The controlled transport of colloids in dead-end structures is a key capability that can enable a wide range of applications, such as biochemical analysis, drug delivery, and underground oil recovery. This Letter presents a new trapping mechanism that allows the fast (i.e., within a few minutes) and reversible accumulation of submicron particles within dead-end microgrooves by means of parallel streams with different salinity level. For the first time, particle focusing in dead-end structures is achieved under steady-state gradients. Confocal microscopy analysis and numerical investigations show that the particles are trapped at a flow recirculation region within the grooves due to a combination of diffusiophoresis transport and hydrodynamic effects. Counterintuitively, the particle velocity at the focusing point is not vanishing and, hence, the particles are continuously transported in and out of the focusing point. The accumulation process is also reversible and one can cyclically trap and release the colloids by controlling the salt concentration of the streams via a flow switching valve.
We reveal a physical mechanism that enables the preconcentration, sorting, and characterization of charged polystyrene nanobeads and liposomes dispersed in a continuous flow within a straight micron-sized channel. Initially, a single Ψ-junction microfluidic chip is used to generate a steady-state salt concentration gradient in the direction perpendicular to the flow. As a result, fluorescent nanobeads dispersed in the electrolyte solutions accumulate into symmetric regions of the channel, appearing as two distinct symmetric stripes when the channel is observed from the top via epi-fluorescence microscopy. Depending on the electrolyte flow configuration and, thus, the direction of the salt concentration gradient field, the fluorescent stripes get closer to or apart from each other as the distance from the inlet increases. Our numerical and experimental analysis shows that although nanoparticle diffusiophoresis and hydrodynamic effects are involved in the accumulation process, diffusio-osmosis along the top and bottom channel walls plays a crucial role in the observed particles dynamics. In addition, we developed a proof-of-concept double Ψ-junction microfluidic device that exploits this accumulation mechanism for the size-based separation and size detection of nanobeads as well as for the measurement of zeta potential and charged lipid composition of liposomes under continuous flow settings. This device is also used to investigate the effect of fluid-like or gel-like states of the lipid membranes on the liposome diffusiophoretic response. The proposed strategy for solute-driven manipulation and characterization of colloids has great potential for microfluidic bioanalytical testing applications, including bioparticle preconcentration, sorting, sensing, and analysis.
We design a suspension of ultra-soft, deflated PDMS microcapsules, which mimic the deformation of red blood cells when propagated at constant flow rate in confined capillary tubes, to serve as a valuable tool to investigate microhaemodynamics.
The delivery of colloidal particles in dead-end microstructures is very challenging, since these geometries do not allow net flows of particle-laden fluids; meanwhile, diffusive transport is slow and inefficient. Recently, we introduced a novel particle manipulation strategy, based on diffusiophoresis, whereby the salt concentration gradient between parallel electrolyte streams in a microgrooved channel induces the rapid (i.e., within minutes) and reversible accumulation, retention, and removal of colloidal particles in the microgrooves. In this study, we investigated the effects of salt contrast and groove depth on the accumulation process in silicon microgrooves and determined the experimental conditions that lead to a particle concentration peak of more than four times the concentration in the channel bulk. Also, we achieved an average particle concentration in the grooves of more than twice the concentration in the flowing streams and almost 2 orders of magnitude larger than the average concentration in the grooves in the absence of a salt concentration gradient. Analytical sufficient and necessary conditions for particle accumulation are also derived. Finally, we successfully tested the accumulation process in polydimethylsiloxane microgrooved channels, as they are less expensive to fabricate than silicon microgrooved substrates. The controlled and enhanced accumulation of colloidal particles in dead-end structures by solute concentration gradients has potential applications in soft matter and living systems, such as drug delivery, synthetic biology, and on-chip diagnostics.
The dynamics of blood flow in the smallest vessels and passages of the human body, where the cellular character of blood becomes prominent, plays a dominant role in the transport and exchange of solutes. Recent studies have revealed that the microhaemodynamics of a vascular network is underpinned by its interconnected structure, and certain structural alterations such as capillary dilation and blockage can substantially change blood flow patterns. However, for extravascular media with disordered microstructure (e.g. the porous intervillous space in the placenta), it remains unclear how the medium’s structure affects the haemodynamics. Here, we simulate cellular blood flow in simple models of canonical porous media representative of extravascular biological tissue, with corroborative microfluidic experiments performed for validation purposes. For the media considered here, we observe three main effects: first, the relative apparent viscosity of blood increases with the structural disorder of the medium; second, the presence of red blood cells (RBCs) dynamically alters the flow distribution in the medium; third, symmetry breaking introduced by moderate structural disorder can promote more homogeneous distribution of RBCs. Our findings contribute to a better understanding of the cell-scale haemodynamics that mediates the relationship linking the function of certain biological tissues to their microstructure.