To combat climate change and meet energy conservation and emission reduction goals, the building sector must adopt low-carbon technologies and low-carbon management methods. To systematically explore existing research areas and track future research trends of carbon emission in the construction stage (CECS), this study conducts a bibliometric and content analysis of CECS studies. 563 relevant publications published between 2000 and 2022 are examined and analyzed using data from the Web of Science (WoS) core collection database. The findings reveal that studies of CECS have evolved through three stages: preliminary exploratory period, stable development period, and rapid development period. In addition, the literature co-citation network and content analysis classify the 13 found co-citation clusters into four knowledge domains: sources definition, data statistics, assessment methods, and carbon reduction strategies. Finally, a knowledge map of CECS studies is presented, outlining significant aspects of research, existing gaps in knowledge, and directions for future study. This work will make it easier for academics and professionals to pinpoint promising areas of study, fill in knowledge gaps, and broaden the scope of existing research on CECS.
A composite concrete column with encased fiber reinforced polymer (FRP) confined concrete cores (EFCCC) is proposed in this paper. The cross-sectional form of the EFCCC column is composed of several orderly arranged FRP confined concrete cores (FCCCs) surrounding a filled core concrete. This novel composite column has several advantages, such as higher compressive capacity, stronger FRP confinement, and ductile response. The compressive experiment is employed to investigate the compressive behavior of the EFCCC column with deferent parameters, such as outside concrete and stirrups. Test results show that the main failure mode of the EFCCC column with and without an outside concrete or stirrups is tensile fracture of the glass fiber reinforced polymer (GFRP) tubes. Compared to a reinforced concrete (RC) column, the strength and ductility of the EFCCC column was obviously improved by 20% and 500%, respectively. A finite element model (FEM) based on the Drucker–Prager (D-P) was developed that can accurately predict the axial compression behavior of the composite column with FRP confined concrete core. The predicted results obtained by using this FEM have excellent agreement with the experimental results.
An innovative pultruded fiber reinforced polymer (FRP)–wood composite (PFWC) column with a lightweight southern pine wood core confined by outer FRP sheets was manufactured using an improved pultrusion process. Axial compression tests with both ends pinned as boundary conditions were employed to investigate the mechanical performance of such PFWC columns under concentric load. Through experimental investigations, the effects of the slenderness ratio on the failure modes and the axial load bearing capacities of the PFWC columns were evaluated. The failure modes showed that the specimens with a slenderness ratio less than 43.2 failed through compressive failure at junctions on FRP sheets, while those with slenderness ratios larger than 57.6 showed global buckling. Strain responses on specimens with different slenderness ratios are consistent with the observed failure modes. Finite element analysis was carried out to validate the experimental results, and satisfactory agreement was found between the failure modes and load–displacement curves. An empirical equation was developed with a new factor taking 0.65 into account to predict the load bearing capacities of the PFWC columns, and good agreement was found.
The plate of a pultruded fiber-reinforced polymer or fiber-reinforced plastic (FRP) profile produced via a pultrusion process is likely to undergo local buckling and cracking along the fiber direction under an external load. In this study, we constructed a pultruded glass-fiber-reinforced polymer-light wood composite (PGWC) profile to explore its mechanical performance. A rectangular cross-sectional PGWC profile was fabricated with a paulownia wood core, alkali-free glass fiber filaments, and unsaturated phthalate resin. Three-point bending and short column axial compression tests were conducted. Then, the stress calculation for the PGWC profile in the bending and axial compression tests was performed using the Timoshenko beam theory and the composite component analysis method to derive the flexural and axial compression rigidity of the profile during the elastic stress stage. The flexural capacity for this type of PGWC profile is 3.3-fold the sum of the flexural capacities of the wood core and the glass-fiber-reinforced polymer (GFRP) shell. The equivalent flexural rigidity is 1.5-fold the summed flexural rigidity of the wood core and GFRP shell. The maximum axial compressive bearing capacity for this type of PGWC profile can reach 1.79-fold the sum of those of the wood core and GFRP shell, and its elastic flexural rigidity is 1.2-fold the sum of their rigidities. These results indicate that in PGWC profiles, GFRP and wood materials have a positive combined effect. This study produced a pultruded composite material product with excellent mechanical performance for application in structures that require a large bearing capacity.
1 January 2016 in Advances in Materials Science and Engineering
This study presented a new form of composite sandwich panels, with steel plates as facesheets and bonded glass fiber-reinforced polymer (GFRP) pultruded hollow square tubes as core. In this novel panel, GFRP and steel were optimally combined to obtain high bending stiffness, strength, and good ductility. Four-point bending test was implemented to analyze the distribution of the stress, strain, mid-span deflection, and the ultimate failure mode. A section transformation method was used to evaluate the stress and the mid-span deflection of the sandwich panels. The theoretical values, experimental results, and FEM simulation values are compared and appeared to be in good agreement. The influence of thickness of steel facesheet on mid-span deflection and stress was simulated. The results showed that the mid-span deflection and stress decreased and the decent speed was getting smaller as the thickness of steel facesheet increases. A most effective thickness of steel facesheet was advised.
A composite concrete-filled glass fiber reinforced polymer (GFRP) tube square column is a new type of composite column, where GFRP is externally wrapped over several GFRP square tubes to form a multicavity GFRP tube, and then concrete is poured inside. External GFRP wrapping methods can be divided into two types: entirely wrapped and strip-type wrapped methods. The former is superior to the latter in terms of performance under stress. However, difficulties are introduced in the construction process of the former, and substantial materials are required to wrap the entire structure. To examine the axial compressive performance for this new type of composite column and the impact of the wrapping method, we designed and fabricated one type of entirely wrapped composite column and two types of strip-type wrapped composite columns with clear spacings of 85 mm and 40 mm, respectively, and performed static axial compression tests. Through tests and numerical simulations, we obtained the failure mode, load–displacement curve, and load–strain curve of the specimen, and analyzed the impact of the externally wrapped GFRP on the mechanical behavior of the composite column. The results show that the composite column reached the peak load before the fracture of the GFRP tube fiber occurred, and the bearing capacity declined sharply to approximately 75% of the peak load after the fiber fractured, then entered a platform section, thereby displaying ductile failure. As the wrapped layers of GFRP strips increased, the load capacity of the specimen exhibited a linear growth tendency. Compared with the performance of the entirely wrapped method, the load capacity of the specimens in the W5040 group declined 9.8% on average, and the peak efficiency of the GFRP strips increased by 50%, thereby indicating that the use of appropriate GFRP layers and strip distance intervals can ensure the appropriate bearing capacity of composite columns and full utilization of GFRP material properties.