Chin-Yu Lin

Dr. Chin-Yu Lin

Institute of New Drug Development, College of Medicine, China Medical University, Taichung, 40402, Taiwan.
+2
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2022 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
Chin-Yu LinChin-Yu Lin
Chin-Yu Lin
YWYung-Li Wang
Yung-Li Wang
YCYu-Jen Chen
Yu-Jen Chen
CHChun-Te Ho
Chun-Te Ho
YCYi-Hsuan Chi
Yi-Hsuan Chi
Shih-Chieh HungShih-Chieh Hung
Shih-Chieh Hung

1 January 2021 in Journal of Controlled Release
Verified
Journal Article
Closed access
Chin-Yu LinChin-Yu Lin
Chin-Yu Lin
YHYun-Ting Hsieh
Yun-Ting Hsieh
LCLong Yi Chan
Long Yi Chan
TYTing-Ya Yang
Ting-Ya Yang
TMTomoji Maeda
Tomoji Maeda
HHHuey-Chun Huang
Huey-Chun Huang

5 January 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
LCLong Yi Chan
Long Yi Chan
Yit Lung KhungYit Lung Khung
Yit Lung Khung
Chin-Yu LinChin-Yu Lin
Chin-Yu Lin
The specific delivery of messenger RNA (mRNA) is an excellent alternative to plasmid DNA, due to the latter’s potential risk for random integration into the host genome. In this study, we propose the use of specially tailored polyplex nanomicelles for the intravenous delivery of mRNA into the brain of mice. In brief, along the backbone of a polyaspartamide polymer that is terminated with a 42k Polyethylene glycol chain (PEG), aminoethylene-repeating groups (two, three, and four units, respectively) were conjugated to side-chains to promote electrostatic interactions with mRNA. This structural configuration would ultimately condense into a polyplex nanomicelle ranging between 24 and 34 nm, as was confirmed by transmission electron microscopy (TEM) and dynamic light scattering (DLS) while the chemistry of the synthesis was validated through NMR analysis. Subsequently, we hypothesized an important correlation pertaining to the role of hydrogen bonding between the interaction of polyamine and mRNA in due course. As a proof of concept, we encapsulated the luciferase (Luc2) mRNA as a reporter gene through in vitro transcription (IVT) and subsequently infused the polyplex nanomicelles into mouse brains via an intracerebroventricular (ICV) injection to bypass the blood–brain barriers (BBB). Data revealed that PEGylated polyplex nanomicelles possessing four repeating units of aminoethylene groups had exhibited the best Luc2 mRNA delivery efficiency with no significant immune response registered.

Verified
Journal Article
Open access
PDF file
CCCheng-Chung Chang
Cheng-Chung Chang
HTHsi-Kai Tsou
Hsi-Kai Tsou
HCHsu-Hsin Chang
Hsu-Hsin Chang
LCLong Yi Chan
Long Yi Chan
GZGuan-Yu Zhuo
Guan-Yu Zhuo
Chin-Yu LinChin-Yu Lin
Chin-Yu Lin
Vertebral disc degenerative disease (DDD) affects millions of people worldwide and is a critical factor leading to low back and neck pain and consequent disability. Currently, no strategy has addressed curing DDD from fundamental aspects, because the pathological mechanism leading to DDD is still controversial. One possible mechanism points to the homeostatic status of extracellular matrix (ECM) anabolism, and catabolism in the disc may play a vital role in the disease’s progression. If the damaged disc receives an abundant amount of cartilage, anabolic factors may stimulate the residual cells in the damaged disc to secrete the ECM and mitigate the degeneration process. To examine this hypothesis, a cartilage anabolic factor, Runx1, was expressed by mRNA through a sophisticated polyamine-based PEG-polyplex nanomicelle delivery system in the damaged disc in a rat model. The mRNA medicine and polyamine carrier have favorable safety characteristics and biocompatibility for regenerative medicine. The endocytosis of mRNA-loaded polyplex nanomicelles in vitro, mRNA delivery efficacy, hydration content, disc shrinkage, and ECM in the disc in vivo were also examined. The data revealed that the mRNA-loaded polyplex nanomicelle was promptly engulfed by cellular late endosome, then spread into the cytosol homogeneously at a rate of less than 20 min post-administration of the mRNA medicine. The mRNA expression persisted for at least 6-days post-injection in vivo. Furthermore, the Runx1 mRNA delivered by polyplex nanomicelles increased hydration content by ≈43% in the punctured disc at 4-weeks post-injection (wpi) compared with naked Runx1 mRNA administration. Meanwhile, the disc space and ECM production were also significantly ameliorated in the polyplex nanomicelle group. This study demonstrated that anabolic factor administration by polyplex nanomicelle-protected mRNA medicine, such as Runx1, plays a key role in alleviating the progress of DDD, which is an imbalance scenario of disc metabolism. This platform could be further developed as a promising strategy applied to regenerative medicine.

