Nicolas Muller

Mr. Nicolas Muller


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2016 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
NMNicolas Muller
Nicolas Muller
Samir KouroSamir Kouro
Samir Kouro
MMMariusz Malinowski
Mariusz Malinowski
Christian A. RojasChristian A. Rojas
Christian A. Rojas
MJMarek Jasinski
Marek Jasinski
GEGabriel Estay
Gabriel Estay
Marine energy conversion systems are highlighted among nonconventional renewable energy sources for their availability and energy density. Most marine energy conversion systems are based on multigenerator units or arrays, projected to inject power to the grid in the megawatt range. The current solution for regulating generators and managing power output is the use of two-level voltage-source converters in a back-to-back configuration for each generator. This work presents the model, control scheme, and experimental validation of a configuration, which is able to interface medium-voltage high-power multigenerator marine energy conversion systems to the grid at medium-voltage high-power levels. The configuration is based on a two-step rectifier/boost converter for each generator and a multilevel inverter that merges and manages the multiple power outputs from the multigenerator section of the system. The multilevel inverter is responsible for controlling power flow to the grid and provides regulated medium-voltage high-power injection.

1 February 2018
Verified
Conference Paper
Closed access
NMNicolas Muller
Nicolas Muller
SKSamir Kouro
Samir Kouro
PZPericle Zanchetta
Pericle Zanchetta
Patrick WheelerPatrick Wheeler
Patrick Wheeler
The ever growing participation of modern renewable resources in electric markets has shaken the paradigm of generation-demand constant match. Most modern renewables add intermittent behaviour and high variability to electric markets, forcing other renewables and themselves to perform power curtailment and/or having extra generating units connected to the network to compensate power, voltage and frequency variations. In order to handle this scenario, Energy Storage Systems (ESSs) have risen as enabling technologies capable to provide backup energy to compensate power, voltage and frequency fluctuations and, at the same time, offer additional benefits as ancillary services, peak shaving, load shifting, base load generation, etc. This paper presents a novel bidirectional Partial Power Converter (PPC), as an interface between a Battery ESS (BESS) and a grid-tied Photovoltaic (PV) plant. To obtain a better understanding of the converter, its mathematical model is presented and its operation modes are explained. The main purpose of this configuration is to provide peak shaving capability to a grid-tied PV plant, while providing a high efficiency BESS. Simulation results show the operation of the full system (grid-tied PV plant and BESS), performing peak shaving under a step-down and up in solar irradiation.

13 May 2019 in Energies
Verified
Journal Article
Open access
PDF file
NMNicolas Muller
Nicolas Muller
Samir KouroSamir Kouro
Samir Kouro
PZPericle Zanchetta
Pericle Zanchetta
Patrick WheelerPatrick Wheeler
Patrick Wheeler
GBGustavo Bittner
Gustavo Bittner
FGFrancesco Girardi
Francesco Girardi
This paper presents an analyses of an Energy Storage System (ESS) for grid-tied photovoltaic (PV) systems, in order to harness the energy usually lost due to PV array oversizing. A real case of annual PV power generation analysis is presented to illustrate the existing problem and future solutions. Three PV modeling techniques have been applied to estimate non-measured non-harnessed PV power to provide an ESS energy and power sizing strategy. Moreover, a control strategy to store or release power from the DC-link, without modifying the Maximum Power Point Tracking (MPPT) strategy, is presented. The results show an estimation of the annual power loss caused by oversizing the PV array. The ESS sizing strategy gives insight into not only the energy requirements, but also the power requirements of the system. Simulation results show that the proposed ESS control strategy is capable of harnessing the extra power without modifying the existing power converter of the PV plant nor its control strategy.

7 November 2019 in Energies
Verified
Journal Article
Open access
PDF file
Diana Lopez-CaizaDiana Lopez-Caiza
Diana Lopez-Caiza
Freddy Flores-BahamondeFreddy Flores-Bahamonde
Freddy Flores-Bahamonde
Samir KouroSamir Kouro
Samir Kouro
VSVictor Santana
Victor Santana
NMNicolas Muller
Nicolas Muller
Andrii ChubAndrii Chub
Andrii Chub
Single-stage voltage step-up inverters, such as the Dual Boost Inverter (DBI), have a large operating range imposed by the high step-up voltage ratio, which together with the converter of non-linearities, makes them a challenge to control. This is particularly the case for grid-connected applications, where several cascaded and independent control loops are necessary for each converter of the DBI. This paper presents a global current control method based on a combination of a linear proportional resonant controller and a non-linear sliding mode controller that simplifies the controller design and implementation. The proposed control method is validated using a grid-connected laboratory prototype. Experimental results show the correct performance of the controller and compliance with power quality standards.

12 February 2014 in Advanced Optical Materials
Verified
Journal Article
Open access
PDF file
NMNicolas Muller
Nicolas Muller
JHJakub Haberko
Jakub Haberko
CMCatherine Marichy
Catherine Marichy
FSFrank Scheffold
Frank Scheffold
Unusual network structures are used by F. Scheffold and co-workers as templates for a new type of disordered photonic material. The networks are constructed by 3D tessellation based on numerically generated point patterns with long-range hyperuniform correlations. On page 115, using a combination of direct laser writing lithography and chemical vapor deposition, mesoscale silicon replicas of the disordered networks are created. Optical transmittance measurements show a pronounced gap in the shortwave infrared at λG ≈ 2.6 μm.

1 September 2013
Verified
Conference Paper
Closed access
NMNicolas Muller
Nicolas Muller
Samir KouroSamir Kouro
Samir Kouro
JGJaime Glaria
Jaime Glaria
MMMariusz Malinowski
Mariusz Malinowski
This paper presents a medium-voltage power converter system for the Wave Dragon ocean energy conversion platform. The proposed converter configuration is an alternative to the classic back-to-back low voltage converter implemented in the original prototype. The converter configuration merges several diode rectifiers with boost converters operating with low voltage at the generators side, with a single neutral point clamped converter (NPC) operating at medium-voltage at grid side. The control schemes for generator and grid side converters are analyzed, and simulation results are presented as preliminary validation. The proposed configuration provides a simple and cost-effective interface for wave energy conversion systems with several generators, such as Wave Dragon.