple external circuit. The wireless pressure sensor is capable of measuring pressure from 0 mmHg to 230 mmHg, with a sensitivity of 0.043 MHz/mmHg. The biocompatibility of the pressure sensor was evaluated using cardiac cells isolated from neonatal rat ventricular myocytes. After inserting a metal stent integrated with the pressure sensor into a cardiovascular vessel of an animal, medical systems such as X-ray were employed to consistently monitor the condition of the blood vessel. No abnormality was found in the animal blood vessel for approximately one month. Furthermore, a biodegradable polymer (polycaprolactone) stent was fabricated with a 3D printer. The polymer stent exhibits better sensitivity degradation of the pressure sensor compared to the metal stent.

1 November 2021 in Biomaterials
Verified
Journal Article
Closed access
ARAmir Roshanzadeh
Amir Roshanzadeh
NONomin-Erdene Oyunbaatar
Nomin-Erdene Oyunbaatar
SGSarina Ehteshamzadeh Ganjbakhsh
Sarina Ehteshamzadeh Ganjbakhsh
SPSangwoo Park
Sangwoo Park
DKDong-Su Kim
Dong-Su Kim
EKEung-Sam Kim
Eung-Sam Kim