Sulphate corrosion of concrete is a complex chemical and physical process that leads to the destruction of construction elements. Degradation of concrete results from the transportation of sulphate compounds through the pores of exposed elements and their chemical reactions with cementitious material. Sulphate corrosion can develop in all kind of structures exposed to the corrosive environment. The mechanism of the chemical reactions of sulphate ions with concrete compounds is well known and described. Furthermore, the dependence of the compressive strength of standard cubic samples on the duration of their exposure in the sulphate corrosion environment has been described. However, strength tests on standard samples presented in the scientific literature do not provide an answer to the question regarding the measurement methodology and actual distribution of compressive strength in cross-section of reinforced concrete structures exposed to sulphate ions. Since it is difficult to find any description of this type of test in the literature, the authors undertook to conduct them. The ultrasonic method using exponential heads with spot surface of contact with the material was chosen for the measurements of concrete strength in close cross-sections parallel to the corroded surface. The test was performed on samples taken from compartments of a reinforced concrete tank after five years of operation in a corrosive environment. Test measurements showed heterogeneity of strength across the entire thickness of the tested elements. It was determined that the strength of the elements in internal cross-sections of the structure was up to 80% higher than the initial strength. A drop in the mechanical properties of concrete was observed only in the close zone near the exposed surface.
The accepted methods for testing concrete are not favorable for determining its heterogeneity. The interpretation of the compressive strength result as a product of destructive force and cross-section area is burdened with significant understatements. It is assumed erroneously that this is the lowest value of strength at the height of the tested sample. The top layer of concrete floors often crumble, and the strength tested using sclerometric methods does not confirm the concrete class determined using control samples. That is why it is important to test the distribution of compressive strength in a cross-section of concrete industrial floors with special attention to surface top layers. In this study, we present strength tests of borehole material taken from industrial floors using the ultrasonic method with exponential spot heads with a contact surface area of 0.8 mm2 and a frequency of 40 kHz. The presented research project anticipated the determination of strength for samples in various cross-sections at the height of elements and destructive strength in the strength testing machine. It was confirmed that for standard and big borehole samples, it is not possible to test the strength of concrete in the top layer of the floor by destructive methods. This can be done using the ultrasonic method. After the analysis, certain types of distributions of strength across concrete floor thickness were chosen from the completed research program. The gradient and anti-gradient of strength were proposed as the new parameters for the evaluation of floor concrete quality.
The study analyzes the anisotropy effect for ceramic masonry based on experimental tests of samples made of 25 × 12 × 6.5 cm3 solid brick elements with compressive strength fb = 44.1 MPa and cement mortar with compressive strength fm = 10.9 MPa. The samples were loaded in a single plane with a joint angle that varied from the horizontal plane. The load was applied in a vertical direction. The samples were loaded at angles of 90°, 67.5°, 45°, 22.5°, and 0° toward the bed joints. The most unfavourable cases were determined. It was observed that the anisotropy of the masonry significantly influences the load-bearing capacity of the walls depending on the angle of the compressive stresses trajectory. Approximation curves and equations for compressive strength, Young’s modulus, and Poisson’s coefficient were proposed. It was observed that Young’s modulus and Poisson’s ratio will also change depending on the trajectory of compressive stresses as a function of the joint angle. Experimental tests allowed to determine the failure mechanism in prepared specimens. The study allowed to estimate the masonry strength with the load acting at different angles toward the bed joints.
The issue of samples shape and size effect on the destructive strength of concrete returns from time to time because the compliance of conversion factors proposed by various authors is not satisfactory. Modern drilling equipment encourages to take samples from the structure and to conduct tests of concrete compressive strength based on the destruction of cylinders. This paper presents the ultrasound test methodology for determination of ‘d’ conversion factor from samples obtained, e.g., from structure for strength determined on other samples. First, the velocities of longitudinal ultrasound waves were reduced to a fixed base because samples of various sizes from Ø4 to Ø32cm were tested. Regression curves for the tested samples were determined, separately for each size. Based on these, for various ultrasound velocities and various sizes of samples strengths and relations between strengths was calculated. Formulas were given, which allow to convert the strength from sample of any diameter to the different one. The example of ultrasound testing method for the evaluation of mortar strength in joints between bricks was also presented
The study presents the terrestrial laser scanning (TLS) diagnostic of the clay brick masonry arched staircase in a historic building. Based on the measurements of the existing arched stair flights, 1:1 scale experimental models with and without stair treads were made. Strength tests of the models were carried out for different concentrated force locations in relation to the supporting structure. Force, deflections and reaction in the upper support of the run were measured during the tests. The influence of the masonry steps on the curved vault on the load capacity and stiffness of the run structure was analyzed. The conducted experimental investigations showed that the key element responsible for the actual load-bearing capacity and stiffness of this type of stair flights were the treads above the masonry arch.