Mehrdad Majidi

Mehrdad Majidi

Auto-generated profile, based on publicly available information

Mehrdad Majidi

Department of Electrical and Biomedical Engineering, University of Nevada, Reno, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MKMasoud Karimi
Masoud Karimi
MMMehrdad Majidi
Mehrdad Majidi
HMHamed MirSaeedi
Hamed MirSaeedi
MAMohammad Mehdi Arefi
Mohammad Mehdi Arefi
MOMohammad Oskuoee
Mohammad Oskuoee
This paper introduces a new application of Deep Belief Network (DBN) as an emerging artificial neural network for recognizing and classifying different partial discharge (PD) patterns. Phase Resolved Partial Discharge (PRPD) technique with different window intervals is used to manipulate three PD types including corona, surface and internal discharges measured in a High Voltage (HV) lab. Four approaches are proposed for extracting features from the raw measured data. In the first approach, the DBN is used as both a feature extractor and a PD classifier. The other three approaches extract discriminatory features using statistical and vector norm based operators to train a DBN classifier. The impact of the various phase windows through the PRPD method on the performance of the trained classifier is evaluated to obtain the best window interval. It is shown that the deep architectures are capable of learning important distinguishable features from PD data without any data preprocessing. This eliminates time-consuming feature extraction processes which produce the hand crafted features. Based on a comparison analysis, when the input data is corrupted by noise levels or no feature extraction technique is used to preprocess the data, the proposed approach outperforms other techniques such as Artificial Neural Networks (ANNs), Fuzzy logic classifiers and Support Vector Machines (SVMs).

25 December 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MMMehrdad Majidi
Mehrdad Majidi
MEMehdi Etezadi-Amoli
Mehdi Etezadi-Amoli
This paper proposes a new impedance-based technique to locate all fault types in distribution networks with/without distributed generators. A new procedure to form an impedance matrix using only series impedances of the distribution lines is introduced. The impedance matrix along with the pre- and during-fault voltage phasors at few buses are used to estimate the injection fault current via least-squares technique. Linear least-squares estimator is utilized if micro-phasor measurement units (μPMUs) are installed along the network. However, a nonlinear least-squares problem solved by Trust-Region-Reflective (TRR) algorithm is used when only the voltage magnitudes are provided by smart meters (SMs). The operation of the standard protective devices in the distribution networks are used to reduce the computational burden of the proposed method. Also, a generalized measurement placement algorithm is studied using the discovered features of the impedance matrix. In addition, the Sobol's sensitivity analysis is conducted to quantify the importance of different input factors on the fault location accuracy. The effectiveness of the proposed method is validated on a real 134-bus, 13.8 kV distribution network under several fault scenarios and noisy measurements.

24 September 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
OGOveis Asgari Gashteroodkhani
Oveis Asgari Gashteroodkhani
MMMehrdad Majidi
Mehrdad Majidi
MEMehdi Etezadi-Amoli
Mehdi Etezadi-Amoli
Line impedances estimation is of great importance in power system studies. Different software are used in utilities to calculate line impedances using the line conductor and structure data. The calculated values cannot be reliable due to inaccurate information or change in atmospheric condition. Also, since there is a lack of communication between different departments such as system protection, line construction, etc., a line conductor/structure may be changed while the affected departments are not notified. Most of the impedance estimation methods use phasor measurement units (PMUs) in the protection relays which are connected to protection class current transformers (CTs) that do not provide accurate currents compared to metering class CTs. These methods not only require PMUs in the substations, but also fail to measure zero-sequence voltages and currents due to inadequate zero-sequence components under normal operation. In parallel transmission lines, zero-sequence impedance estimation is even more challenging. This paper introduces a method for estimating the self and mutual zero-sequence impedances for mutually coupled transmission lines using recorded fault data. Extensive simulation and protective relay test results in RSCAD/RTDS indicate that the proposed approach has high accuracy in estimating the self and mutual zero-sequence impedances as well as the fault location in parallel transmission lines.

1 May 2021 in Electric Power Systems Research
Verified
Journal Article
Closed access
MGM. Ghofrani
M. Ghofrani
MMM. Majidi
M. Majidi

3 November 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
OGOveis Asgari Gashteroodkhani
Oveis Asgari Gashteroodkhani
MMMehrdad Majidi
Mehrdad Majidi
MEMehdi Etezadi-Amoli
Mehdi Etezadi-Amoli
An interval type-2 fuzzy logic (IT2FL)-based technique is proposed to control the operation of an in-conduit hydropower generator for recapturing waste energy in water pressure reducing valves (PRVs) and generating maximum power. Using an experimental setup, an actual water supply station is simulated for testing the operation and control of the in-conduit generator. The test system includes one hydro-powered generator, two PRVs, and two motor-operated valves (MOVs). An IT2FL method developed in MATLAB is used to control MOVs in order to adjust the customer pressure and maximize the generator efficiency. A prototype hardware setup is developed to produce the voltage set points which control the MOV actuators using the pressures which are measured by transducers and transferred to the IT2FL algorithm via a data acquisition and control system. The generator operational limit is met to avoid any possible damage. The IT2FL control-based algorithm is tested on the hardware-in-the-loop (HIL) setup under various flow and pressure values and compared to type-1 fuzzy logic (T1FL) and existing pseudo algorithms. Also, an economic analysis is carried out using real data of a water booster section in Northern Nevada for justifying the economic benefits of the proposed scheme.