Bearing current problems frequently appear in wind turbine systems, which cause wind turbines the break down and result in very large losses. This paper investigates and compares bearing current problems in three kinds of wind turbine generators, namely doubly-fed induction generator (DFIG), direct-drive permanent magnet synchronous generator (PMSG), and semi-direct-drive PMSG turbines. Common mode voltage (CMV) of converters is introduced firstly. Then stray capacitances of three kinds of generators are calculated and compared through the finite element method. The bearing current equivalent circuits are proposed and simulations of the bearing current are carried out. It is verified that the bearing currents of DFIGs are more serious than the two kinds of PMSG, while common mode current (CMC) of the direct-drive PMSG is much greater than the other two types of wind turbine generators.
With the wide application of pulse width modulation (PWM) technology in motor driving, the bearing current problem has become more and more severe. The most complicated problem in analyzing bearing currents is modeling the equivalent circuit of the bearing and determination of the equivalent parameters of the model. During the process of bearing current breakdown, the bearing undergoes a transition from the capacitor state to the resistor state. The previously used equivalent model, which only consists of a capacitor parallel with a constant resistor, cannot reveal the real breakdown process. In this paper, an improved equivalent bearing model is derived from the waveform analysis of the experiment. The variable breakdown resistance model of the bearing is put forward and the calculation method of the breakdown resistance is given. The circuit simulation results from the variable resistance bearing model were much closer to the results of the experiment than those from the constant resistance model.