Industrial power system consists of several linear and non‐linear loads. The proliferation of non‐linear loads in power system causes the power system harmonics. Passive filters (PFs) are one of the ancient solutions to mitigate the harmonics. Some of the industrial power systems use PFs for harmonic compensation. Owing to dynamic load variation, the PFs are not the appropriate solution for harmonic compensation. To improve the system performance with existing PFs, this study presents the conservative power theory (CPT)‐based hybrid active power filter (HAPF) with Type‐II current controller for compensation of harmonics, reactive power and also the unbalance caused by different linear and non‐linear loads of an industrial power system. In this system, the CPT is used as a harmonic reference generator and Type‐II controller is designed for current control operation. The proposed HAPF overcomes the drawbacks of PFs and performs the compensation tasks effectively. The industrial power system with the proposed HAPF is modelled in MATLAB/Simulink environment and implemented in the real‐time (RT) using OPAL‐RT‐based RT simulator. The RT results are in compliance with IEEE 519‐2014 standard.
This paper proposes a comprehensive methodology for Field-Oriented Control (FOC) with parameter variation analysis for Interior Permanent Magnet Synchronous Machines (IPMSM). The modeling approach for an IPMSM is first presented, followed by a step-by-step procedure for designing a vector-controlled strategy. The formulation is based on a dq-rotating reference frame aligned with the rotor shaft position. A key distinction of this methodology from traditional approaches is that the current controller is designed in the time domain based on desired time constants, while the speed control is formulated within a frequency response domain framework. The proposed hybrid approach enables accurate tuning of the Proportional-Integrator (PI) controllers for both current and speed control loops. Additionally, a parameter variation analysis is conducted to enhance the proposed methodology. The validity region for the design procedure is presented, ensuring that for any wide speed variation of the machine, loop gains are properly tuned. One of the main advantages of the proposed methodology is that it provides a fast, reliable, and accurate technique for implementing IPMSM drive systems. Results from a Controller Hardware-in-the-Loop (C-HIL) setup with an external microcontroller are presented. The comprehensive design approach is validated under two different IPMSM parameter sets, demonstrating its effectiveness.
Power system harmonics are inevitable in the presence of non-linear loads. The presence of harmonics has a greater impact on the terminal apparatus. Accurate analysis of Power system harmonics plays an important role to have a better mitigation. Windowed Interpolated FFT (WIFFT) based algorithms are gaining importance due to their accurate analysis. The major advantage of WIFFT based algorithms includes reduction in error due to spectral leakage and picket-fence effect. This paper represents the application of improved Hanning window based Interpolated FFT (IFFT) algorithm for harmonic analysis. The proposed algorithm is used to analyze a static simulated signal in MATLAB. The simulation results shows the effectiveness of Hanning window based IFFT compared to Hamming window based IFFT. The algorithm is also used to analyze a dynamic signal simulated in LabVIEW and its potential towards online tracking of a signal.
Space vector pulse width modulation (SVPWM) has been extensively utilized in the three-phase voltage source inverters (VSI) for the benefit of fixed switching frequency, full utilization of DC bus voltage and superior control. In recent times, SVPWM technique was applied for active power filter (APF) control application, as the APF is nothing but of a current controlled VSI. The conventional SVPWM based APF has high computational burden due to complex trigonometric calculations and sector identification involved to generate the compensating signal, hence the response time for compensation is slow. In this paper, an improved SVPWM technique based shunt APF is presented based on the effective time concept. The effective time concept eliminates the trigonometric calculations and sector identification, thereby it reduces the computational effort. Simulation results demonstrate the efficacy of the APF with the improved SVPWM based control strategy. The response time for compensation is 0.02sec.
This paper presents a Digital Phase-Locked Loop (PLL) based on the Second Order Generalized Integrator (SOGI). The PLL structure, as well as the SOGI, are carefully described. The integrators of the SOGI are explained in detail in order to emphasize the elimination of an algebraic loop found in continuous time domain PLLs. The main contributions of this paper are to present the design of PLL entirely in z-domain and to present an easy, fast and accurate way to implement a digital PLL based on the SOGI structure. The digital SOGI PLL is implemented in the digital signal processor TMS320F28335. Experimental and simulation results show the efficacy of the digital SOGI PLL to keep synchronized with grid voltage at frequencies 50 and 60 Hz.
30 September 2020 in International Transactions on Electrical Energy Systems