Taiwan is located in a subtropical region with high temperatures and humidity. Office spaces are located in air-enclosed rooms in buildings, where doors and windows remain closed and only a central air-conditioning system provides temperature adjustment and ventilation. Most offices in this area have office seating areas, document storage areas on both sides of the office, and multi-function devices, which can cause sick office syndrome in the employees. This study applied environmental monitoring technology to analyze the architectural form and indoor and outdoor air quality to propose improvement strategies addressing indoor temperature, relative humidity and air quality. Quality indices were used created to evaluate the improvement efficiency. The analysis results showed that the indoor temperature and relative humidity in staff seating areas can be effectively improved. The statistical analysis results of improved efficiency for PM2.5, PM10 concentrations and total suspended particulates showed that the average indicator values have been raised from 0.05 to 1.5, 2.45 to 4.02 and 0.91 to 3.54, respectively, for staff seating area and −0.01 to 2.82, 0.15 to 3.91 and 1.25 to 7.25, respectively, for photocopier areas. The ambient air quality of this office space has been significantly improved. This study can serve as an example of air quality improvement in traditional common office spaces.
Urban heat islands and increasing energy consumption in subtropical regions such as Taiwan present substantial challenges, particularly in densely populated areas where traditional green spaces are limited. To address these issues, vertical green systems (VGSs) have emerged as a sustainable solution to improve building energy efficiency and mitigate urban heat. This study investigates the impact of VGSs on building temperature regulation, specifically focusing on the effects of shading density and the distance from the building facade. Two experimental setups were assessed, with VGSs positioned at distances of 50 cm and 100 cm, and shading densities of 70% and 95%. Experiments conducted between May and September 2022, under full sunlight (average temperature of 33 °C), revealed that a VGS with a 95% shading density significantly reduced solar radiation to below 50 W/m2. Additionally, it lowered interior temperatures by 0.5–2.1 °C and decreased surface temperatures by 5–12 °C when positioned 100 cm from the building. The VGS also enhanced temperature stability, maintaining interior temperature fluctuations within 1 °C compared to 4 °C in the control group. These results demonstrate that higher shading densities and increased distances from the building facade optimize temperature control and energy efficiency. The findings offer valuable insights for sustainable urban building design, suggesting that VGSs with greater shading densities and appropriate distances provide significant benefits in reducing solar radiation, surface temperatures, and interior temperature fluctuations.
27 June 2023 in Journal of Measurements in Engineering
Population growth and rapid urban development have led to urbanization, caused environmental problems such as: heat islands and air pollution. The installation of park green space system is widely regarded as effective in alleviating the thermal environment and improving the surrounding air quality. Therefore, this study focuses on parks in highly developed cities, The measurements of terrain and topography were conducted using unmanned aerial vehicles (UAVs) to establish a terrain model. This model was combined with environmental factors such as wind speed, direction, solar radiation, temperature, and soil infiltration were measured to assess the correlation between different landscape elements and the environment in various parks. In addition, an air particulate monitor (Arduino Uno) was developed to measure the contribution of green space systems to urban air pollution. Furthermore, by integrating measurements of multiple factors and employing the Pearson's correlation method and three-dimensional scatter plots, this study explored the relationships between many variables of park. Test results show that 1. The materials of the landscape elements should have moderate thermal conductivity; 2. The moisture content of the soil of grassland should be monitored; 3. To improve the air quality, the correlation between wind speed and wind direction should be considered in the placement of landscape elements.
This study aims to investigate the impact of changes in PM2.5 concentrations on peripheral artery disease (PAD) and respiratory diseases, considering the severe threats to health posed by urbanization and air pollution since the Industrial Revolution. Utilizing a mathematical model, the research analyzes health data collected from the northeastern United States and experimental data collected from metropolitan parks in southern China. The study gathers data on air quality changes and verifies the accuracy of the model through statistical methods to explore the impact on health risks. The results indicate that for every 10 µg/m³ increase in PM2.5 concentration, the number of hospital admissions for PAD patients increases by 0.26%, and emergency visits for respiratory diseases increase by 0.23%, primarily due to acute exacerbations of COPD. These findings not only highlight the negative impact of air pollution on health but also provide a critical basis for relevant departments to formulate response measures to protect public health, particularly for cardiovascular disease patients.