Charles Batcho

Prof. Charles Batcho

Department of Rehabilitation, Laval University, 1050, Avenue de la Médecine, Quebec, QC G1V0A6, Canada
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2022 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
Armelle-Myriane NgueleuArmelle-Myriane Ngueleu
Armelle-Myriane Ngueleu
BCBarthod Corentin
Barthod Corentin
Krista L. BestKrista L. Best
Krista L. Best
François RouthierFrançois Routhier
François Routhier
Martin J.-D. OtisMartin J.-D. Otis
Martin J.-D. Otis
Charles BatchoCharles Batcho
Charles Batcho
Background: Wearable activity monitors such as ActiGraph monitoring devices are widely used, especially in research settings. Various research studies have assessed the criterion validity of ActiGraph devices for step counting and distance estimation in adults and older adults. Although several studies have used the ActiGraph devices as a reference system for activity monitoring, there is no summarized evidence of the psychometric properties. The main objective of this systematic review was to summarize evidence related to the criterion validity of ActiGraph monitoring devices for step counting and distance estimation in adults and/or older adults. Methods: Literature searches were conducted in six databases (Medline (OVID), Embase, IEEExplore, CINAHL, Engineering Village and Web of Science). Two reviewers independently conducted selection, a quality analysis of articles (using COSMIN and MacDermid’s grids) and data extraction. Results: This review included 21 studies involving 637 participants (age 30.3 ± 7.5 years (for adults) and 82.7 ± 3.3 years (for older adults)). Five ActiGraph devices (7164, GT1M, wGTX +, GT3X +/wGT3X + and wGT3X − BT) were used to collect data at the hip, wrist and ankle to assess various walking and running speeds (ranging from 0.2 m/s to 4.44 m/s) over durations of 2 min to 3 days (13 h 30 mins per day) for step counting and distance estimation. The ActiGraph GT3X +/wGT3X + and wGT3X − BT had better criterion validity than the ActiGraph 7164, wGTX + and GT1M according to walking and running speeds for step counting. Validity of ActiGraph wGT3X + was good for distance estimation. Conclusion: The ActiGraph wGT3X − BT and GT3X +/wGT3X + have good criterion validity for step counting, under certain conditions related to walking speeds, positioning and data processing.

24 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
BDBenjamin Doré
Benjamin Doré
AGAlex Gaudreault
Alex Gaudreault
GEGauthier Everard
Gauthier Everard
JAJohannes Ayena
Johannes Ayena
AAAHMAD ABBOUD
AHMAD ABBOUD
Charles BatchoCharles Batcho
Charles Batcho
Context: This review aimed to synthesize the literature on the acceptability, feasibility, and effectiveness of immersive virtual technologies to promote physical exercise in older people. Method: We performed a literature review, based on four databases (PubMed, CINAHL, Embase, and Scopus; last search: 30 January 2023). Eligible studies had to use immersive technology with participants aged 60 years and over. The results regarding acceptability, feasibility, and effectiveness of immersive technology-based interventions in older people were extracted. The standardized mean differences were then computed using a random model effect. Results: In total, 54 relevant studies (1853 participants) were identified through search strategies. Concerning the acceptability, most participants reported a pleasant experience and a desire to use the technology again. The average increase in the pre/post Simulator Sickness Questionnaire score was 0.43 in healthy subjects and 3.23 in subjects with neurological disorders, demonstrating this technology’s feasibility. Regarding the effectiveness, our meta-analysis showed a positive effect of the use of virtual reality technology on balance (SMD = 1.05; 95% CI: 0.75–1.36; p < 0.001) and gait outcomes (SMD = 0.7; 95% CI: 0.14–0.80; p < 0.001). However, these results suffered from inconsistency and the number of trials dealing with these outcomes remains low, calling for further studies. Conclusions: Virtual reality seems to be well accepted by older people and its use with this population is feasible. However, more studies are needed to conclude its effectiveness in promoting exercise in older people.

28 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Armelle-Myriane NgueleuArmelle-Myriane Ngueleu
Armelle-Myriane Ngueleu
ABAndreanne K. Blanchette
Andreanne K. Blanchette
DMDésirée Maltais
Désirée Maltais
HMHélène Moffet
Hélène Moffet
BMBradford J. McFadyen
Bradford J. McFadyen
Charles BatchoCharles Batcho
Charles Batcho
With the growing interest in daily activity monitoring, several insole designs have been developed to identify postures, detect activities, and count steps. However, the validity of these devices is not clearly established. The aim of this systematic review was to synthesize the available information on the criterion validity of instrumented insoles in detecting postures activities and steps. The literature search through six databases led to 33 articles that met inclusion criteria. These studies evaluated 17 different insole models and involved 290 participants from 16 to 75 years old. Criterion validity was assessed using six statistical indicators. For posture and activity recognition, accuracy varied from 75.0% to 100%, precision from 65.8% to 100%, specificity from 98.1% to 100%, sensitivity from 73.0% to 100%, and identification rate from 66.2% to 100%. For step counting, accuracies were very high (94.8% to 100%). Across studies, different postures and activities were assessed using different criterion validity indicators, leading to heterogeneous results. Instrumented insoles appeared to be highly accurate for steps counting. However, measurement properties were variable for posture and activity recognition. These findings call for a standardized methodology to investigate the measurement properties of such devices.

