Tomoya Tsuji

Tomoya Tsuji

Auto-generated profile, based on publicly available information

Tomoya Tsuji

Nuclear Science Research Institute, Japan Atomic Energy Agency, Ibaraki, Japan

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2024 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
TTTomoya Tsuji
Tomoya Tsuji
HYHiroshi Yoshitomi
Hiroshi Yoshitomi
MKMunehiko Kowatari
Munehiko Kowatari
YTYoshihiko Tanimura
Yoshihiko Tanimura
A 241Am gamma (γ)-ray calibration field that meets the requirements for a γ-ray reference field as specified in the ISO 4037 standard series was established in the Facility of Radiation Standards of the Japan Atomic Energy Agency. The reference air kerma rates were measured using a reference ionization chamber calibrated by the N-80 quality X-ray calibration field of the national metrology standard in Japan and with a correction to account for differences in photon energy due to the calibration field. Conversion coefficients for the 241Am γ-ray calibration field, including those not listed in the ISO 4037 standard series, were calculated based on the measured γ-ray fluence rate spectra.

17 September 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
HLH. Laffolley
H. Laffolley
YTY. Tsubota
Y. Tsubota
TTT. Tsuji
T. Tsuji
FHF. Honda
F. Honda

1 September 2025 in Journal of Radiological Protection
Verified
Journal Article
Closed access
TTTomoya Tsuji
Tomoya Tsuji
HYHiroshi Yoshitomi
Hiroshi Yoshitomi
SNSho Nishino
Sho Nishino
FSFuminobu Sato
Fuminobu Sato
YTYoshihiko Tanimura
Yoshihiko Tanimura
In response to the new operational quantities proposed in ICRU Report 95, we calculated conversion coefficients for monoenergetic photon calibration fields—specifically, the 241Am γ-ray calibration field and the fluorescence x-ray calibration field—both of which are listed in the annex of the ISO 4037 standard series. These coefficients were derived using the measured photon fluence spectrum. Additionally, correction factors for air density were determined for the low-energy fluorescence x-ray calibration field. Both the conversion coefficients and the air density correction factors were found to vary within the standard uncertainty specified by the ISO 4037 series.

30 September 2026 in Journal of Radiation Protection and Research
Verified
Journal Article
Open access
PDF file
NKNoriaki Kataoka
Noriaki Kataoka
TTTomoya Tsuji
Tomoya Tsuji
YTYuki Takimoto
Yuki Takimoto
MKMunehiko Kowatari
Munehiko Kowatari
Background: Accidents involving radiographic exposure occur worldwide. During inspection, a large amount of X-ray exposure occurs when the operator is near the source. Therefore, understanding the amount of radiation exposure that can occur in an accident during X-ray work is important.Materials and Methods: X-ray spectra of an X-ray computed tomography (CT) system were measured at 50, 100, and 200 kV. Gafchromic film external beam therapy 4 (EBT4) was used to measure direct X-rays from the Be window of the X-ray CT. Directed and scattered X-ray doses were evaluated using a thermoluminescent dosimeter (TLD-100H) (Thermo Fisher Scientific Inc.).Results and Discussion: Characteristic L-X-ray emitted from the tungsten filament of an X-ray CT machine were observed at 8–10 keV in an open-tube X-ray CT system without a metal filter. The dose rate of personal dose equivalent at a depth of 0.07 mm (Hp(0.07)) was 2.0 Sv/min at 3.7 cm from the X-ray source. The results of Hp(10) for the direct and scattered X-rays showed that the maximum was 7.5 mSv/min.Conclusion: It is important to note that exposure levels can become extremely high if work is performed near an X-ray source without realizing that X-rays are being emitted. We recommend the use of interlock functions and alarm-type personal dosimeters to prevent accidental exposure.

29 December 2022 in Japanese Journal of Health Physics
Verified
Journal Article
Open access
PDF file
YYYumi Yasuoka
Yumi Yasuoka
HFHiroki Fujita
Hiroki Fujita
TTTomoya Tsuji
Tomoya Tsuji
TTTakakiyo Tsujiguchi
Takakiyo Tsujiguchi
MSMichiya Sasaki
Michiya Sasaki
SHSeiko Hirota
Seiko Hirota

23 July 2026 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
MKM Kowatari
M Kowatari
NKN Kataoka
N Kataoka
MKM Kobayashi
M Kobayashi
TTT Tsuji
T Tsuji
YTY Tanimura
Y Tanimura
This study experimentally evaluates extremity doses from unintentional exposure emitted by handheld X-ray fluorescence (XRF) analyzers. Although handheld XRF devices are widely used for material analysis, quantitative assessments of unintentional exposure remain limited. Mockup experiments were conducted using a Thermo Scientific NITON XLt 797 analyzer and a polymethyl methacrylate hand phantom equipped with radiophotoluminescent glass dosemeters (GD-302M). Spectrometric measurements were performed with a CdTe detector, and photon fluence spectra were unfolded using the MAXED code with Particle and Heavy Ion Transport code System-generated response functions. The mean X-ray energy was 28.4 ± 0.03 keV, with characteristic molybdenum peaks at ~17.5 keV (Kα) and 19.6 keV (Kβ). For a typical 30-s analysis, the estimated personal dose equivalent Hp(0.07) at the point of contact was ~95 μSv. The Hp(0.07) on the dorsal side was roughly one-fifth of the palmar dose. Ambient dose equivalent rates measured directly from the XRF device may reach high enough to set radiation-controlled areas, underscoring the need for strict handling protocols. These findings demonstrate the importance of radiological protection education and awareness when using handheld XRF devices.