Hao-Teng Hsu

Dr. Hao-Teng Hsu

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
Po-Lei LeePo-Lei Lee
Po-Lei Lee
SCSheng-Hao Chen
Sheng-Hao Chen
TCTzu-Chien Chang
Tzu-Chien Chang
WLWei-Kung Lee
Wei-Kung Lee
HHHao-Teng Hsu
Hao-Teng Hsu
HCHsiao-Huang Chang
Hsiao-Huang Chang
The motor imagery (MI)-based brain computer interface (BCI) is an intuitive interface that enables users to communicate with external environments through their minds. However, current MI-BCI systems ask naïve subjects to perform unfamiliar MI tasks with simple textual instruction or a visual/auditory cue. The unclear instruction for MI execution not only results in large inter-subject variability in the measured EEG patterns but also causes the difficulty of grouping cross-subject data for big-data training. In this study, we designed an BCI training method in a virtual reality (VR) environment. Subjects wore a head-mounted device (HMD) and executed action observation (AO) concurrently with MI (i.e., AO + MI) in VR environments. EEG signals recorded in AO + MI task were used to train an initial model, and the initial model was continually improved by the provision of EEG data in the following BCI training sessions. We recruited five healthy subjects, and each subject was requested to participate in three kinds of tasks, including an AO + MI task, an MI task, and the task of MI with visual feedback (MI-FB) three times. This study adopted a transformer- based spatial-temporal network (TSTN) to decode the user’s MI intentions. In contrast to other convolutional neural network (CNN) or recurrent neural network (RNN) approaches, the TSTN extracts spatial and temporal features, and applies attention mechanisms along spatial and temporal dimensions to perceive the global dependencies. The mean detection accuracies of TSTN were 0.63, 0.68, 0.75, and 0.77 in the MI, first MI-FB, second MI-FB, and third MI-FB sessions, respectively. This study demonstrated the AO + MI gave an easier way for subjects to conform their imagery actions, and the BCI performance was improved with the continual learning of the MI-FB training process.

13 July 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HCHsiao-Huang Chang
Hsiao-Huang Chang
CHChuan-Chih Hsu
Chuan-Chih Hsu
CCChia-Yuen Chen
Chia-Yuen Chen
WLWai-Keung Lee
Wai-Keung Lee
HHHao-Teng Hsu
Hao-Teng Hsu
Po-Lei LeePo-Lei Lee
Po-Lei Lee
Respiration is a crucial vital sign to indicate acidotic state of human body. In this paper, we have developed a Holo-Hilbert spectral analysis (HHSA)-based approach to detect subject’s respiration frequency from wrist photoplethysmogram (PPG) signals. The HHSA is a two-layer EMD architecture which first decomposes the original signal into intrinsic mode functions and then tries to find additive and multiplicative interactions among the participating components. The HHSA enables frequency-modulated (FM) and amplitude-modulated (AM) features of a signal can be comprehensively presented on a Holo-Hilbert spectrum (HHS). With the help of HHSA, subject’s respiration frequency can be identified on HHS by finding the AM frequency with the most prominent amplitude around the FM frequency of heart rate. The efficacy of the proposed method has been demonstrated in two designed experiments. In the first experiment, 75 subjects with ages ranged from 20–80 years old, and the difference between the detected results of proposed method and the readouts of transthoracic impedance plethysmography is 0.04 ± 0.96 breathes-per-minute (brm). In the second experiment, six subjects were requested to breathe at 6, 12, 18, 24 brm, following the pacing rhythms of a metronome. The difference between detected respiration rates and expected breathing rates is 0.01 ± 0.70 brm. The HHSA-based approach has manifested its capability to extract respiration-induced multiplicative component in PPG signal. It avoids the ambiguity of frequency representation in signal multiplication when using traditional additive decomposition methods.

13 July 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
HHHao-Teng Hsu
Hao-Teng Hsu
WLWai-Keung Lee
Wai-Keung Lee
KSKuo-Kai Shyu
Kuo-Kai Shyu
TYTing-Kuang Yeh
Ting-Kuang Yeh
Chun-Yen ChangChun-Yen Chang
Chun-Yen Chang
Po-Lei LeePo-Lei Lee
Po-Lei Lee
Neural oscillatory activities existing in multiple frequency bands usually represent different levels of neurophysiological meanings, from micro-scale to macro-scale organizations. In this paper, we adopted Holo-Hilbert spectral analysis (HHSA) to study the amplitude-modulated (AM) and frequency-modulated (FM) components in sensorimotor Mu rhythm induced by slow- and fast-rate repetitive movements. The HHSA-based approach is a two-layer empirical mode decomposition architecture, which firstly decomposes the EEG signal into a series of frequency-modulated intrinsic mode functions (IMFs) and then decomposes each frequency-modulated IMF into a set of amplitude-modulated IMFs. With the HHSA, the FM and AM components were incorporated with their instantaneous power to achieve full-informational spectral analysis. We observed that the instantaneous power induced by slow-rate movements was significantly higher than that induced by fast-rate movements (p <; 0.01, Wilcoxon signed rank test). The alpha-band AM frequencies induced by slow-rate movements were higher than those induced by fast-rate movements, while no statistical difference was found in beta-band AM frequencies. In addition, to study the functional coupling between the primary sensorimotor area and other brain regions, spectral coherence was applied and statistical difference was found in frontal area in slow-rate versus fast-rate movements. The discrepancy between slow- and fast-rate movements might be due to the change of motor functional modes from a default mode network to automatic timing with the increase of movement rates. The use of HHSA for oscillatory activity analysis can be an efficient tool to provide informative interaction among different frequency bands.