6 January 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
HCHeng-Sheng Chao
Heng-Sheng Chao
CTChiao-Yun Tsai
Chiao-Yun Tsai
CCChung-Wei Chou
Chung-Wei Chou
TSTsu-Hui Shiao
Tsu-Hui Shiao
HHHsu-Chih Huang
Hsu-Chih Huang
YCYuh-Min Chen
Yuh-Min Chen
Low-dose computed tomography (LDCT) has emerged as a standard method for detecting early-stage lung cancer. However, the tedious computer tomography (CT) slide reading, patient-by-patient check, and lack of standard criteria to determine the vague but possible nodule leads to variable outcomes of CT slide interpretation. To determine the artificial intelligence (AI)-assisted CT examination, AI algorithm-assisted CT screening was embedded in the hospital picture archiving and communication system, and a 200 person-scaled clinical trial was conducted at two medical centers. With AI algorithm-assisted CT screening, the sensitivity of detecting nodules sized 4–5 mm, 6~10 mm, 11~20 mm, and >20 mm increased by 41%, 11.2%, 10.3%, and 18.7%, respectively. Remarkably, the overall sensitivity of detecting varied nodules increased by 20.7% from 67.7% to 88.4%. Furthermore, the sensitivity increased by 18.5% from 72.5% to 91% for detecting ground glass nodules (GGN), which is challenging for radiologists and physicians. The free-response operating characteristic (FROC) AI score was ≥0.4, and the AI algorithm standalone CT screening sensitivity reached >95% with an area under the localization receiver operating characteristic curve (LROC-AUC) of >0.88. Our study demonstrates that AI algorithm-embedded CT screening significantly ameliorates tedious LDCT practices for doctors.

30 November 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
Chin-Yu LinChin-Yu Lin
Chin-Yu Lin
WLWan-Shiun Lou
Wan-Shiun Lou
JCJyh-Chern Chen
Jyh-Chern Chen
KWKuo-Yao Weng
Kuo-Yao Weng
MSMing-Cheng Shih
Ming-Cheng Shih
Mei-Chih WangMei-Chih Wang
Mei-Chih Wang
Microelectrodes for pain management, neural prosthesis or assistances have a huge medical demand, such as the application of pain management chip or retinal prosthesis addressed on age-related macular degeneration (AMD) and the retinitis pigmentosa (RP). Due to lifelong implanted in human body and direct adhesion of neural tissues, the electrodes and associated insulation materials should possess an ideal bio-compatibility, including non-cytotoxicity and no safety concern elicited by immune responses. Our goal intended to develop retinal prosthesis, an electrical circuit chip used for assisting neural electrons transmission on retina and ameliorating the retinal disability. Therefore, based on the ISO 10993 guidance for implantable medical devices, the electrode prosthesis with insulation material has to conduct bio-compatibility assessment including cytotoxicity, hemolysis, (skin) irritation and pathological implantation examinations. In this study, we manufactured inter-digitated electrode (IDE) chips mimic the electrode prosthesis through photolithography. The titanium and platinum composites were deposited onto a silicon wafer to prepare an electric circuit to mimic the electrode used in retinal prosthesis manufacture, which further be encapsulated to examine the bio-compatibility in compliance with ISO 10993 and ASTM guidance specifically for implantable medical devices. Parylene-C, polyimide and silicon carbide were selected as materials for electrode encapsulation in comparison. Our data revealed parylene-C coating showed a significant excellence on bio-insulation and bio-compatibility specifically addressed on implantable neuron stimulatory devices and provided an economic procedure to package the electrode prosthesis. Therefore, parylene C encapsulation should serve as a consideration for future application on retinal prosthesis manufacture and examination.