Feng CHAI

Dr. Feng CHAI

Université Lille, Inserm, CHU Lille, U1008—Controlled Drug Delivery Systems and Biomaterials, Lille, France

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2022 in Materials Today Bio
Verified
Journal Article
Open access
SRS. Kotagudda Ranganath
S. Kotagudda Ranganath
MSM. Schlund
M. Schlund
JDJérôme Delattre
Jérôme Delattre
JFJ. Ferri
J. Ferri
FCFeng CHAI
Feng CHAI
Most existing preclinical models for evaluating the biosafety and bone-regeneration efficacy of innovative bone substitute materials (BSMs) or tissue engineering (TE) constructs only consisted of a single-site defect and the anatomical locations of defect varied drastically. While the compelling evidence showed that the bone healing pattern is location-dependent, owing to developmental, structural, and functional differences of anatomical locations, this is particularly true for the craniofacial region. Taking this into account, the bone healing efficiency of a BSM shown at one anatomical defect location cannot ensure the same impact at another. This prompted us to develop, for the first time, a model of bilateral critical-sized defect (CSD) at two distinctly different locations (non-load-bearing parietal calvaria and load-bearing mandibular body) co-existing in one rabbit to reduce the number of animals needed and avoid the influence of interindividual variability and evaluation bias on comparisons.

30 January 2023 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
MMMarie-Stella M’bengue
Marie-Stella M’bengue
TMThomas Mesnard
Thomas Mesnard
FCFeng CHAI
Feng CHAI
MMMickaël Maton
Mickaël Maton
VGValerie Gaucher
Valerie Gaucher
NBNicolas Blanchemain
Nicolas Blanchemain
Three-dimensional printing (3DP) of thermoplastic polyurethane (TPU) is gaining interest in the medical industry thanks to the combination of tunable properties that TPU exhibits and the possibilities that 3DP processes offer concerning precision, time, and cost of fabrication. We investigated the implementation of a medical grade TPU by fused deposition modelling (FDM) for the manufacturing of an implantable medical device from the raw pellets to the gamma (γ) sterilized 3DP constructs. To the authors’ knowledge, there is no such guide/study implicating TPU, FDM 3D-printing and gamma sterilization. Thermal properties analyzed by differential scanning calorimetry (DSC) and molecular weights measured by size exclusion chromatography (SEC) were used as monitoring indicators through the fabrication process. After gamma sterilization, surface chemistry was assessed by water contact angle (WCA) measurement and infrared spectroscopy (ATR-FTIR). Mechanical properties were investigated by tensile testing. Biocompatibility was assessed by means of cytotoxicity (ISO 10993-5) and hemocompatibility assays (ISO 10993-4). Results showed that TPU underwent degradation through the fabrication process as both the number-averaged (Mn) and weight-averaged (Mw) molecular weights decreased (7% Mn loss, 30% Mw loss, p < 0.05). After gamma sterilization, Mw increased by 8% (p < 0.05) indicating that crosslinking may have occurred. However, tensile properties were not impacted by irradiation. Cytotoxicity (ISO 10993-5) and hemocompatibility (ISO 10993-4) assessments after sterilization showed vitality of cells (132% ± 3%, p < 0.05) and no red blood cell lysis. We concluded that gamma sterilization does not highly impact TPU regarding our application. Our study demonstrates the processability of TPU by FDM followed by gamma sterilization and can be used as a guide for the preliminary evaluation of a polymeric raw material in the manufacturing of a blood contacting implantable medical device.

14 February 2021 in Polymers
Verified
Journal Article
Open access
PDF file
MGMarion GRADWOHL
Marion GRADWOHL
FCFeng CHAI
Feng CHAI
JPJulien Payen
Julien Payen
PGPierre Guerreschi
Pierre Guerreschi
PMPhilippe Marchetti
Philippe Marchetti
NBNicolas Blanchemain
Nicolas Blanchemain
Although bioabsorbable polymers have garnered increasing attention because of their potential in tissue engineering applications, to our knowledge there are only a few bioabsorbable 3D printed medical devices on the market thus far. In this study, we assessed the processability of medical grade Poly(lactic-co-glycolic) Acid (PLGA)85:15 via two additive manufacturing technologies: Fused Filament Fabrication (FFF) and Direct Pellet Printing (DPP) to highlight the least destructive technology towards PLGA. To quantify PLGA degradation, its molecular weight (gel permeation chromatography (GPC)) as well as its thermal properties (differential scanning calorimetry (DSC)) were evaluated at each processing step, including sterilization with conventional methods (ethylene oxide, gamma, and beta irradiation). Results show that 3D printing of PLGA on a DPP printer significantly decreased the number-average molecular weight (Mn) to the greatest extent (26% Mn loss, p < 0.0001) as it applies a longer residence time and higher shear stress compared to classic FFF (19% Mn loss, p < 0.0001). Among all sterilization methods tested, ethylene oxide seems to be the most appropriate, as it leads to no significant changes in PLGA properties. After sterilization, all samples were considered to be non-toxic, as cell viability was above 70% compared to the control, indicating that this manufacturing route could be used for the development of bioabsorbable medical devices. Based on our observations, we recommend using FFF printing and ethylene oxide sterilization to produce PLGA medical devices.