30 November 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
HHHao-Teng Hsu
Hao-Teng Hsu
KSKuo-Kai Shyu
Kuo-Kai Shyu
CHChuan-Chih Hsu
Chuan-Chih Hsu
LLLung-Hao Lee
Lung-Hao Lee
Po-Lei LeePo-Lei Lee
Po-Lei Lee
Steady-state visual evoked potential (SSVEP) has been used to implement brain-computer interface (BCI) due to its advantages of high information transfer rate (ITR) and high accu-racy. In recent years, owing to the developments of head-mounted device (HMD), the HMD has become a popular device to imple-ment SSVEP–based BCI. However, an HMD with fixed frame rate only can flash at its subharmonic frequencies which limits the available number of stimulation frequencies for SSVEP-based BCI. In order to increase the number of available commands for SSVEP-based BCI, we proposed a phase-approaching (PA) method to generate visual stimulation sequences at user-specified frequency on an HMD. The flickering sequence generated by our PA method (PAS sequence) tries to approximate user-specified stimulation frequency by means of minimizing the difference of accumulated phases between our PAS sequence and the ideal wave of user-specified frequency. The generated sequence of PA method determines the brightness state for each frame to approach the ac-cumulated phase of the ideal wave. The SSVEPs evoked from stim-ulators, driven by PAS sequences, were analyzed using canonical correlation analysis (CCA) to identify user’s gazed target. In this study, a six-command SSVEP-based BCI was designed to operate a flying drone. The ITR and detection accuracy are 36.84 bits/min and 93.30%, respectively.

Verified
Journal Article
Open access
PDF file
Po-Lei LeePo-Lei Lee
Po-Lei Lee
TLTe-Min Lee
Te-Min Lee
WLWei-Keung Lee
Wei-Keung Lee
NCNarisa Nan Chu
Narisa Nan Chu
YSYuri E. Shelepin
Yuri E. Shelepin
HCHsiao-Huang Chang
Hsiao-Huang Chang
Auditory steady-state response (ASSR) is a translational biomarker for several neurological and psychiatric disorders, such as hearing loss, schizophrenia, bipolar disorder, autism, etc. The ASSR is sinusoidal electroencephalography (EEG)/magnetoencephalography (MEG) responses induced by periodically presented auditory stimuli. Traditional frequency analysis assumes ASSR is a stationary response, which can be analyzed using linear analysis approaches, such as Fourier analysis or Wavelet. However, recent studies have reported that the human steady-state responses are dynamic and can be modulated by the subject’s attention, wakefulness state, mental load, and mental fatigue. The amplitude modulations on the measured oscillatory responses can result in the spectral broadening or frequency splitting on the Fourier spectrum, owing to the trigonometric product-to-sum formula. Accordingly, in this study, we analyzed the human ASSR by the combination of canonical correlation analysis (CCA) and Holo-Hilbert spectral analysis (HHSA). The CCA was used to extract ASSR-related signal features, and the HHSA was used to decompose the extracted ASSR responses into amplitude modulation (AM) components and frequency modulation (FM) components, in which the FM frequency represents the fast-changing intra-mode frequency and the AM frequency represents the slow-changing inter-mode frequency. In this paper, we aimed to study the AM and FM spectra of ASSR responses in a 37 Hz steady-state auditory stimulation. Twenty-five healthy subjects were recruited for this study, and each subject was requested to participate in two auditory stimulation sessions, including one right-ear and one left-ear monaural steady-state auditory stimulation. With the HHSA, both the 37 Hz (fundamental frequency) and the 74 Hz (first harmonic frequency) auditory responses were successfully extracted. Examining the AM spectra, the 37 Hz and the 74 Hz auditory responses were modulated by distinct AM spectra, each with at least three composite frequencies. In contrast to the results of traditional Fourier spectra, frequency splitting was seen at 37 Hz, and a spectral peak was obscured at 74 Hz in Fourier spectra. The proposed method effectively corrects the frequency splitting problem resulting from time-varying amplitude changes. Our results have validated the HHSA as a useful tool for steady-state response (SSR) studies so that the misleading or wrong interpretation caused by amplitude modulation in the traditional Fourier spectrum can be avoided.

13 July 2022 in Electronics
Verified
Journal Article
Open access
PDF file
YWYu-Chi Wang
Yu-Chi Wang
PWPofang Wang
Pofang Wang
HPHan-Chi Pan
Han-Chi Pan
CLChuan-Yi Lin
Chuan-Yi Lin
HHHao-Teng Hsu
Hao-Teng Hsu
PLPo-Lei Lee
Po-Lei Lee
Invasive deep brain stimulation has proven to be clinically therapeutic for patients with drug-refractory epilepsy. The aim of this study was to develop a novel transcranial electrical device as a noninvasive stimulation modality for seizure treatment. We fabricated a novel transcranial electrical device and tested it in four swine brains with depth electrodes surgically implanted under neuro-navigation. Stimulation with two high-frequency alternating currents was used to cause an interference envelope. Acute focal epilepsy was induced by a subcortical injection of penicillin and specific anesthesia protocol. The frequency and electric field of the stimulation in the hippocampus were investigated. The two frequencies (2 k and 2.14 kHz) of stimulation successfully caused an envelope of 140 Hz. With 1 mA stimulation, the electric field degraded gradually and induced an in situ electric field of 0.68 mV/mm in the hippocampi. The interference mode transcranial electric stimulation attenuated the originally induced epileptic form discharges. No neuronal or axonal injuries were noted histopathologically after the stimulation. The feasibility and biosafety of our proposed device were preliminarily verified. Future translational research should focus on the electrode deposition and stimulation parameters for a quantitative therapeutic effect.