Fei Tang

Dr. Fei Tang

Department of Precision Instrument, Tsinghua University, Room 4206, Building 9003, Beijing, China

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2019 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
RFRui Feng
Rui Feng
Fei TangFei Tang
Fei Tang
NZNing Zhang
Ning Zhang
XWXiaohao Wang
Xiaohao Wang

25 November 2014 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
CGCheng’aN Guo
Cheng’aN Guo
Fei TangFei Tang
Fei Tang
JCJin Chen
Jin Chen
XWXiaohao Wang
Xiaohao Wang
SZSichun Zhang
Sichun Zhang
XZXinrong Zhang
Xinrong Zhang

1 September 2019 in Applied Surface Science
Verified
Journal Article
Closed access
YHYigang Huang
Yigang Huang
Fei TangFei Tang
Fei Tang
ZGZheng Guo
Zheng Guo
XWXiaohao Wang
Xiaohao Wang

6 April 2018 in Analytical Chemistry
Verified
Journal Article
Closed access
Fei TangFei Tang
Fei Tang
CGChengan Guo
Chengan Guo
Xiaoxiao MaXiaoxiao Ma
Xiaoxiao Ma
JZJian Zhang
Jian Zhang
YSYuan Su
Yuan Su
ZOZheng Ouyang
Zheng Ouyang

21 May 2008 in Sensors
Verified
Journal Article
Open access
PDF file
Fei TangFei Tang
Fei Tang
XWXiaohao Wang
Xiaohao Wang
DWDongsheng Wang
Dongsheng Wang
JLJunfeng Li
Junfeng Li
A non-invasive glucose measurement system based on the method of metabolic heat conformation (MHC) is presented in this paper. This system consists of three temperature sensors, two humidity sensors, an infrared sensor and an optical measurement device. The glucose level can be deduced from the quantity of heat dissipation, blood flow rate of local tissue and degree of blood oxygen saturation. The methodology of the data process and the measurement error are also analyzed. The system is applied in a primary clinical test. Compared with the results of a commercial automated chemistry analyzer, the correlation coefficient of the collected data from the system is 0.856. Result shows that the correlation coefficient improves when the factor of heat dissipated by evaporation of the skin is added in. A non-invasive method of measuring the blood flow rate of local tissue by heat transmission between skin and contacted conductor is also introduced. Theoretical derivation and numerical simulation are completed as well. The so-called normalized difference mean (NDM) is chosen to express the quantity of the blood flow rate. The correlation coefficient between the blood flow rates by this method and the results of a Doppler blood flow meter is equal to 0.914.

4 October 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ZGZhanxiao Geng
Zhanxiao Geng
Fei TangFei Tang
Fei Tang
YDYadong Ding
Yadong Ding
SLShuzhe Li
Shuzhe Li
XWXiaohao Wang
Xiaohao Wang
Daily continuous glucose monitoring is very helpful in the control of glucose levels for people with diabetes and impaired glucose tolerance. In this study, a multisensor-based, noninvasive continuous glucometer was developed, which can continuously estimate glucose levels via monitoring of physiological parameter changes such as impedance spectroscopy at low and high frequency, optical properties, temperature and humidity. Thirty-three experiments were conducted for six healthy volunteers and three volunteers with diabetes. Results showed that the average correlation coefficient between the estimated glucose profiles and reference glucose profiles reached 0.8314, with a normalized root mean squared error (NRMSE) of 14.6064. The peak time of postprandial glucose was extracted from the glucose profile, and its estimated value had a correlation coefficient of 0.9449 with the reference value, wherein the root mean square error (RMSE) was 6.8958 min. Using Clarke error grid (CEG) analysis, 100% of the estimated glucose values fell in the clinically acceptable zones A and B, and 92.86% fell in zone A. The application of a multisensor-based, noninvasive continuous glucometer and time series analysis can endure the time delay between human physiological parameters and glucose level changes, so as to potentially accomplish noninvasive daily continuous glucose monitoring.