Fiber-optic distributed acoustic sensing (DAS) has proven to be a revolutionary technology for the detection of seismic and acoustic waves with ultralarge scale and ultrahigh sensitivity, and is widely used in oil/gas industry and intrusion monitoring. Nowadays, the single-frequency laser source in DAS becomes one of the bottlenecks limiting its advance. Here, we report a dual-comb–based coherently parallel DAS concept, enabling linear superposition of sensing signals scaling with the comb-line number to result in unprecedented sensitivity enhancement, straightforward fading suppression, and high-power Brillouin-free transmission that can extend the detection distance considerably. Leveraging 10-line comb pairs, a world-class detection limit of 560 fε/√Hz@1 kHz with 5 m spatial resolution is achieved. Such a combination of dual-comb metrology and DAS technology may open an era of extremely sensitive DAS at the fε/√Hz level, leading to the creation of next-generation distributed geophones and sonars.
A novel high performance optical fiber sensor for simultaneous measurement of relative humidity (RH) and temperature based on our newly designed knob-integrated fiber Bragg grating (FBG) is proposed and experimentally demonstrated. The knob-shaped taper followed by an FBG works as a multifunctional joint that not only excites the cladding modes but also recouples the cladding modes reflected by the FBG back into the leading single mode fiber. Polyvinyl alcohol (PVA) film is plated on the fiber surface by dip-coating technique as a humidity-to-refractive index (RI) transducer, and affects the intensity of reflected cladding modes by way of evanescent fields. By monitoring the intensity and wavelength of the reflected cladding modes, the RH and temperature variance can be determined simultaneously. Experimental results show an RH sensitivity of up to 1.2 dB/%RH within an RH range of 30-95%, which is significantly better than previously reported values. And the temperature sensitivity of 8.2 pm/°Ccould be achieved in the temperature range of 25-60°C. A fast and reversible time response has also been demonstrated, enabling to pick up a humidity change as fast as 630 ms. The capability of simultaneous measurement of RH and temperature, the fast response, the reusability and the simple fabrication process make this structure a highly promising sensor for real-time practical RH monitoring applications.
We present a compact microfluidic flowmeter based on Fabry-Perot interferometer (FPI). The FPI was composed by a pair of fiber Bragg grating reflectors and a micro Co2+-doped optical fiber cavity, acting as a “hot-wire” sensor. Microfluidic channels made from commercial silica capillaries were integrated with the FPIs on a chip to realize flow-rate sensing system. By utilizing a tunable pump laser with wavelength of 1480 nm, the proposed flowmeter was experimentally demonstrated. The flow rate of the liquid sample is determined by the induced resonance wavelength shift of the FPI. The effect of the pump power, microfluidic channel scale and temperature on the performance of our flowmeter was investigated. The dynamic response was also measured under different flow-rate conditions. The experimental results achieve a sensitivity of 70 pm/(μL/s), a dynamic range up to 1.1 μL/s and response time in the level of seconds, with a spatial resolution ~200 μm. Such good performance renders the sensor a promising supplementary component in microfluidic biochemical sensing system. Furthermore, simulation modal was built up to analyze the heat distribution of the “hot-wire” cavity and optimize the FPI structure as well.
This article presents a high-sensitivity, quantified, linear, and mediator-free resonator-based microwave biosensor for glucose sensing application. The proposed biosensor comprises an air-bridge-type asymmetrical differential inductor (L) and a center-loaded circular finger-based inter-digital capacitor (C) fabricated on Gallium Arsenide (GaAs) substrate using advanced micro-fabrication technology. The intertwined asymmetrical differential inductor is used to achieve a high inductance value with a suitable Q-factor, and the centralized inter-digital capacitor is introduced to generate an intensified electric field. The designed microwave sensor is optimized to operate at a low resonating frequency that increases the electric field penetration depth and interaction area in the glucose sample. The microwave biosensor is tested with different glucose concentrations (0.3–5 mg/ml), under different ambient temperatures (10–50 °C). The involvement of advanced micro-fabrication technology effectively miniaturized the microwave biosensor (0.006λ0 × 0.005λ0) and enhanced its filling factor. The proposed microwave biosensor demonstrates a high sensitivity of 117.5 MHz/mgmL-1 with a linear response (r2 = 0.9987), good amplitude variation of 0.49 dB/mgmL-1 with a linear response (r2 = 0.9954), and maximum reproducibility of 0.78% at 2 mg/mL. Additionally, mathematical modelling was performed to estimate the dielectric value of the frequency-dependent glucose sample. The measured and analyzed results indicate that the proposed biosensor is suitable for real-time blood glucose detection measurements.
A high-performance towing cable hydrophone array based on an improved ultra-sensitive fiber-optic distributed acoustic sensing system (uDAS) with picostrain sensitivity is demonstrated and tested in sea trial, for the first time. A new composite transducer is designed and optimized to enhance the acoustic pressure sensitivity significantly. A sea trial is carried out to test the performances of such a hydrophone array, including flow noise, underwater acoustic signal capture capacity, beamforming processing and localization of artificial source targets. The array exhibits high sensitivity and low noise floor. An average sensitivity of −129.23 dB re rad/µPa at frequencies from 10 Hz to 1500 Hz has been achieved. The localization at distances of 5 km and 10 km is realized, respectively, validating the excellent remote detection and positioning capability of the hydrophone system. The proposed towing cable system, with high sensitivity, simple structure and remote target localization ability, may pave a way for development of the next generation of high-performance light-weighting hydrophone arrays for towing applications.
A novel optical fiber liquid level sensor based on a hollow core Bragg fiber (HCBF) was proposed and demonstrated. The HCBF was first designed and successfully fabricated with periodic transmission band in the spectrum and a transmission loss of ~3.48 dB/cm. An inline optical fiber liquid-level sensor was fabricated by simply sandwiching a piece of HCBF between two single mode fibers. The sensing performance was experimentally tested. A linear liquid-level sensitivity of ~1.1 dB/mm, and fast response time less than 3s was obtained by the intensity demodulation measurement. The temperature and refractive index cross-sensitivities were also investigated. The experimental results indicate that our proposed structure has tiny temperature and RI dependence, which makes it a promising liquid level sensing platform for different liquids.