A compact log periodic planar dipole UHF array antenna from 500 MHz to 2.2 GHz for partial discharge measurement in power transformers is presented in this paper. The compactness of the designed antenna is achieved by shaping the arms and tuning selected dipole elements of the array to fill the unoccupied areas. Shaped dipole arrangement results in additional capacitance between the antenna elements enhancing the bandwidth. The designed antenna achieves a fractional bandwidth of 126% and the size is (0.495λ0 x 0.63λ0 x 0.0144λ0) at center frequency of 1.35 GHz. The proposed antenna is experimentally validated on FR4 3.2 mm thickness substrate. The measured gain of antenna is 4 ± 0.5 dBi over 800 MHz to 2.2 GHz which provides lower variation in measured partial discharges. The effective antenna height of the proposed antenna is measured to be over 15 mm. The measured return loss is better than 10 dB over the frequency range. Moreover, partial discharge measurements with oil filled test objects demonstrate that the designed antenna can receive partial discharge signals effectively.
The discrimination of inrush currents and internal fault currents in transformers is an important feature of a transformer protection scheme. The harmonic current restrained feature is used in conventional differential relay protection of transformers. A literature survey shows that the discrimination between the inrush currents and internal fault currents is still an area that is open to research. In this paper, the classification of internal fault currents and magnetic inrush currents in the transformer is performed by using an extended Kalman filter (EKF) algorithm. When a transformer is energized under normal conditions, the EKF estimates the primary side winding current and, hence, the absolute residual signal (ARS) value is zero. The ARS value will not be equal to zero for internal fault and inrush phenomena conditions; hence, the EKF algorithm will be used for discriminating the internal faults and inrush faults by keeping the threshold level to the ARS value. The simulation results are compared with the theoretical analysis under various conditions. It is also observed that the detection time of internal faults decreases with the severity of the fault. The results of various test cases using the EKF algorithm are presented. This scheme provides fast protection of the transformer for severe faults.
Demand Response (DR) plays a vital role in a smart grid, helping consumers plan their usage patterns and optimize electricity consumption and also reduce harmonic pollution in a distribution grid without compromising on their needs. The first step of DR is the disaggregation of loads and identifying them individually. The literature suggests that this is accomplished through electric features. Present-day households are using modern power electronic-based nonlinear loads such as LED (Light Emitting Diode) lamps, electronic regulators and digital controllers to reduce the electricity consumption. Furthermore, usage of SMPS (Switched-Mode Power Supply) for computing and mobile phone chargers is increasing in every home. These nonlinear loads, while reducing electricity consumption, also introduce harmonic pollution into the distribution grid. This article presents a deterministic approach to the non-intrusive identification of load patterns using percentage Total Harmonic Distortion (THD) for DR management from a Power Quality perspective. The percentage THD of various combinations of loads is estimated by enhanced dual-spectrum line interpolated FFT (Fast Fourier Transform) with a four-term minimal side-lobe window using a LabVIEW-based hardware setup in real time. The results demonstrate that percentage THD identifies a different combination of loads effectively and advocates alternate load combinations for recommending to the consumer to reduce harmonic pollution in the distribution grid.
Power system harmonics are inevitable in the presence of non-linear loads. The presence of harmonics has a greater impact on the terminal apparatus. Accurate analysis of Power system harmonics plays an important role to have a better mitigation. Windowed Interpolated FFT (WIFFT) based algorithms are gaining importance due to their accurate analysis. The major advantage of WIFFT based algorithms includes reduction in error due to spectral leakage and picket-fence effect. This paper represents the application of improved Hanning window based Interpolated FFT (IFFT) algorithm for harmonic analysis. The proposed algorithm is used to analyze a static simulated signal in MATLAB. The simulation results shows the effectiveness of Hanning window based IFFT compared to Hamming window based IFFT. The algorithm is also used to analyze a dynamic signal simulated in LabVIEW and its potential towards online tracking of a signal.
Advances in power electronics technology have improved the performance and output waveforms of PWM voltage source inverters. Switching frequencies of 2 to 15 kHz with 0.1 mus rise times are common with the current IGBT technology while allowing for power levels over 200 kW. While the high switching speeds and zero switching loss schemes drastically improve the performance of the PWM inverters, the high rate of voltage rise (dv/dt) of 0 to 600 V in less than 0.1 mus has adverse effects on the motor insulation and bearings and deteriorates the waveform quality. Long cables contribute to a damped high frequency ringing due to the distributed nature of the cable leakage inductance and coupling capacitance (L-C) at the motor terminals resulting in over voltages which further stress the motor insulation. Voltage reflection is a function of inverter output pulse rise time and the length of the motor cables, which behave as a transmission line for the inverter output pulses.