Colin Dalton

Prof. Colin Dalton

University of Calgary
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2006 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
YLYoulan Li
Youlan Li
Colin DaltonColin Dalton
Colin Dalton
HCH. John Crabtree
H. John Crabtree
GNGregory Nilsson
Gregory Nilsson
KKKaran V. I. S. Kaler
Karan V. I. S. Kaler
We present a prototype microfluidic device developed for the continuous dielectrophoretic (DEP) fractionation and purification of sample suspensions of biological cells. The device integrates three fully functional and distinct units consisting of an injector, a fractionation region, and two outlets. In the sheath and sample injection ports, the cell sample are hydrodynamically focused into a stream of controlled width; in the DEP fractionation region, a specially shaped nonuniform (isomotive) electric field is synthesized and employed to facilitate the separation, and the sorted cells are then delivered to two sample collection ports. The microfluidic behavior of the injector region was simulated and then experimentally verified. The operation and performance of the device was evaluated using yeast cells as model biological particles. Issues relating to the fabrication and operation of the device are discussed in detail. Such a device takes a significant step towards an integrated lab-on-a-chip device, which could interface/integrate to a number of other on-chip components for the device to undertake the whole laboratory procedure.

1 March 2012 in Journal of Neurosurgery
Verified
Journal Article
Closed access
BSBhagat Singh
Bhagat Singh
QXQing-Gui Xu
Qing-Gui Xu
CFColin Franz
Colin Franz
RZRumi Zhang
Rumi Zhang
Colin DaltonColin Dalton
Colin Dalton
DZDouglas W. Zochodne
Douglas W. Zochodne
Object: Regeneration of peripheral nerves is remarkably restrained across transection injuries, limiting recovery of function. Strategies to reverse this common and unfortunate outcome are limited. Remarkably, however, new evidence suggests that a brief extracellular electrical stimulation (ES), delivered at the time of injury, improves the regrowth of motor and sensory axons. Methods: In this work, the authors explored and tested this ES paradigm, which was applied proximal to transected sciatic nerves in mice, and identified several novel and compelling impacts of the approach. Using thy-1 yellow fluorescent protein mice with fluorescent axons that allow serial in vivo tracking of regeneration, the morphological, electrophysiological, and behavioral indices of nerve regrowth were measured. Results: The authors show that ES is associated with a 30%–50% improvement in several indices of regeneration: regrowth of axons and their partnered Schwann cells across transection sites, maturation of regenerated fibers in gaps spanning transection zones, and entry of axons into their muscle and cutaneous target zones. In parallel studies, the authors analyzed adult sensory neurons and their response to extracellular ES while plated on a novel microelectrode array construct designed to deliver the identical ES paradigm used in vivo. The ES accelerated neurite outgrowth, supporting the concept of a neuron-autonomous mechanism of action. Conclusions: Taken together, these results support a robust role for brief ES following peripheral nerve injuries in promoting regeneration. Electrical stimulation has a wider repertoire of impact than previously recognized, and its impact in vitro supports the hypothesis that a neuron-specific reprogrammed injury response is recruited by the ES protocol.

1 September 2004 in Journal of Microbiological Methods
Verified
Journal Article
Closed access
ECEsther G. Cen
Esther G. Cen
Colin DaltonColin Dalton
Colin Dalton
YLYoulan Li
Youlan Li
SASophia Adamia
Sophia Adamia
LPLinda M. Pilarski
Linda M. Pilarski
KKKaran V.I.S. Kaler
Karan V.I.S. Kaler

1 July 2003 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JEJ.C.T Eijkel
J.C.T Eijkel
Colin DaltonColin Dalton
Colin Dalton
CHC.J Hayden
C.J Hayden
JBJ.P.H Burt
J.P.H Burt
AMAndreas Manz
Andreas Manz

11 November 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
ASAli Salari
Ali Salari
MNMaryam Navi
Maryam Navi
Thomas LijnseThomas Lijnse
Thomas Lijnse
Colin DaltonColin Dalton
Colin Dalton
The electrothermal effect has been investigated extensively in microfluidics since the 1990s and has been suggested as a promising technique for fluid manipulations in lab-on-a-chip devices. The purpose of this article is to provide a timely overview of the previous works conducted in the AC electrothermal field to provide a comprehensive reference for researchers new to this field. First, electrokinetic phenomena are briefly introduced to show where the electrothermal effect stands, comparatively, versus other mechanisms. Then, recent advances in the electrothermal field are reviewed from different aspects and categorized to provide a better insight into the current state of the literature. Results and achievements of different studies are compared, and recommendations are made to help researchers weigh their options and decide on proper configuration and parameters.

25 March 2004 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SDS. Debesset
S. Debesset
CHC. J. Hayden
C. J. Hayden
Colin DaltonColin Dalton
Colin Dalton
JEJ. C. T. Eijkel
J. C. T. Eijkel
AMAndreas Manz
Andreas Manz
Flow rates of up to 50 µm s−1 have been successfully achieved in a closed-loop channel using an AC electroosmotic pump. The AC electroosmotic pump is made of an interdigitated array of unequal width electrodes located at the bottom of a channel, with an AC voltage applied between the small and the large electrodes. The flow rate was found to increase linearly with the applied voltage and to decrease linearly with the applied frequency. The pump is expected to be suitable for circular chromatography for the following reasons: the driving forces are distributed over the channel length and the pumping direction is set by the direction of the interdigitated electrodes. Pumping in a closed-loop channel can be achieved by arranging the electrode pattern in a circle. In addition the inherent working principle of AC electroosmotic pumping enables the independent optimisation of the channel height or the flow velocity.