Joon Hyeon Park

Dr. Joon Hyeon Park

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2021 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
JPJoon Hyeon Park
Joon Hyeon Park
MYMin Jae Yang
Min Jae Yang
JKJi Su Kim
Ji Su Kim
BPBumhee Park
Bumhee Park
JKJin Kim
Jin Kim
MSMyung Hoon Sunwoo
Myung Hoon Sunwoo
Outpatient detection of total bilirubin levels should be performed regularly to monitor the recurrence of jaundice in hepatobiliary and pancreatic disease patients. However, frequent hospital visits for blood testing are burdensome for patients with poor medical conditions. This study validates a novel deep-learning-based smartphone application for the self-diagnosis of scleral jaundice in such patients. The system predicts total serum bilirubin levels using the deep-learning-based regression analysis of scleral photos taken by the smartphone’s built-in camera. Enrolled patients were randomly assigned to either the training cohort (n = 90, 1034 photos) or the validation cohort (n = 40, 426 photos). The intraclass correlation coefficient value for predicted serum total bilirubin (PSB) derived from the images repeatedly taken at the same time for the same patient showed good reliability (0.86). A strong correlation between measured serum total bilirubin (MSB) and PSB was observed in the subgroup with MSB levels ≥1.5 mg/dL (Spearman rho = 0.70, p < 0.001). The receiver operating characteristic curve for PSB showed that the area under the curve was 0.93, demonstrating good test performance as a predictor of hyperbilirubinemia (p < 0.001). Using a cut-off PSB ≥1.5, the prediction sensitivity of hyperbilirubinemia was 80.0%, with a specificity of 92.6%. Hence, the tool is effective for patient monitoring.

19 July 2022 in IEEE Access
Verified
Journal Article
Open access
MKMin Cheol Kim
Min Cheol Kim
JPJoon Hyeon Park
Joon Hyeon Park
MSMyung Hoon Sunwoo
Myung Hoon Sunwoo
Demosaicking and denoising are critical for deciding on digital camera performance. However, conventional joint demosaicking and denoising methods use traditional hand-crafted filters for preprocessing and image restoration. Therefore, it is susceptible to noise and can produce many artifacts for images with numerous edges. This paper proposes an end-to-end multi-level wavelet attention convolutional neural network (CNN) that improves image restoration performance by reducing false color artifacts, over-smoothing, and blurring during demosaicing and denoising. In detail, this paper proposes a CNN-based preprocessing method that learns the mosaic image’s inter-color correlation, improving the edge’s color restoration performance. Furthermore, this paper presents a multi-level feature extraction convolutional block using the Haar wavelet-based discrete wavelet transform (DWT) to remove noise from images and restore colors better at the same time. Therefore, it preserves the information of input image and feature maps, learns the correlation between global and local features, improves image restoration performance, and suppresses phenomena such as over-smoothing that tend to occur in DWT-based denoising. The proposed method is an end-to-end network structure with CNN-based preprocessing methods. In experimental results, the proposed method improves PSNR by 3.67 dB and 0.35 dB on average compared with the traditional methods and the CNN-based methods, respectively, for the dataset with many high-frequency components.

15 September 2026 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
JPJoon Hyeon Park
Joon Hyeon Park
HBHyeong Ju Byeon
Hyeong Ju Byeon
KSKyubo Shin
Kyubo Shin
HJHyunJo Jang
HyunJo Jang
JKJongchan Kim
Jongchan Kim
JKJaeSang Ko
JaeSang Ko
Aims: To evaluate agreement between photo-based automated exophthalmometry and manual Hertel exophthalmometry in healthy individuals and patients with non-thyroidal orbital disease, with a deep learning system trained exclusively in thyroid eye disease (TED) cohorts applied without retraining or fine-tuning. Methods: This was a retrospective observational study. A total of 269 individuals were included in the study, including 95 healthy controls and 174 patients with unilateral non-TED orbital pathology. Automated measurements obtained using Glandy EXO from same-day frontal facial photographs were compared with corresponding manual Hertel exophthalmometry measurements. Agreement was assessed using Pearson correlation coefficient (PCC), mean absolute error (MAE), intraclass correlation coefficient (ICC) and Bland-Altman analysis. Diagnostic performance for clinically significant intereye asymmetry (>2.0 mm) was also evaluated. Results: The system showed good agreement with Hertel exophthalmometry in the eyes of healthy controls (PCC 0.80; MAE 0.86 mm; ICC 0.80) as well as the affected (PCC 0.81; MAE 1.41 mm; ICC 0.75) and fellow (PCC 0.76; MAE 1.03 mm; ICC 0.75) eyes of patients. Overall, 84.8% of measurements were within 2.0 mm of the manual Hertel values. The sensitivity, specificity and accuracy of the system for detecting clinically significant intereye asymmetry were 59.6%, 95.0% and 83.3%, respectively. Conclusions: The TED-trained photoexophthalmometry system showed good agreement with Hertel measurements in healthy individuals and patients with non-TED orbital disease. These findings support its use as an adjunct to clinical examination for objective quantification and documentation of globe position.