Mukesh Sonawane

Mr. Mukesh Sonawane


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2017 in Sensors
Verified
Journal Article
Open access
PDF file
KSKeum-Soo Song
Keum-Soo Song
Satish Balasaheb NimseSatish Balasaheb Nimse
Satish Balasaheb Nimse
MSMukesh Sonawane
Mukesh Sonawane
SWShrikant Warkad
Shrikant Warkad
TKTaisun Kim
Taisun Kim
Cardiovascular diseases such as acute myocardial infarction and heart failure accounted for the death of 17.5 million people (31% of all global deaths) in 2015. Monitoring the level of circulating N-terminal proBNP (NT-proBNP) is crucial for the detection of people at risk of heart failure. In this article, we describe a novel ultra-sensitive NT-proBNP test (us-NT-proBNP) that allows the quantification of circulating NT-proBNP in 30 min at 25 °C in the linear detection range of 7.0–600 pg/mL. It is a first report on the application of a fluorescence bead labeled detection antibody, DNA-guided detection method, and glass fiber membrane platform for the quantification of NT-proBNP in clinical samples. Limit of blank, limit of detection, and limit of quantification were 2.0 pg/mL, 3.7 pg/mL, and 7 pg/mL, respectively. The coefficient of variation was found to be less than 10% in the entire detection range of 7–600 pg/mL. The test demonstrated specificity for NT-proBNP without interferences from bilirubin, intra-lipid, biotin, and hemoglobin. The serial dilution test for plasma samples containing various NT-proBNP levels showed the linear decrement in concentration with the regression coefficient of 0.980–0.998. These results indicate that us-NT-proBNP test does not suffer from the interference of the plasma components for the measurement of NT-proBNP in clinical samples.

1 January 2017 in Journal of Virological Methods
Verified
Journal Article
Open access
WCWasun Chantratita
Wasun Chantratita
KSKeum-Soo Song
Keum-Soo Song
CGChoi GunHo
Choi GunHo
VPViroj Pongthanapisith
Viroj Pongthanapisith
NTNipa Thongbaiphet
Nipa Thongbaiphet
TKTaisun Kim
Taisun Kim
In this article, we describe the 6 HCV Genotyping 9G test and its evaluation by using clinical samples and plasmid DNA standards. In tests with 981 plasmid DNA standards, the 6 HCV Genotyping 9G test showed higher than 92.5% sensitivity and 99.4% specificity. The 6 HCV Genotyping 9G test was compared with the VERSANT HCV Genotype 2.0 assay (LiPA 2.0) for detection and discrimination of HCV genotypes in clinical samples. The results of both tests were verified by genomic sequencing. The 6 HCV Genotyping 9G test demonstrated a 100% agreement with the sequencing results, which was higher than LiPA 2.0. These results indicate that the 6 HCV Genotyping 9G test can be a reliable, sensitive, and accurate diagnostic tool for the correct identification of HCV genotypes in clinical specimens. 6 HCV Genotyping 9G test can genotype six HCV types in 1 PCR in 30min after PCR amplification. The 6 HCV Genotyping 9G test, thus provide critical information to physicians and assist them to apply accurate drug regimen for the effective hepatitis C treatment.

1 November 2016 in Journal of Virological Methods
Verified
Journal Article
Closed access
WCWasun Chantratita
Wasun Chantratita
KSKeum-Soo Song
Keum-Soo Song
VPViroj Pongthanapisith
Viroj Pongthanapisith
NTNipa Thongbaiphet
Nipa Thongbaiphet
KAKanokwan Angkanavin
Kanokwan Angkanavin
TKTaisun Kim
Taisun Kim