Open-ended coaxial probes are widely used to gather dielectric properties of biological tissues. Due to the lack of an agreed data acquisition protocol, several environmental conditions can cause inaccuracies when comparing dielectric data. In this work, the effect of a different measurement probe-to-tissue contact pressure was monitored in the frequency range from 0.5 to 20 GHz. Therefore, we constructed a controlled lifting platform with an integrated pressure sensor to exert a constant pressure on the tissue sample during the dielectric measurement. In the pressure range from 7.74 kPa to 77.4 kPa, we observed a linear correlation of % and % per kPa for, respectively, the relative real and imaginary complex permittivity. These values are statistically significant compared with the reported measurement uncertainty. Following the literature in different biology-related disciplines regarding pressure-induced variability in measurements, we hypothesize that these changes originate from squeezing out the interstitial and extracellular fluid. This process locally increases the concentration of membranes, cellular organelles, and proteins in the sensed volume. Finally, we suggest moving towards a standardized probe-to-tissue contact pressure, since the literature has already demonstrated that reprobing at the same pressure can produce repeatable data within a 1% uncertainty interval.
This paper proposes a miniature microwave-microfluidic chip based on continuous microfluidics and a miniature interdigital capacitor (IDC). The novel chip consists of three individually accessible heaters, three platinum temperature sensors and two liquid cooling and mixing zones. The IDC is designed to achieve localized, fast and uniform heating of nanoliter volumes flowing through the microfluidic channel. The heating performance of the IDC located on the novel chip was evaluated using a fluorescent dye (Rhodamine B) diluted in demineralized water on a novel microwave-optical-fluidic (MOF) measurement setup. The MOF setup allows simultaneous microwave excitation of the IDC by means of a custom-made printed circuit board (connected to microwave equipment) placed in a top stage of a microscope, manipulation of liquid flowing through the channel located over the IDC with a pump and optical inspection of the same liquid flowing over the IDC using a fast camera, a light source and the microscope. The designed IDC brings a liquid volume of around 1.2 nL from room temperature to 100 °C in 21 ms with 1.58 W at 25 GHz. Next to the heating capability, the designed IDC can dielectrically sense the flowing liquid. Liquid sensing was evaluated on different concentration of water-isopropanol mixtures, and a reflection coefficient magnitude change of 6 dB was recorded around 8.1 GHz, while the minimum of the reflection coefficient magnitude shifted in the same frequency range for 60 MHz.
13 November 2019 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
The lack of a standardized operating protocol for dielectric measurements of biological tissues makes it difficult to objectively compare reported dielectric properties since these properties are affected by multiple environmental confounders. This work investigates the effect of dehydration on dielectric properties as a function of time at different temperatures. Additionally, it proposes a dehydration mitigating technique. The dielectric properties of porcine liver samples were measured during a 35 minute measurement interval at different temperatures. A first set of six experiments was conducted in standard laboratory conditions. A second set of two experiments was conducted with a modified measurement setup with reduced air flow. Under standard conditions, relative changes in the dielectric properties up to 9% were observed. With the modified setup, the relative change was halved compared to standard conditions. This reduction indicates that the environmental conditions have a considerable influence and that modifying these conditions extends the stability of the dielectric properties over time. For several applications relying on the difference in dielectric properties between healthy and malignant tissue, an error of 9% in measured data is on the same order as the effects of interest. The expected difference in dielectric contrast could be obscured due to dehydration.
This work presents a novel platform conceived as an interconnect box (ICB) that brings high-frequency signals from microwave instruments to consumable lab-on-a-chip devices. The ICB can be connected to instruments with a standard coaxial connector and to consumable chips by introducing a spring-levered interface with elastomer conductive pins. With the spring-system, microwave-microfluidic chips can be mounted reliably on the setup in a couple of seconds. The high-frequency interface within the ICB is protected from the environment by an enclosure having a single slit for mounting the chip. The stability and repeatability of the contact between the ICB and inserted consumable chips are investigated to prove the reliability of the proposed ICB. Given the rapid interconnecting of chips using the proposed ICB, five different interdigital capacitor (IDC) designs having the same sensing area were investigated for dielectric permittivity extraction of liquids. The designed IDCs, embedded in a polydimethylsiloxane (PDMS) channel, were fabricated with a lift-off gold patterning technology on a quartz substrate. Water–Isopropanol (IPA) mixtures with different volume fractions were flushed through the channel over IDCs and sensed based on the measured reflection coefficients. Dielectric permittivity was extracted using permittivity extraction techniques, and fitted permittivity data shows good agreement with literature from 100 to 25 GHz.
A nondestructive complementary split ring resonator (CSRR), working in the 0.5 to 6 GHz frequency range, is presented in this work. Three CSRR designs, on the same 5 mm by 5 mm footprint, with different internal dimensions were designed, fabricated, and measured. The results demonstrate a large shift in resonant frequency, up to 2.544 GHz, over a broad relative permittivity range from 1 to 80, and a large penetration depth, up to 7 mm, into the material under test. Secondly, this work presents a deconvolution-based method to increase the spatial resolution of the presented sensors compared to other sensing structures and algorithms. A conformal mapping function relating the resonant frequency to the relative permittivity was fitted through measurements and the point spread function (PSF) was derived from a known dielectric permittivity distribution. Experimental results demonstrated that the extracted PSF was able to reconstruct the dielectric distribution in six different scenarios. Additionally, a spatial resolution of 2 mm has been established according to the Rayleigh criterion, and objects smaller than the size of the sensor have been reconstructed as well. Objects with a different permittivity values can be distinguished as well. The reconstructed images of the objects have a good signal-to-clutter ratio up to 12.0%, which results from a smooth recovered background, and no spatial offset was present between the original and reconstructed objects.
This work presents the design and evaluation of a planar device for microwave heating of liquids in continuous microfluidics (CMF) made in polydimethylsiloxane (PDMS). It deals with volumes in the µL range, which are of high interest and relevance to biologists and chemists. The planar heater in this work is conceived around a complementary split-ring resonator (CSRR) topology that offers a desired electric field direction to—and interaction with—liquids in a microwell. The designed device on a 0.25 mm thick Rogers RO4350B substrate operates at around 2.5 GHz, while a CMF channel and a 2.45 µL microwell are manufactured in PDMS using the casting process. The evaluation of the performance of the designed heater is conducted using a fluorescent dye, Rhodamine B, dissolved in deionized water. Heating measurements are carried out using 1 W of power and the designed device achieves a temperature of 47 °C on a sample volume of 2.45 µL after 20 s of heating. Based on the achieved results, the CSRR topology has a large potential in microwave heating, in addition to the already demonstrated potential in microwave dielectric sensing, all proving the multifunctionality and reusability of single planar microwave-microfluidic devices.