Open-ended coaxial probes are widely used to gather dielectric properties of biological tissues. Due to the lack of an agreed data acquisition protocol, several environmental conditions can cause inaccuracies when comparing dielectric data. In this work, the effect of a different measurement probe-to-tissue contact pressure was monitored in the frequency range from 0.5 to 20 GHz. Therefore, we constructed a controlled lifting platform with an integrated pressure sensor to exert a constant pressure on the tissue sample during the dielectric measurement. In the pressure range from 7.74 kPa to 77.4 kPa, we observed a linear correlation of % and % per kPa for, respectively, the relative real and imaginary complex permittivity. These values are statistically significant compared with the reported measurement uncertainty. Following the literature in different biology-related disciplines regarding pressure-induced variability in measurements, we hypothesize that these changes originate from squeezing out the interstitial and extracellular fluid. This process locally increases the concentration of membranes, cellular organelles, and proteins in the sensed volume. Finally, we suggest moving towards a standardized probe-to-tissue contact pressure, since the literature has already demonstrated that reprobing at the same pressure can produce repeatable data within a 1% uncertainty interval.
This paper proposes a miniature microwave-microfluidic chip based on continuous microfluidics and a miniature interdigital capacitor (IDC). The novel chip consists of three individually accessible heaters, three platinum temperature sensors and two liquid cooling and mixing zones. The IDC is designed to achieve localized, fast and uniform heating of nanoliter volumes flowing through the microfluidic channel. The heating performance of the IDC located on the novel chip was evaluated using a fluorescent dye (Rhodamine B) diluted in demineralized water on a novel microwave-optical-fluidic (MOF) measurement setup. The MOF setup allows simultaneous microwave excitation of the IDC by means of a custom-made printed circuit board (connected to microwave equipment) placed in a top stage of a microscope, manipulation of liquid flowing through the channel located over the IDC with a pump and optical inspection of the same liquid flowing over the IDC using a fast camera, a light source and the microscope. The designed IDC brings a liquid volume of around 1.2 nL from room temperature to 100 °C in 21 ms with 1.58 W at 25 GHz. Next to the heating capability, the designed IDC can dielectrically sense the flowing liquid. Liquid sensing was evaluated on different concentration of water-isopropanol mixtures, and a reflection coefficient magnitude change of 6 dB was recorded around 8.1 GHz, while the minimum of the reflection coefficient magnitude shifted in the same frequency range for 60 MHz.
In this paper, a miniaturized microwave resonator is designed and fabricated. A loop mode resonance is created when the permittivity difference of the two materials loaded in the two fluidic channels are sufficiently large. A highly concentrated electrical field is generated in a microfluidic channel loaded with deionized water to achieve high sensing spatial resolution within a sensing volume of 45 pL. On-wafer measurements are performed by keeping one channel unloaded as a reference while loading the other channel with different mixtures of isopropanol and deionized water. The acquired microwave-microfluidic measurements confirm that the proposed resonator can resolve changes in the permittivity of the loaded liquid between the values of 3.2 and 42.4, making it promising for applications such as mixing monitoring and flow cytometry.
13 November 2019 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
The lack of a standardized operating protocol for dielectric measurements of biological tissues makes it difficult to objectively compare reported dielectric properties since these properties are affected by multiple environmental confounders. This work investigates the effect of dehydration on dielectric properties as a function of time at different temperatures. Additionally, it proposes a dehydration mitigating technique. The dielectric properties of porcine liver samples were measured during a 35 minute measurement interval at different temperatures. A first set of six experiments was conducted in standard laboratory conditions. A second set of two experiments was conducted with a modified measurement setup with reduced air flow. Under standard conditions, relative changes in the dielectric properties up to 9% were observed. With the modified setup, the relative change was halved compared to standard conditions. This reduction indicates that the environmental conditions have a considerable influence and that modifying these conditions extends the stability of the dielectric properties over time. For several applications relying on the difference in dielectric properties between healthy and malignant tissue, an error of 9% in measured data is on the same order as the effects of interest. The expected difference in dielectric contrast could be obscured due to dehydration.
This paper presents a highly sensitive microwave dielectric sensor for determining glucose concentration using a novel metamaterial-inspired Interdigital Capacitor (IDC)–Complementary Split-Ring Resonator (CSRR) structure. The sensor’s sensitivity is improved by a factor of 80 when used as a one-port impedance-matched structure compared to a conventional two-port configuration. By utilizing a digitally controlled step capacitor, we were able to achieve impedance matching at the two distinct frequencies of 3.69 GHz and 4.38 GHz while conserving the resonant mode of the IDC-CSRR. Both matched frequencies were then used for glucose concentration measurements, resulting in a maximum sensitivity of 8.727 dB/mg/ml and 53.01 kHz/mg/ml. Principal component regression (PCR) was used to predict glucose concentration with R2 of 0.9997 and mean average error (MAE) of only 0.045 mg/ml, achieving a resolution of 0.42 mg/ml, corresponding to the minimum detected concentration difference between the two measured samples. The proposed setup demonstrates substantial improvements over conventional two-port sensors, surpassing the performance of more complex interferometric systems.
5 June 2017 in International Journal of Microwave and Wireless Technologies
This paper reports on a microwave heater at 20 GHz for digital microfluidics. It allows rapid heating of nanoliter fluid samples and simultaneous temperature monitoring by correlating the reflection coefficient of the heater with the temperature dependency of the relative permittivity of the lossy fluid under consideration, in this case demineralized water. Microwave heating was performed with power levels of 20 and 23 dBm at the on-wafer probe tips on samples of 500 nL. Temperature measurements were carried out with a miniaturized type K thermocouple, and a platinum resistor to monitor the reference temperature. Microwave and thermal performances have been characterized using multi-physics software, and measurements obtained with a large signal vector network analyzer showed good agreement with simulated data. An average heating rate of 20 °C/s was observed during the first 4 s of the heating process.