The potential of utilizing doubly-fed induction generator (DFIG)-based wind farms to improve power system damping performance and to enhance small signal stability has been proposed by many researchers. However, the simultaneous coordinated tuning of a DFIG power oscillation damper (POD) with other damping controllers is rarely involved. A simultaneous robust coordinated multiple damping controller design strategy for a power system incorporating power system stabilizer (PSS), static var compensator (SVC) POD and DFIG POD is presented in this paper. This coordinated damping control design strategy is addressed as an eigenvalue-based optimization problem to increase the damping ratios of oscillation modes. Both local and inter-area electromechanical oscillation modes are intended in the optimization design process. Wide-area phasor measurement unit (PMU) signals, selected by the joint modal controllability/ observability index, are utilized as SVC and DFIG POD feedback modulation signals to suppress inter-area oscillation modes. The robustness of the proposed coordinated design strategy is achieved by simultaneously considering multiple power flow situations and operating conditions. The recently proposed Grey Wolf optimizer (GWO) algorithm is adopted to efficiently optimize the parameter values of multiple damping controllers. The feasibility and effectiveness of the proposed coordinated design strategy are demonstrated through frequency-domain eigenvalue analysis and nonlinear time-domain simulation studies in two modified benchmark test systems. Moreover, the dynamic response simulation results also validate the robustness of the recommended coordinated multiple damping controllers under various system operating conditions.
From a mathematical point of view, the evaluation of the open loop scheme of electromagnetic loop network is a multi-objective optimization problem. This paper combines subjective and objective weighting methods and takes fully into account the evaluation elements of electromagnetic loop network open-loop, and proposes an evaluation method based on comprehensive weighting for open-loop schemes of electromagnetic loop network. Firstly, the opening principle and mechanism of electromagnetic loop network are analyzed. On this basis, the comprehensive evaluation index system of the open loop scheme of the electromagnetic loop network is established by taking into account safety and stability of the system, current limiting effect and economic operation and so on. Then, in order to calculate the subjective and objective weight coefficient by using the analytic hierarchy process (AHP) and the coefficient of variation method and through the comprehensive evaluation calculation to obtain a comprehensive index to evaluate the advantages and disadvantages of the open-loop scheme. The rationality and validity of the method presented in this paper are verified through the example analysis of an actual grid in one province and the simulation analysis by using PSASP.