26 January 2019 in Polymers
Verified
Journal Article
Open access
PDF file
CPCarla Palomino-Durand
Carla Palomino-Durand
MLMarco Lopez
Marco Lopez
FCFrédéric Cazaux
Frédéric Cazaux
BMBernard Martel
Bernard Martel
NBNicolas Blanchemain
Nicolas Blanchemain
FCFeng CHAI
Feng CHAI
Injectable pre-formed physical hydrogels provide many advantages for biomedical applications. Polyelectrolyte complexes (PEC) formed between cationic chitosan (CHT) and anionic polymers of cyclodextrin (PCD) render a hydrogel of great interest. Given the difference between water-soluble (PCDs) and water-insoluble PCD (PCDi) in the extension of polymerization, the present study aims to explore their impact on the formation and properties of CHT/PCD hydrogel obtained from the variable ratios of PCDi and PCDs in the formulation. Hydrogels CHT/PCDi/PCDs at weight ratios of 3:0:3, 3:1.5:1.5, and 3:3:0 were elaborated in a double–syringe system. The chemical composition, microstructure, viscoelastic properties, injectability, and structural integrity of the hydrogels were investigated. The cytotoxicity of the hydrogel was also evaluated by indirect contact with pre-osteoblast cells. Despite having similar shear–thinning and self-healing behaviors, the three hydrogels showed a marked difference in their rheological characteristics, injectability, structural stability, etc., depending on their PCDi and PCDs contents. Among the three, all the best above-mentioned properties, in addition to a high cytocompatibility, were found in the hydrogel 3:1.5:1.5. For the first time, we gained a deeper understanding of the role of the PCDi/PCDs in the injectable pre-formed hydrogels (CHT/PCDi/PCDs), which could be further fine-tuned to enhance their performance in biomedical applications.

1 November 2022 in Journal of Stomatology Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
MSMatthias Schlund
Matthias Schlund
ADArnaud Depeyre
Arnaud Depeyre
SRSindhu Kotagudda Ranganath
Sindhu Kotagudda Ranganath
PMPierre Marchandise
Pierre Marchandise
JFJoël Ferri
Joël Ferri
FCFeng CHAI
Feng CHAI

22 March 2023 in Gels
Verified
Journal Article
Open access
PDF file
HCHenry Richard CHIJCHEAPAZA-FLORES
Henry Richard CHIJCHEAPAZA-FLORES
NTNicolas Tabary
Nicolas Tabary
FCFeng CHAI
Feng CHAI
MMMickaël Maton
Mickaël Maton
Jean-Noël STAELENSJean-Noël STAELENS
Jean-Noël STAELENS
MFMaria-Jose Garcia Fernandez
Maria-Jose Garcia Fernandez
Diabetic foot ulcers (DFU) are among the most common complications in diabetic patients and affect 6.8% of people worldwide. Challenges in the management of this disease are decreased blood diffusion, sclerotic tissues, infection, and antibiotic resistance. Hydrogels are now being used as a new treatment option since they can be used for drug delivery and to improve wound healing. This project aims to combine the properties of hydrogels based on chitosan (CHT) and the polymer of β cyclodextrin (PCD) for local delivery of cinnamaldehyde (CN) in diabetic foot ulcers. This work consisted of the development and characterisation of the hydrogel, the evaluation of the CN release kinetics and cell viability (on a MC3T3 pre-osteoblast cell line), and the evaluation of the antimicrobial and antibiofilm activity (S. aureus and P. aeruginosa). The results demonstrated the successful development of a cytocompatible (ISO 10993-5) injectable hydrogel with antibacterial (99.99% bacterial reduction) and antibiofilm activity. Furthermore, a partial active molecule release and an increase in hydrogel elasticity were observed in the presence of CN. This leads us to hypothesise that a reaction between CHT and CN (a Schiff base) can occur and that CN could act as a physical crosslinker, thus improving the viscoelastic properties of the hydrogel and limiting CN release.