Mingming Zhang

Mingming Zhang


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
MZMingming Zhang
Mingming Zhang
TDT Claire Davies
T Claire Davies
SXSheng Quan XIE
Sheng Quan XIE
The aim of this study was to provide a systematic review of studies that investigated the effectiveness of robot-assisted therapy on ankle motor and function recovery from musculoskeletal or neurologic ankle injuries. Thirteen electronic databases of articles published from January, 1980 to June, 2012 were searched using keywords 'ankle*', 'robot*', 'rehabilitat*' or 'treat*' and a free search in Google Scholar based on effects of ankle rehabilitation robots was also conducted. References listed in relevant publications were further screened. Eventually, twenty-nine articles were selected for review and they focused on effects of robot-assisted ankle rehabilitation. Twenty-nine studies met the inclusion criteria and a total of 164 patients and 24 healthy subjects participated in these trials. Ankle performance and gait function were the main outcome measures used to assess the therapeutic effects of robot-assisted ankle rehabilitation. The protocols and therapy treatments were varied, which made comparison among different studies difficult or impossible. Few comparative trials were conducted among different devices or control strategies. Moreover, the majority of study designs met levels of evidence that were no higher than American Academy for Cerebral Palsy (CP) and Developmental Medicine (AACPDM) level IV. Only one study used a Randomized Control Trial (RCT) approach with the evidence level being II. All the selected studies showed improvements in terms of ankle performance or gait function after a period of robot-assisted ankle rehabilitation training. The most effective robot-assisted intervention cannot be determined due to the lack of universal evaluation criteria for various devices and control strategies. Future research into the effects of robot-assisted ankle rehabilitation should be carried out based on universal evaluation criteria, which could determine the most effective method of intervention. It is also essential to conduct trials to analyse the differences among different devices or control strategies.

14 October 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
SYShuaijian Yang
Shuaijian Yang
JCJinhao Cheng
Jinhao Cheng
JSJin Shang
Jin Shang
CHChen Hang
Chen Hang
JQJie Qi
Jie Qi
XJXingyu Jiang
Xingyu Jiang
Surface electromyography (sEMG) can provide multiplexed information about muscle performance. If current sEMG electrodes are stretchable, arrayed, and able to be used multiple times, they would offer adequate high-quality data for continuous monitoring. The lack of these properties delays the widespread use of sEMG in clinics and in everyday life. Here, we address these constraints by design of an adhesive dry electrode using tannic acid, polyvinyl alcohol, and PEDOT:PSS (TPP). The TPP electrode offers superior stretchability (~200%) and adhesiveness (0.58 N/cm) compared to current electrodes, ensuring stable and long-term contact with the skin for recording (>20 dB; >5 days). In addition, we developed a metal-polymer electrode array patch (MEAP) comprising liquid metal (LM) circuits and TPP electrodes. The MEAP demonstrated better conformability than commercial arrays, resulting in higher signal-to-noise ratio and more stable recordings during muscle movements. Manufactured using scalable screen-printing, these MEAPs feature a completely stretchable material and array architecture, enabling real-time monitoring of muscle stress, fatigue, and tendon displacement. Their potential to reduce muscle and tendon injuries and enhance performance in daily exercise and professional sports holds great promise.

4 August 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MZMingming Zhang
Mingming Zhang
SXSheng Quan XIE
Sheng Quan XIE
XLXiaolong Li
Xiaolong Li
GZGuoli Zhu
Guoli Zhu
WMWei Meng
Wei Meng
AVAllan J. Veale
Allan J. Veale
This paper proposes a new adaptive patient-cooperative control strategy for improving the effectiveness and safety of robot-assisted ankle rehabilitation. This control strategy has been developed and implemented on a compliant ankle rehabilitation robot (CARR). The CARR is actuated by four Festo Fluidic muscles located to the calf in parallel, has three rotational degrees of freedom. The control scheme consists of a position controller implemented in joint space and a high-level admittance controller in task space. The admittance controller adaptively modifies the predefined trajectory based on real-time ankle measurement, which enhances the training safety of the robot. Experiments were carried out using different modes to validate the proposed control strategy on the CARR. Three training modes include: 1) a passive mode using a joint-space position controller, 2) a patient-robot cooperative mode using a fixed-parameter admittance controller, and 3) a cooperative mode using a variable-parameter admittance controller. Results demonstrate satisfactory trajectory tracking accuracy, even when externally disturbed, with a maximum normalized root mean square deviation less than 5.4%. These experimental findings suggest the potential of this new patient-cooperative control strategy as a safe and engaging control solution for rehabilitation robots.

