Justin Williams

Dr. Justin Williams


Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2014 in Nature Communications
Verified
Journal Article
Open access
DPDong-Wook Park
Dong-Wook Park
ASAmelia A. Schendel
Amelia A. Schendel
SMSolomon Mikael
Solomon Mikael
SBSarah K. Brodnick
Sarah K. Brodnick
TRThomas J. Richner
Thomas J. Richner
JWJustin Williams
Justin Williams
Neural micro-electrode arrays that are transparent over a broad wavelength spectrum from ultraviolet to infrared could allow for simultaneous electrophysiology and optical imaging, as well as optogenetic modulation of the underlying brain tissue. The long-term biocompatibility and reliability of neural micro-electrodes also require their mechanical flexibility and compliance with soft tissues. Here we present a graphene-based, carbon-layered electrode array (CLEAR) device, which can be implanted on the brain surface in rodents for high-resolution neurophysiological recording. We characterize optical transparency of the device at >90% transmission over the ultraviolet to infrared spectrum and demonstrate its utility through optical interface experiments that use this broad spectrum transparency. These include optogenetic activation of focal cortical areas directly beneath electrodes, in vivo imaging of the cortical vasculature via fluorescence microscopy and 3D optical coherence tomography. This study demonstrates an array of interfacing abilities of the CLEAR device and its utility for neural applications.

27 November 2007 in Journal of Neural Engineering
Verified
Journal Article
Closed access
JWJustin Williams
Justin Williams
JHJoseph A Hippensteel
Joseph A Hippensteel
JDJohn Dilgen
John Dilgen
WSWilliam Shain
William Shain
DKDaryl R Kipke
Daryl R Kipke
A series of animal experiments was conducted to characterize changes in the complex impedance of chronically implanted electrodes in neural tissue. Consistent trends in impedance changes were observed across all animals, characterized as a general increase in the measured impedance magnitude at 1 kHz. Impedance changes reach a peak approximately 7 days post-implant. Reactive responses around individual electrodes were described using immuno- and histo-chemistry and confocal microscopy. These observations were compared to measured impedance changes. Several features of impedance changes were able to differentiate between confined and extensive histological reactions. In general, impedance magnitude at 1 kHz was significantly increased in extensive reactions, starting about 4 days post-implant. Electrodes with extensive reactions also displayed impedance spectra with a characteristic change at high frequencies. This change was manifested in the formation of a semi-circular arc in the Nyquist space, suggestive of increased cellular density in close proximity to the electrode site. These results suggest that changes in impedance spectra are directly influenced by cellular distributions around implanted electrodes over time and that impedance measurements may provide an online assessment of cellular reactions to implanted devices.

9 March 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
ZMZakir Mridha
Zakir Mridha
JGJan Willem de Gee
Jan Willem de Gee
YSYanchen Shi
Yanchen Shi
RARayan Alkashgari
Rayan Alkashgari
JWJustin Williams
Justin Williams
MMMatthew James McGinley
Matthew James McGinley
Vagus nerve stimulation (VNS) is thought to affect neural activity by recruiting brain-wide release of neuromodulators. VNS is used in treatment-resistant epilepsy, and is increasingly being explored for other disorders, such as depression, and as a cognitive enhancer. However, the promise of VNS is only partially fulfilled due to a lack of mechanistic understanding of the transfer function between stimulation parameters and neuromodulatory response, together with a lack of biosensors for assaying stimulation efficacy in real time. We here develop an approach to VNS in head-fixed mice on a treadmill and show that pupil dilation is a reliable and convenient biosensor for VNS-evoked cortical neuromodulation. In an ‘optimal’ zone of stimulation parameters, current leakage and off-target effects are minimized and the extent of pupil dilation tracks VNS-evoked basal-forebrain cholinergic axon activity in neocortex. Thus, pupil dilation is a sensitive readout of the moment-by-moment, titratable effects of VNS on brain state.

30 March 2012 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
YHYu Huang
Yu Huang
JWJustin Williams
Justin Williams
SJStephen M. Johnson
Stephen M. Johnson
Isolated brain tissue, especially brain slices, are valuable experimental tools for studying neuronal function at the network, cellular, synaptic, and single channel levels. Neuroscientists have refined the methods for preserving brain slice viability and function and converged on principles that strongly resemble the approach taken by engineers in developing microfluidic devices. With respect to brain slices, microfluidic technology may 1) overcome the traditional limitations of conventional interface and submerged slice chambers and improve oxygen/nutrient penetration into slices, 2) provide better spatiotemporal control over solution flow/drug delivery to specific slice regions, and 3) permit successful integration with modern optical and electrophysiological techniques. In this review, we highlight the unique advantages of microfluidic devices for in vitro brain slice research, describe recent advances in the integration of microfluidic devices with optical and electrophysiological instrumentation, and discuss clinical applications of microfluidic technology as applied to brain slices and other non-neuronal tissues. We hope that this review will serve as an interdisciplinary guide for both neuroscientists studying brain tissue in vitro and engineers as they further develop microfluidic chamber technology for neuroscience research.

20 March 2013 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
JWJustin Williams
Justin Williams
TDTimothy Denison
Timothy Denison
Translating optogenetic technologies into the clinic will encounter a number of technical, practical, and regulatory hurdles.

20 October 2014 in ACS Nano
Verified
Journal Article
Open access
PFPaul Froeter
Paul Froeter
YHYu Huang
Yu Huang
OCOlivia V. Cangellaris
Olivia V. Cangellaris
WHWen Huang
Wen Huang
EDErik W. Dent
Erik W. Dent
XLXiuling Li
Xiuling Li
In neural interface platforms, cultures are often carried out on a flat, open, rigid, and opaque substrate, posing challenges to reflecting the native microenvironment of the brain and precise engagement with neurons. Here we present a neuron cell culturing platform that consists of arrays of ordered microtubes (2.7–4.4 μm in diameter), formed by strain-induced self-rolled-up nanomembrane (s-RUM) technology using ultrathin (<40 nm) silicon nitride (SiNx) film on transparent substrates. These microtubes demonstrated robust physical confinement and unprecedented guidance effect toward outgrowth of primary cortical neurons, with a coaxially confined configuration resembling that of myelin sheaths. The dynamic neural growth inside the microtube, evaluated with continuous live-cell imaging, showed a marked increase (20×) of the growth rate inside the microtube compared to regions outside the microtubes. We attribute the dramatic accelerating effect and precise guiding of the microtube array to three-dimensional (3D) adhesion and electrostatic interaction with the SiNx microtubes, respectively. This work has clear implications toward building intelligent synthetic neural circuits by arranging the size, site, and patterns of the microtube array, for potential treatment of neurological disorders.