Most modern world appliances have an intermediate AC to DC rectifier, whether used for DC (LEDs, chargers) or applications with internal motors (refrigerator, washing machine). The conventional rectifiers distort the power factor and introduce harmonics in the grid. Multilevel rectifiers (MLR) with power factor correction (PFC) and high load handling capability have gained much research focus, and numerous topologies have been reported. However, most of them either fail to maintain the unity power factor (UPF) across the entire power range or to maintain UPF employ external circuitry and control. Further, capacitor voltage balancing is another major issue in MLR. In this regard, this paper proposes a sensor less self-balanced MLR topology that maintains UPF in all operating conditions. Experimental results have been presented for validation of the claims mentioned above of the implemented topology. A quantitative comparison with the recent literature has also been included.
Due to its voltage-fed nature and capacitive output filter, rear-end rectifier (RER) of series-parallel resonant converters with capacitive filters draw discontinuous currents. Not only simple and elegant techniques such as Fundamental Harmonic Approximation (FHA) analysis, but also time domain, state space and state-plane approaches also fail to model such converters with reduced labor. A recent study introduced technique to restore the simplicity of FHA analysis concerning such converters. Therefore, detailed discussion of available FHA modelling techniques in relation to series-parallel resonant converters with capacitive filters and their comparison is presented in this paper.
Self-sustained microgrid (MG) carries the potential to replicate a conventional grid network with a smooth and robust control scheme to generate and disseminate power with the integration of diverse renewable sources by employing the voltage source inverter (VSI). The power generation capability is the primary function of VSI in an inverter-based distributed generation (DG). In addition, it is also operated to perform the task of demand-side management with the utilization of the conservation voltage reduction (CVR) strategy. In a conventional distribution network, the CVR strategy is exploited by voltage deduction within permissible range with the support of open-loop schemes, such as tap changers, capacitors, or close-loop schemes, such as supervisory control and data acquisition system. However, the CVR's applicability in a standalone MG is still a viable approach to be delved into and hence, this article intends to employ CVR by utilizing the conventional P-f droop and V-I droop principle in inverter-based DG. The proposed strategy produces voltage compensation according to the degree of voltage or frequency variation and therefore, the degree of voltage reduction is not fixed but it varies with the disturbance. The proposed control mechanism relies on the deviation of the voltage generated by the V-I droop and frequency output provided by the P-f droop during the overloading and peak demand condition. In addition to it, a control methodology is devised to check the coordination between CVR and load shedding strategy to shed load during overloading conditions. The performance testing of the proposed control methodology is being validated through real-time Opal-RT device.
The size of Wide Band Gap (WBG) power electronics based converter is often determined by the inductive component. Therefore, high power density inductor design is required to reduce overall weight and volume of converters. In this paper, the novel nanocrystalline powder core is proposed and designed for a SiC MOSFET based DC/DC boost converter. Finite Element (FE) models of the nanocrystalline powder core inductor and a ferrite core inductor are built to examine the loss and inductance under high-frequency operation. The results show that with the same inductance, the volume of nanocrystalline powder core is smaller than the ferrite core with lower loss.
Estimation of motor torque requires information of motor parameters and becomes crucial to the cases where phase inductance varies with the rotor position. Present paper proposes a simple instantaneous torque estimator for a permanent-magnet brushless dc (PM BLDC) motor drive. Proposed estimator requires information of phase currents from the current sensors and duty ratio applied to the individual phase legs of the VSI. Information of phase inductance is not required. Negligence of phase resistance reduces this estimator to a simplified one with considerable error. Applicability of this estimator even for the sinusoidal phase current supply makes it a general strategy for the estimation of instantaneous motor torque for a PM BLDC motor drive. For the validation of the estimator, torque from the Simulink model of PMSM motor with trapezoidal back-emf is considered as a reference.