25 November 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
BZBin Zhong
Bin Zhong
KGKaiqi Guo
Kaiqi Guo
HYHaoyong Yu
Haoyong Yu
MZMingming Zhang
Mingming Zhang
Gait rehabilitation is essential for chronic stroke patients to regain independent walking ability and quality of life, of which symmetry is regarded as a gold standard of gait quality. In this letter, a cable-driven lower limb exoskeleton powered by series elastic actuators (SEAs) has been developed, and a generalized gait-phase-based assistive strategy has been presented to enhance the gait symmetry of chronic stroke patients in the future. This strategy features a parameterized assistive force generation method that allows individuals customization to achieve more synchronized assistance with their walking gait patterns. A compliant human-robot interaction is guaranteed by SEA, and the exoskeleton exhibits low passive impedance and good transparency. The proposed assistive strategy was evaluated with five able-bodied subjects walking with the assistance from exoskeleton while adding artificial impairments to mimic a pathological gait with deficits (i.e., reduced knee flexion and foot-drop). Experimental results proved its efficacy in enhancing temporal walking gait symmetry to the levels comparable to participants’ normal gait.

5 February 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
PLPing Li
Ping Li
GZGuoli Zhu
Guoli Zhu
MZMingming Zhang
Mingming Zhang
This paper presents a novel linear active disturbance rejection control (LADRC) scheme based on internal model control (IMC) rules and extended state observer (ESO) for high-performance motion control of servo motor systems with input delay and disturbances. The standard IMC (S-IMC) scheme is employed to tune the control gains of LADRC for a specified set-point tracking, as well as a linear ESO to handle internal and external disturbances based on a nominal model. However, due to the limited bandwidth of the ESO and the input delay in the networked control system (NCS), the effect of disturbances cannot be fully eliminated, which may have a significant impact on the tracking accuracy. To overcome these deficiencies, a two-degree-of-freedom IMC (TDOF-IMC) scheme combined with the ESO is introduced to further improve the tracking performance. Moreover, the tracking error dynamics is analyzed through an approximation solution by using sliding variables. The theoretical results show that the uniformly ultimately bounded stability of the system can be guaranteed. Comparative experiments were conducted on a servo motor with NCS and demonstrated the effectiveness of the proposed control approach.

1 December 2017 in Robotics and Autonomous Systems
Verified
Journal Article
Open access
MZMingming Zhang
Mingming Zhang
JCJinghui Cao
Jinghui Cao
GZGuoli Zhu
Guoli Zhu
QMQing Miao
Qing Miao
XZXiangfeng Zeng
Xiangfeng Zeng
SXSheng Quan XIE
Sheng Quan XIE
The novelty of this paper is the adjustable workspace and torque capacity of a compliant ankle rehabilitation robot (CARR). The robot has three rotational degrees of freedom (DOFs) redundantly actuated by four compliant actuators. It suffers from conflicting workspace and actuation torque due to the use of a parallel mechanism and compliant actuators. To address this issue, also considering physical constraints imposed by human users, the CARR is designed with reconfigurability to make a trade-off between workspace and torque capacity for meeting different training requirements. Theoretical analysis indicates that varying kinematic and dynamic performance of the robot can be achieved by reconfiguring the layout of the actuators. Experiments with/without load also demonstrate the validity of the reconfigurable robotic design for practical applications.