The development of reliable long-term encapsulation technologies for implantable biomedical devices is of paramount importance for the safe and stable operation of implants in the body over a period of several decades. Conventional technologies based on titanium or ceramic packaging, however, are not suitable for encapsulating microfabricated devices due to their limited scalability, incompatibility with microfabrication processes, and difficulties with miniaturization. A variety of emerging materials have been proposed for encapsulation of microfabricated implants, including thin-film inorganic coatings of Al2O3, HfO2, SiO2, SiC, and diamond, as well as organic polymers of polyimide, parylene, liquid crystal polymer, silicone elastomer, SU-8, and cyclic olefin copolymer. While none of these materials have yet been proven to be as hermetic as conventional metal packages nor widely used in regulatory approved devices for chronic implantation, a number of studies have demonstrated promising outcomes on their long-term encapsulation performance through a multitude of fabrication and testing methodologies. The present review article aims to provide a comprehensive, up-to-date overview of the long-term encapsulation performance of these emerging materials with a specific focus on publications that have quantitatively estimated the lifetime of encapsulation technologies in aqueous environments.
1 August 2011 in IEEE Transactions on Biomedical Engineering
Flexible polymers have gained much attention in the development of low cost, magnetic resonance compatible, and nonfragile implantable medical devices. However, efficacy of the conventional polymer encapsulations containing hybrid interfaces is limited due to their relatively high moisture absorption and unstable interfacial adhesion in aqueous environments. As an alternative, we report on a monolithic encapsulation platform for neuroprosthetic devices using liquid crystal polymers (LCPs), which have a very low degree of moisture absorption (<;0.04%) and a fusion bondable interface. This platform offers monolithic encapsulation by fusion bonding of the hemispherical LCP package lids and LCP-based microelectrode arrays. The package lids were fabricated by thermoforming of the LCP films to provide the desired shape and size for encasing the electronic components and wireless telemetry coils. Fusion-bonded LCP encapsulations were evaluated using electrical leakage current measurements during in vitro soak tests. The measurements were done in both 37°C and 75°C phosphate-buffered saline (PBS) solution and showed that LCP encapsulation was superior and more reliable in PBS than polyimide and parylene-C encapsulations. In addition, LCP-based monolithic encapsulation provided reliable electrical insulation for more than 300 days in both 37°C and 75°C PBS solution.
A novel retinal prosthetic device was developed using biocompatible liquid crystal polymer (LCP) to address the problems associated with conventional metal- and polymer-based devices: the hermetic metal package is bulky, heavy, and labor-intensive, whereas a thin, flexible, and MEMS-compatible polymer-based system is not durable enough for chronic implantation. Exploiting the advantageous properties of LCP such as a low moisture absorption rate, thermobonding, and thermoforming, we fabricate a small, light-weight, long-term reliable retinal prosthesis that can be conformally attached on the eye-surface. A LCP fabrication process using monolithic integration and conformal deformation was established enabling miniaturization and a batch manufacturing process as well as eliminating the need for feed-through technology. The functionality of the fabricated device was tested through wireless operation in saline solution. Its efficacy and implantation stability were verified through in vivo animal tests by measuring the cortical potential and monitoring implanted dummy devices for more than a year, respectively.
Objective . The aim of this study is to evaluate the long-term reliability of a recently presented liquid crystal polymer (LCP) -based retinal prosthesis in vitro as well as in vivo . Because an all-polymer implant introduces another intrinsic leak type due to gas permeation, for which the traditional helium leak test for metallic packages was not designed to quantify, a new method to investigate its durability is required. Approach . We designed and carried out a series of reliability tests specifically for all-polymer implants by quantitatively investigating moisture ingress through various pathways of the polymer surface, and the polymer–polymer and polymer–metal adhesions. Moisture permeation through the bulk material was estimated by analytic calculation, while water ingress through the adhesively sealed LCP–LCP and LCP–metal interfaces was investigated using the separate parts of an electrode array and a package in an accelerated aging condition. In vivo tests were done in rabbits to examine the long-term biocompatibility and implantation stability by fundus observation and optical coherence tomography (OCT) imaging. Main results . The analytic calculation estimated good barrier properties of the LCP. Samples of the LCP-based electrode array failed after 114 days in 87 °C saline as a result of water penetration through the LCP–metal interface. An eye-conformable LCP package survived for 87 days in an accelerated condition at 87 °C. The in vivo results confirmed that no adverse effects were observed around the retina 2.5 years after the implantation of the device. Significance . These long-term evaluation results show the potential for the chronic use of LCP-based biomedical implants to provide an alternative to traditional metallic packages.
1 May 2012 in Investigative Ophthalmology & Visual Science
Purpose.: The purpose of our study is to evaluate the biocompatibility of various polymers used as microelectrode arrays (MEAs) in retinal prostheses through in vitro cytotoxicity testing following a standardized method. Methods.: Three types of polymer-based MEAs were examined: silicone-based platinum, polyimide-based gold and liquid crystal polymer (LCP)-based gold MEAs. The silicone/platinum MEAs were fabricated by a Nd:YAG laser, polyimide/gold MEAs by a semiconductor manufacturing technique, and LCP/gold MEAs by laser micromachining and thermal-bonding process. All experimental procedures followed the International Organization for Standardization (ISO) 10993-5. To obtain the extracts of specimens, 4 g of each type of MEA were eluted by culture media, MEM, for 24 hours. Then, several diluents of extracts, including the original extracts, were applied to a cultured-cell monolayer, L929 fibroblasts. The morphologic changes of cells were analyzed by microscope after 24 and 48 hours of incubation. The quantitative evaluations of cell viability were performed by MTT assay after 24 hours of incubation. Results.: The microscopic evaluations revealed that extracts from polymer-based MEAs did not induce morphologic changes or reduction of cells compared with control irrespective of concentrations of extracts. The MTT assay showed high viability values of approximately 80 to 130% regardless of diluted ratio of extracts from polymer-based MEAs. None of the polymers demonstrated a significant reduction of cell viability when compared with control. Conclusions.: All types of polymer-based MEAs, including silicone/platinum, polyimide/gold, and LCP/gold MEAs, meet the criteria of biocompatibility guided by international standards, ISO 10993-5.