1 March 2012 in Stroke
Verified
Journal Article
Closed access
Charles BatchoCharles Batcho
Charles Batcho
ATAlan Tennant
Alan Tennant
JTJean-Louis Thonnard
Jean-Louis Thonnard
Background and Purpose—: This study describes the development of a Rasch-built scale measuring activity limitations in stroke patients, named ACTIVLIM-Stroke. Method—: This new Rasch-built measure was constructed based on stroke patients' perceptions of difficulty in performing daily activities. Patients were recruited from inpatient and outpatient rehabilitation departments in Belgium and Benin. A 73-item questionnaire was completed by 204 participants. A random subsample of 83 subjects was given the questionnaire a second time. Data were analyzed using RUMM2030 software. Results—: After successive Rasch analyses, the ACTIVLIM-Stroke questionnaire, a unidimensional and linear 20-item measure of activity limitations, was constructed. All 20 items fulfilled Rasch requirements (overall and individual item fit, category discrimination, invariance, local response independence, and nonredundancy in item difficulty). This simple patient-based scale encompasses a large range of activities related to self-care, transfer, mobility, manual ability, and balance. The ACTIVLIM-Stroke questionnaire exhibited high internal validity, excellent internal consistency, and good crosscultural validity. The test–retest reliability of item difficulty hierarchy (intraclass correlation coefficient=0.99) and patient location (intraclass correlation coefficient=0.92) were both excellent. Furthermore, it showed good external construct validity using correlations with the Functional Independence Measure motor and the Barthel Index and a higher discriminating capacity than either of these widely used indices. Conclusions—: The ACTIVLIM-Stroke questionnaire has good psychometric qualities and provides accurate measures of activity limitations in patients with stroke. It is recommended for evaluating clinical and research interventions in patients with stroke, because it provides a higher discrimination and might be more sensitive to change.

26 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Armelle-Myriane NgueleuArmelle-Myriane Ngueleu
Armelle-Myriane Ngueleu
ABAndreanne K. Blanchette
Andreanne K. Blanchette
Laurent BouyerLaurent Bouyer
Laurent Bouyer
DMDésirée Maltais
Désirée Maltais
BMBradford J. McFadyen
Bradford J. McFadyen
Charles BatchoCharles Batcho
Charles Batcho
Despite the accessibility of several step count measurement systems, count accuracy in real environments remains a major challenge. Microelectromechanical systems and pressure sensors seem to present a potential solution for step count accuracy. The purpose of this study was to equip an insole with pressure sensors and to test a novel and potentially more accurate method of detecting steps. Methods: Five force-sensitive resistors (FSR) were integrated under the heel, the first, third, and fifth metatarsal heads and the great toe. This system was tested with twelve healthy participants at self-selected and maximal walking speeds in indoor and outdoor settings. Step counts were computed based on previously reported calculation methods, individual and averaged FSR-signals, and a new method: cumulative sum of all FSR-signals. These data were compared to a direct visual step count for accuracy analysis. Results: This system accurately detected steps with success rates ranging from 95.5 ± 3.5% to 98.5 ± 2.1% (indoor) and from 96.5 ± 3.9% to 98.0 ± 2.3% (outdoor) for self-selected walking speeds and from 98.1 ± 2.7% to 99.0 ± 0.7% (indoor) and 97.0 ± 6.2% to 99.4 ± 0.7% (outdoor) for maximal walking speeds. Cumulative sum of pressure signals during the stance phase showed high step detection accuracy (99.5 ± 0.7%–99.6 ± 0.4%) and appeared to be a valid method of step counting. Conclusions: The accuracy of step counts varied according to the calculation methods, with cumulative sum-based method being highly accurate.

1 July 2018 in Annals of Physical and Rehabilitation Medicine
Verified
Journal Article
Closed access
NBNatacha Bourget
Natacha Bourget
ADAnne Deblock-Bellamy
Anne Deblock-Bellamy
ABAndreanne K. Blanchette
Andreanne K. Blanchette
Charles BatchoCharles Batcho
Charles Batcho