Wei Meng

Dr. Wei Meng

School of Information Engineering, Wuhan University of Technology, Wuhan 430070, China
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Mechatronics
Verified
Journal Article
Open access
WMWei Meng
Wei Meng
QLQuan Liu
Quan Liu
ZZZude Zhou
Zude Zhou
QAQingsong Ai
Qingsong Ai
BSBo Sheng
Bo Sheng
SXSheng Quan XIE
Sheng Quan XIE

15 November 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
QAQingsong Ai
Qingsong Ai
DKDa Ke
Da Ke
JZJie Zuo
Jie Zuo
WMWei Meng
Wei Meng
Quan LiuQuan Liu
Quan Liu
SXSheng Quan XIE
Sheng Quan XIE

17 August 2018 in International Journal of Intelligent Robotics and Applications
Verified
Journal Article
Closed access
PDF file
NRNaqash Rehmat
Naqash Rehmat
JZJie Zuo
Jie Zuo
WMWei Meng
Wei Meng
QLQuan Liu
Quan Liu
SXSheng Quan XIE
Sheng Quan XIE
HLHui Liang
Hui Liang

19 October 2016 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
WMWei Meng
Wei Meng
SXSheng Quan XIE
Sheng Quan XIE
QLQuan Liu
Quan Liu
CLCharles Z. Lu
Charles Z. Lu
QAQingsong Ai
Qingsong Ai
Robot-assisted rehabilitation offers benefits, such as repetitive, intensive, and task-specific training, as compared to traditional manual manipulation performed by physiotherapists. In this paper, a robust iterative feedback tuning (IFT) technique for repetitive training control of a compliant parallel ankle rehabilitation robot is presented. The robot employs four parallel intrinsically compliant pneumatic muscle actuators that mimic skeletal muscles for ankle's motion training. A multiple degrees-of-freedom normalized IFT technique is proposed to increase the controller robustness by obtaining an optimal value for the weighting factor and offering a method with learning capacity to achieve an optimum of the controller parameters. Experiments with human participants were conducted to investigate the robustness as well as to validate the performance of the proposed IFT technique. Results show that the normalized IFT scheme will achieve a better and better tracking performance during the robot repetitive control and provides more robustness to the system by adapting to various situations in robotic rehabilitation.

1 February 2021 in ISA Transactions
Verified
Journal Article
Closed access
YXYuanlong Xie
Yuanlong Xie
XZXiaolong Zhang
Xiaolong Zhang
WMWei Meng
Wei Meng
SZShiqi Zheng
Shiqi Zheng
LJLiquan Jiang
Liquan Jiang
SWShuting Wang
Shuting Wang

4 August 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MZMingming Zhang
Mingming Zhang
SXSheng Quan XIE
Sheng Quan XIE
XLXiaolong Li
Xiaolong Li
GZGuoli Zhu
Guoli Zhu
WMWei Meng
Wei Meng
AVAllan J. Veale
Allan J. Veale
This paper proposes a new adaptive patient-cooperative control strategy for improving the effectiveness and safety of robot-assisted ankle rehabilitation. This control strategy has been developed and implemented on a compliant ankle rehabilitation robot (CARR). The CARR is actuated by four Festo Fluidic muscles located to the calf in parallel, has three rotational degrees of freedom. The control scheme consists of a position controller implemented in joint space and a high-level admittance controller in task space. The admittance controller adaptively modifies the predefined trajectory based on real-time ankle measurement, which enhances the training safety of the robot. Experiments were carried out using different modes to validate the proposed control strategy on the CARR. Three training modes include: 1) a passive mode using a joint-space position controller, 2) a patient-robot cooperative mode using a fixed-parameter admittance controller, and 3) a cooperative mode using a variable-parameter admittance controller. Results demonstrate satisfactory trajectory tracking accuracy, even when externally disturbed, with a maximum normalized root mean square deviation less than 5.4%. These experimental findings suggest the potential of this new patient-cooperative control strategy as a safe and engaging control solution for rehabilitation robots.