A ground-state mechanochromic molecule formed into a film exhibited an absorption color change by mechanical pressure. A mechanochromic resin containing the molecule showed a reversible color change from green to yellow upon contact with ethanol.
A localized surface plasmon resonance (LSPR) sensor for hydrogen sulfide (H2S) has been developed by coating a gold nanopattern with zinc oxide (ZnO) film. H2S detection was achieved by monitoring changes in absorbance at a specific wavelength in the LSPR spectrum. The absorbance increased during exposure to H2S and remained constant after H2S ceased. These responses indicate that the sensor can measure the integrated concentrations of H2S. The sensitivity to H2S was enhanced with increasing relative humidity, enabling detection of 0.05–3 ppm H2S within 10 min at 70% relative humidity. The sensor’s sensitivity and LSPR spectrum could be restored by heating it at 500 °C in air. Notably, the sensor did not respond to methyl mercaptan or dimethyl sulfide, demonstrating high selectivity for H2S. This study highlights the potential of the ZnO-deposited LSPR sensor for highly sensitive and selective detection of H2S.
30 September 2026 in Journal of Radiation Protection and Research
Background: Accidents involving radiographic exposure occur worldwide. During inspection, a large amount of X-ray exposure occurs when the operator is near the source. Therefore, understanding the amount of radiation exposure that can occur in an accident during X-ray work is important.Materials and Methods: X-ray spectra of an X-ray computed tomography (CT) system were measured at 50, 100, and 200 kV. Gafchromic film external beam therapy 4 (EBT4) was used to measure direct X-rays from the Be window of the X-ray CT. Directed and scattered X-ray doses were evaluated using a thermoluminescent dosimeter (TLD-100H) (Thermo Fisher Scientific Inc.).Results and Discussion: Characteristic L-X-ray emitted from the tungsten filament of an X-ray CT machine were observed at 8–10 keV in an open-tube X-ray CT system without a metal filter. The dose rate of personal dose equivalent at a depth of 0.07 mm (Hp(0.07)) was 2.0 Sv/min at 3.7 cm from the X-ray source. The results of Hp(10) for the direct and scattered X-rays showed that the maximum was 7.5 mSv/min.Conclusion: It is important to note that exposure levels can become extremely high if work is performed near an X-ray source without realizing that X-rays are being emitted. We recommend the use of interlock functions and alarm-type personal dosimeters to prevent accidental exposure.