Manoj Jose

Mr. Manoj Jose

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2020 in Polymers
Verified
Journal Article
Open access
PDF file
indranil basakindranil basak
indranil basak
GNGudrun Nowicki
Gudrun Nowicki
BRBart Ruttens
Bart Ruttens
DDDerese Desta
Derese Desta
JPJeroen Prooth
Jeroen Prooth
Wim DefermeWim Deferme
Wim Deferme
This paper presents the formulation, inkjet printing, and vacuum forming of a conductive and stretchable polymer, poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS), ink on a stretchable and transparent thermoplastic polyurethane (TPU) substrate. The formulation of the conductive and stretchable ink is achieved by combining PEDOT:PSS with additional solvents, to achieve the right inkjet properties for drop-on-demand (DoD) inkjet printing. A conductive pattern can be printed from the 21 µm orifice on a flexible and stretchable TPU substrate, with a linewidth down to 44 µm. The properties of the printed pattern, in terms of sheet resistance, morphology, transparency, impact of weather conditions, and stretching are investigated and show sheet resistances up to 45 Ohm/sq and transparencies as high as 95%, which is comparable to indium tin oxide (ITO). Moreover, in contrast to ITO, one-time stretching up to 40% can be achieved, increasing the sheet resistance up to 214 Ohm/sq only, showing the great potential of this ink for one-time stretching. Finally, as a proof of this one-time stretching, the printed samples are vacuum formed around a 3D object, still showing sufficient conductivity to be applied as a capacitive touch sensor.

27 January 2021 in ACS Sensors
Verified
Journal Article
Closed access
MJManoj Jose
Manoj Jose
Gilles OudebrouckxGilles Oudebrouckx
Gilles Oudebrouckx
SBSeppe Bormans
Seppe Bormans
PVPaula Veske
Paula Veske
Ronald ThoelenRonald Thoelen
Ronald Thoelen
Wim DefermeWim Deferme
Wim Deferme

23 November 2021 in Advanced Engineering Materials
Verified
Journal Article
Closed access
PDF file
MJManoj Jose
Manoj Jose
SMSatish Kumar Mylavarapu
Satish Kumar Mylavarapu
SBSantosh Kumar Bikkarolla
Santosh Kumar Bikkarolla
JMJarne Machiels
Jarne Machiels
SJSankaran K. J.
Sankaran K. J.
Wim DefermeWim Deferme
Wim Deferme

16 February 2019 in Polymers
Verified
Journal Article
Open access
PDF file
INIda Nuramdhani
Ida Nuramdhani
MJManoj Jose
Manoj Jose
PSPieter Samyn
Pieter Samyn
PAPeter Adriaensens
Peter Adriaensens
BMBenny Malengier
Benny Malengier
Lieva Van langenhoveLieva Van langenhove
Lieva Van langenhove
Conductive polymer PEDOT:PSS, sandwiched between two conductive yarns, has been proven to have capacitive behavior in our textile energy storage devices. Full understanding of its underlying mechanism is still intriguing. The effect of the PEDOT to PSS ratio and the configuration of the electrode yarns are the focus of this study. Three commercial PEDOT:PSS yarns, Clevios P-VP-AI-4083, Ossila AI 4083, and Orgacon ICP 1050, as well as stainless steel and silver-coated polybenzoxazole (Ag/PBO) yarns, in various combinations, were used as solid electrolytes and electrodes, respectively. Analyses with NMR, ICP-OES, TGA, and resistivity measurement were employed to characterize the PEDOT:PSS. The device charge-discharge performance was measured by the Arduino microcontroller. Clevios and Ossila were found to have identical characteristics with a similar ratio, that is, 1:5.26, hence a higher resistivity of 1000 Ω.cm, while Orgacon had a lower PEDOT to PSS ratio, that is, 1:4.65, with a lower resistivity of 0.25–1 Ω.cm. The thermal stability of PEDOT:PSS up to 250 °C was proven. Devices with PEDOT:PSS having lower conductivity, such as Clevios P-VP-AI-4083 or Ossila AI 4083, showed capacitive behavior. For a better charge-discharge profile, it is also suggested that the PEDOT to electrode resistance should be low. These results led to a conclusion that a larger ratio of PEDOT to PSS, having higher resistivity, is more desirable, but further research is needed.

13 February 2018 in Materials
Verified
Journal Article
Open access
PDF file
IVInge Verboven
Inge Verboven
JSJeroen Stryckers
Jeroen Stryckers
VMViktorija Mecnika
Viktorija Mecnika
GVGlen Vandevenne
Glen Vandevenne
MJManoj Jose
Manoj Jose
Wim DefermeWim Deferme
Wim Deferme
To maintain typical textile properties, smart designs of light emitting devices are printed directly onto textile substrates. A first approach shows improved designs for alternating current powder electroluminescence (ACPEL) devices. A configuration with the following build-up, starting from the textile substrate, was applied using the screen printing technique: silver (10 µm)/barium titanate (10 µm)/zinc-oxide (10 µm) and poly(3,4-ethylenedioxythiophene)poly(styrenesulfonate) (10 µm). Textile properties such as flexibility, drapability and air permeability are preserved by implementing a pixel-like design of the printed layers. Another route is the application of organic light emitting devices (OLEDs) fabricated out of following layers, also starting from the textile substrate: polyurethane or acrylate (10–20 µm) as smoothing layer/silver (200 nm)/poly(3,4-ethylenedioxythiophene)poly(styrenesulfonate) (35 nm)/super yellow (80 nm)/calcium/aluminum (12/17 nm). Their very thin nm-range layer thickness, preserving the flexibility and drapability of the substrate, and their low working voltage, makes these devices the possible future in light-emitting wearables.

25 February 2021 in Flexible and Printed Electronics
Verified
Journal Article
Closed access
PDF file
MJManoj Jose
Manoj Jose
MLMarijn Lemmens
Marijn Lemmens
SBSeppe Bormans
Seppe Bormans
Ronald ThoelenRonald Thoelen
Ronald Thoelen
WDWim Deferme
Wim Deferme
Electrical impedance tomography (EIT) is a non-invasive, real-time, continuous imaging technique that has multiple applications in health care. EIT is a realizable technique for radiation-free medical imaging ranging from real-time monitoring of bone fracture repair to lung functioning. This work explores the prospect of printing a wearable bioimpedance sensor on textiles for EIT imaging. Screen printing and stencil printing were applied to fabricate the sensor on the textile substrate and the imaging was carried out with the worn sensor on the human body. The first part of this work focuses on developing a flexible textile sensor in the form of a bracelet to obtain cross-sectional images of the forearm that unravel bone features like shape, size and position. However, body parts such as the thorax have added complexities due to their constantly varying perimeter and uneven shape. It is a significant prerequisite for the wearable sensors to apply to dynamic body parts where irregular shape and continuous volume variations occur. The second part of the paper therefore addresses the fabrication and testing of a stretchable textile-based sensor to address such instances of body dynamicity. The proposed stretchable sensor, worn on the thorax, demonstrates the feasibility of imaging such an uneven and dynamic body part. Although the EIT images are inherently attributed to low resolution, this work shows the prospect of wearable imaging applications in health monitoring. Apart from demonstrating the printed sensor for EIT imaging, this paper shows the image rendering quality dependency over the frequency of the signal and the number of electrodes. This work could initiate further research on wearable EIT based health monitoring devices for real-life scenarios.