Electrocardiogram is a non-invasive, inexpensive, and widely used diagnostic tool for arrhythmia diagnosis in clinics. Deep learning techniques have shown great promise in electrocardiogram signal analysis, enabling automatic and accurate detection of various cardiac arrhythmia. This paper proposes an automated multi-label cardiac arrhythmia classification network based on a convolutional neural network. The network aims to detect and classify 45 different cardiac arrhythmia classes using 12-lead electrocardiogram data. Unlike previous studies, our approach incorporates both the residual structure and channel attention mechanism. Thus, we developed two key schemes to improve classification performance: the Global Channel Attention Block and the Short Residual Block. The Global Channel Attention Block incorporates dilated convolutions to preserve overall features. It focuses on the important characteristics of each arrhythmia class from the original electrocardiogram data during the training process. The Short Residual Block employs a residual structure to enhance classification accuracy. The network’s performance is evaluated using a large-scale 12-lead electrocardiogram database for arrhythmia study on PhysioNet and the 2018 China Physiological Signal Challenge dataset. In particular, the proposed classification network shows the highest scores in average precision, recall, F1 score, area under the receiver operating characteristic, and accuracy compared to existing convolutional neural network-based arrhythmia classification networks in a large-scale 12-lead electrocardiogram database for arrhythmia study on PhysioNet.
14 August 2019 in Journal of Signal Processing Systems
This paper proposes a new simplified degree computationless modified Euclid's algorithm (S-DCME) and its architecture for Reed-Solomon decoders. The proposed S-DCME algorithm uses the new initial conditions, and thus, it can combine the data path for loading initial values and the data path for a switching operation. Hence, the S-DCME algorithm can reduce the number of multiplexers and has high performance compared with the existing DCME algorithm and the RiBM algorithm. The gate count using the MagnaChip HSI 0.25μm standard cell library is 17,800.
Discontinuing mechanical ventilation remains challenging. We developed a machine learning model to predict weaning outcomes using only continuous monitoring parameters obtained from ventilators during spontaneous breathing trials (SBTs). Patients who received mechanical ventilation in the medical intensive care unit at a tertiary university hospital from 2019–2021 were included in this study. During the SBTs, three waveforms and 25 numerical data were collected as input variables. The proposed convolutional neural network (CNN)-based weaning prediction model extracts features from input data with diverse lengths. Among 138 enrolled patients, 35 (25.4%) experienced weaning failure. The dataset was randomly divided into training and test sets (8:2 ratio). The area under the receiver operating characteristic curve for weaning success by the prediction model was 0.912 (95% confidence interval [CI], 0.795–1.000), with an area under the precision-recall curve of 0.767 (95% CI, 0.434–0.983). Furthermore, we used gradient-weighted class activation mapping technology to provide visual explanations of the model’s prediction, highlighting influential features. This tool can assist medical staff by providing intuitive information regarding readiness for extubation without requiring any additional data collection other than SBT data. The proposed predictive model can assist clinicians in making ventilator weaning decisions in real time, thereby improving patient outcomes.
Converting a low dynamic range (LDR) image into a high dynamic range (HDR) image produces an image that closely depicts the real world without requiring expensive devices. Recent deep learning developments can produce highly realistic and sophisticated HDR images. This paper proposes a deep learning method to segment the bright and dark regions from an input LDR image and reconstruct the corresponding HDR image with similar dynamic ranges in the real world. The proposed multi-stage deep learning network brightens bright regions and darkens dark regions, and features with extended brightness range are combined to form the HDR image. Dividing the LDR image into the bright and dark regions effectively implements information on lost over-exposed and under-exposed areas, reconstructing a natural HDR image with color and appearance that is similar to reality. Experimental results confirm that the proposed method achieves an 8.52% higher HDR visual difference predictor (HDR-VDP) and a 41.2% higher log exposure range than current methods. Qualitative evaluation also verifies that the proposed method generates images that are close in quality to the ground truth.
Outpatient detection of total bilirubin levels should be performed regularly to monitor the recurrence of jaundice in hepatobiliary and pancreatic disease patients. However, frequent hospital visits for blood testing are burdensome for patients with poor medical conditions. This study validates a novel deep-learning-based smartphone application for the self-diagnosis of scleral jaundice in such patients. The system predicts total serum bilirubin levels using the deep-learning-based regression analysis of scleral photos taken by the smartphone’s built-in camera. Enrolled patients were randomly assigned to either the training cohort (n = 90, 1034 photos) or the validation cohort (n = 40, 426 photos). The intraclass correlation coefficient value for predicted serum total bilirubin (PSB) derived from the images repeatedly taken at the same time for the same patient showed good reliability (0.86). A strong correlation between measured serum total bilirubin (MSB) and PSB was observed in the subgroup with MSB levels ≥1.5 mg/dL (Spearman rho = 0.70, p < 0.001). The receiver operating characteristic curve for PSB showed that the area under the curve was 0.93, demonstrating good test performance as a predictor of hyperbilirubinemia (p < 0.001). Using a cut-off PSB ≥1.5, the prediction sensitivity of hyperbilirubinemia was 80.0%, with a specificity of 92.6%. Hence, the tool is effective for patient monitoring.