Hepatitis C virus (HCV) accounts for 15%–20% of cases of acute infection, and chronic HCV infection is developed in about 50%–80% of HCV patients. Unfortunately, due to the lack of proper medical care, difficulty in screening for HCV infection, and lack of awareness resulted in chronic HCV infection in 71 million people on a global scale, and about 399,000 deaths in 2016. It is crucial to recognize that the effective use of antiviral medicines can cure more than 95% of HCV infected people. The Global Health Sector Strategy (GHSS) aim is to reduce the new HCV infections and the HCV associated mortality by 90% and 65%, respectively. Therefore, the methods that are simple, yet powerful enough to detect HCV infections with high sensitivity, specificity, and a shorter window period are crucial to restrain the global burden of HCV healthcare. This article focuses on the technologies used for the detection of HCV in clinical specimens.
According to the World Health Organization (WHO), 71 million people were living with Hepatitis C virus (HCV) infection worldwide in 2015. Each year, about 399,000 HCV-infected people succumb to cirrhosis, hepatocellular carcinoma, and liver failure. Therefore, screening of HCV infection with simple, rapid, but highly sensitive and specific methods can help to curb the global burden on HCV healthcare. Apart from the determination of viral load/viral clearance, the identification of specific HCV genotype is also critical for successful treatment of hepatitis C. This critical review focuses on the technologies used for the detection, discrimination, and genotyping of HCV in clinical samples. This article also focuses on advantages and disadvantages of the reported methods used for HCV detection, quantification, and genotyping.
Alzheimer's disease (AD) is a complex neurodegenerative disorder involving multiple cellular and molecular processes. The discovery of drug molecules capable of targeting multiple factors involved in AD pathogenesis would greatly facilitate in improving therapeutic strategies. The repositioning of existing non-toxic drugs could dramatically reduce the time and costs involved in developmental and clinical trial stages. In this study, preliminary screening of 140 FDA approved nervous system drugs by docking suggested the viability of the tricyclic group of antidepressants against three major AD targets, viz. Acetylcholinesterase (AChE), β-secretase (BACE-1), and amyloid β (Aβ) aggregation, with one member, protriptyline, showing highest inhibitory activity. Detailed biophysical assays, together with isothermal calorimetry, fluorescence quenching experiments, kinetic studies and atomic force microscopy established the strong inhibitory activity of protriptyline against all three major targets. The molecular basis of inhibition was supported with comprehensive molecular dynamics simulations. Further, the drug inhibited glycation induced amyloid aggregation, another important causal factor in AD progression. This study has led to the discovery of protriptyline as a potent multi target directed ligand and established its viability as a promising candidate for AD treatment.
Population-based screening of stage 0–I lung cancer is crucial for saving lives. The CIC/CYFRA 21-1 ratio allows the detection of stage I lung cancer with 76.0% sensitivity and 87.5% specificity.
Cardiovascular diseases such as acute myocardial infarction and heart failure accounted for the death of 17.5 million people (31% of all global deaths) in 2015. Monitoring the level of circulating N-terminal proBNP (NT-proBNP) is crucial for the detection of people at risk of heart failure. In this article, we describe a novel ultra-sensitive NT-proBNP test (us-NT-proBNP) that allows the quantification of circulating NT-proBNP in 30 min at 25 °C in the linear detection range of 7.0–600 pg/mL. It is a first report on the application of a fluorescence bead labeled detection antibody, DNA-guided detection method, and glass fiber membrane platform for the quantification of NT-proBNP in clinical samples. Limit of blank, limit of detection, and limit of quantification were 2.0 pg/mL, 3.7 pg/mL, and 7 pg/mL, respectively. The coefficient of variation was found to be less than 10% in the entire detection range of 7–600 pg/mL. The test demonstrated specificity for NT-proBNP without interferences from bilirubin, intra-lipid, biotin, and hemoglobin. The serial dilution test for plasma samples containing various NT-proBNP levels showed the linear decrement in concentration with the regression coefficient of 0.980–0.998. These results indicate that us-NT-proBNP test does not suffer from the interference of the plasma components for the measurement of NT-proBNP in clinical samples.