Mei-Jywan Syu

Prof. Dr. Mei-Jywan Syu

Department of Chemical Engineering, National Cheng Kung University, Tainan 70101, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2006 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MSMei-Jywan Syu
Mei-Jywan Syu
TCTsung-Chieh Chiu
Tsung-Chieh Chiu
CLChune-You Lai
Chune-You Lai
YCYong-Sheun Chang
Yong-Sheun Chang

1 April 2009 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MSMei-Jywan Syu
Mei-Jywan Syu
YCYu-Sung Chang
Yu-Sung Chang

5 April 2005 in Analytica Chimica Acta
Verified
Journal Article
Closed access
HTHsuan-Ang Tsai
Hsuan-Ang Tsai
MSMei-Jywan Syu
Mei-Jywan Syu

2 April 2016 in Sensors
Verified
Journal Article
Open access
PDF file
WMWei-Jhe Ma
Wei-Jhe Ma
CLChing-Hsing Luo
Ching-Hsing Luo
JLJiun-Ling Lin
Jiun-Ling Lin
SCSin-Houng Chou
Sin-Houng Chou
PCPing-Hung Chen
Ping-Hung Chen
Shin-Chi LaiShin-Chi Lai
Shin-Chi Lai
This paper presents a portable low-power battery-driven bioelectrochemical signal acquisition system for urea detection. The proposed design has several advantages, including high performance, low cost, low-power consumption, and high portability. A LT1789-1 low-supply-voltage instrumentation amplifier (IA) was used to measure and amplify the open-circuit potential (OCP) between the working and reference electrodes. An MSP430 micro-controller was programmed to process and transduce the signals to the custom-developed software by ZigBee RF module in wireless mode and UART in able mode. The immobilized urease sensor was prepared by embedding urease into the polymer (aniline-co-o-phenylenediamine) polymeric matrix and then coating/depositing it onto a MEMS-fabricated Au working electrode. The linear correlation established between the urea concentration and the potentiometric change is in the urea concentrations range of 3.16 × 10−4 to 3.16 × 10−2 M with a sensitivity of 31.12 mV/log [M] and a precision of 0.995 (R2 = 0.995). This portable device not only detects urea concentrations, but can also operate continuously with a 3.7 V rechargeab-le lithium-ion battery (500 mA·h) for at least four days. Accordingly, its use is feasible and even promising for home-care applications.

1 July 2006 in Journal of Chromatography A
Verified
Journal Article
Closed access
MSMei-Jywan Syu
Mei-Jywan Syu
YNYou-Ming Nian
You-Ming Nian
YCYong-Sheun Chang
Yong-Sheun Chang
XLXi-Zhang Lin
Xi-Zhang Lin
SSShu-Chu Shiesh
Shu-Chu Shiesh
TCTse-Chuan Chou
Tse-Chuan Chou

1 August 2005 in Biomaterials
Verified
Journal Article
Closed access
MSMei-Jywan Syu
Mei-Jywan Syu
JDJing-Hong Deng
Jing-Hong Deng
YNYou-Ming Nian
You-Ming Nian
TCTsung-Chieh Chiu
Tsung-Chieh Chiu
AWAn-Hua Wu
An-Hua Wu