Line impedances estimation is of great importance in power system studies. Different software are used in utilities to calculate line impedances using the line conductor and structure data. The calculated values cannot be reliable due to inaccurate information or change in atmospheric condition. Also, since there is a lack of communication between different departments such as system protection, line construction, etc., a line conductor/structure may be changed while the affected departments are not notified. Most of the impedance estimation methods use phasor measurement units (PMUs) in the protection relays which are connected to protection class current transformers (CTs) that do not provide accurate currents compared to metering class CTs. These methods not only require PMUs in the substations, but also fail to measure zero-sequence voltages and currents due to inadequate zero-sequence components under normal operation. In parallel transmission lines, zero-sequence impedance estimation is even more challenging. This paper introduces a method for estimating the self and mutual zero-sequence impedances for mutually coupled transmission lines using recorded fault data. Extensive simulation and protective relay test results in RSCAD/RTDS indicate that the proposed approach has high accuracy in estimating the self and mutual zero-sequence impedances as well as the fault location in parallel transmission lines.
3 November 2020 in IEEE Transactions on Industry Applications
An interval type-2 fuzzy logic (IT2FL)-based technique is proposed to control the operation of an in-conduit hydropower generator for recapturing waste energy in water pressure reducing valves (PRVs) and generating maximum power. Using an experimental setup, an actual water supply station is simulated for testing the operation and control of the in-conduit generator. The test system includes one hydro-powered generator, two PRVs, and two motor-operated valves (MOVs). An IT2FL method developed in MATLAB is used to control MOVs in order to adjust the customer pressure and maximize the generator efficiency. A prototype hardware setup is developed to produce the voltage set points which control the MOV actuators using the pressures which are measured by transducers and transferred to the IT2FL algorithm via a data acquisition and control system. The generator operational limit is met to avoid any possible damage. The IT2FL control-based algorithm is tested on the hardware-in-the-loop (HIL) setup under various flow and pressure values and compared to type-1 fuzzy logic (T1FL) and existing pseudo algorithms. Also, an economic analysis is carried out using real data of a water booster section in Northern Nevada for justifying the economic benefits of the proposed scheme.