Seung Woo Lee

Prof. Seung Woo Lee

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in Nature Communications
Verified
Journal Article
Open access
PDF file
GBGiorgio Bonmassar
Giorgio Bonmassar
SLSeung Woo Lee
Seung Woo Lee
DFDaniel K. Freeman
Daniel K. Freeman
MPMiloslav Polasek
Miloslav Polasek
SFShelley I. Fried
Shelley I. Fried
JGJohn T. Gale
John T. Gale
Electrical stimulation is currently used to treat a wide range of cardiovascular, sensory and neurological diseases. Despite its success, there are significant limitations to its application, including incompatibility with magnetic resonance imaging, limited control of electric fields and decreased performance associated with tissue inflammation. Magnetic stimulation overcomes these limitations but existing devices (that is, transcranial magnetic stimulation) are large, reducing their translation to chronic applications. In addition, existing devices are not effective for deeper, sub-cortical targets. Here we demonstrate that sub-millimeter coils can activate neuronal tissue. Interestingly, the results of both modelling and physiological experiments suggest that different spatial orientations of the coils relative to the neuronal tissue can be used to generate specific neural responses. These results raise the possibility that micro-magnetic stimulation coils, small enough to be implanted within the brain parenchyma, may prove to be an effective alternative to existing stimulation devices.

2 December 2016 in Science Advances
Verified
Journal Article
Open access
PDF file
SLSeung Woo Lee
Seung Woo Lee
FFFlorian Fallegger
Florian Fallegger
BCBernard D. F. Casse
Bernard D. F. Casse
SFShelley I. Fried
Shelley I. Fried
Magnetic stimulation from cortically implantable microcoils can activate neuronal circuits with high selectivity and reliability.

1 August 2019 in Nano Letters
Verified
Journal Article
Closed access
MGMehran Ganji
Mehran Ganji
APAngelique C. Paulk
Angelique C. Paulk
JYJimmy C. Yang
Jimmy C. Yang
NVNasim W. Vahidi
Nasim W. Vahidi
SLSang Heon Lee
Sang Heon Lee
SDShadi A. Dayeh
Shadi A. Dayeh

1 August 2011 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SLSeung Woo Lee
Seung Woo Lee
KMKyou Sik Min
Kyou Sik Min
JJJoonsoo Jeong
Joonsoo Jeong
JKJunghoon Kim
Junghoon Kim
SKSung June Kim
Sung June Kim
Flexible polymers have gained much attention in the development of low cost, magnetic resonance compatible, and nonfragile implantable medical devices. However, efficacy of the conventional polymer encapsulations containing hybrid interfaces is limited due to their relatively high moisture absorption and unstable interfacial adhesion in aqueous environments. As an alternative, we report on a monolithic encapsulation platform for neuroprosthetic devices using liquid crystal polymers (LCPs), which have a very low degree of moisture absorption (<;0.04%) and a fusion bondable interface. This platform offers monolithic encapsulation by fusion bonding of the hemispherical LCP package lids and LCP-based microelectrode arrays. The package lids were fabricated by thermoforming of the LCP films to provide the desired shape and size for encasing the electronic components and wireless telemetry coils. Fusion-bonded LCP encapsulations were evaluated using electrical leakage current measurements during in vitro soak tests. The measurements were done in both 37°C and 75°C phosphate-buffered saline (PBS) solution and showed that LCP encapsulation was superior and more reliable in PBS than polyimide and parylene-C encapsulations. In addition, LCP-based monolithic encapsulation provided reliable electrical insulation for more than 300 days in both 37°C and 75°C PBS solution.

11 August 2021 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
HLHoa Thanh Le
Hoa Thanh Le
RHRubaiyet I. Haque
Rubaiyet I. Haque
ZOZiwei Ouyang
Ziwei Ouyang
SLSeung Woo Lee
Seung Woo Lee
SFShelley I. Fried
Shelley I. Fried
AHAnpan Han
Anpan Han
MEMS inductors are used in a wide range of applications in micro- and nanotechnology, including RF MEMS, sensors, power electronics, and Bio-MEMS. Fabrication technologies set the boundary conditions for inductor design and their electrical and mechanical performance. This review provides a comprehensive overview of state-of-the-art MEMS technologies for inductor fabrication, presents recent advances in 3D additive fabrication technologies, and discusses the challenges and opportunities of MEMS inductors for two emerging applications, namely, integrated power electronics and neurotechnologies. Among the four top-down MEMS fabrication approaches, 3D surface micromachining and through-substrate-via (TSV) fabrication technology have been intensively studied to fabricate 3D inductors such as solenoid and toroid in-substrate TSV inductors. While 3D inductors are preferred for their high-quality factor, high power density, and low parasitic capacitance, in-substrate TSV inductors offer an additional unique advantage for 3D system integration and efficient thermal dissipation. These features make in-substrate TSV inductors promising to achieve the ultimate goal of monolithically integrated power converters. From another perspective, 3D bottom-up additive techniques such as ice lithography have great potential for fabricating inductors with geometries and specifications that are very challenging to achieve with established MEMS technologies. Finally, we discuss inspiring and emerging research opportunities for MEMS inductors.

27 November 2017 in Frontiers in Neuroscience
Verified
Journal Article
Open access
DFDaniel K. Freeman
Daniel K. Freeman
JOJonathan M. O'Brien
Jonathan M. O'Brien
PKParshant Kumar
Parshant Kumar
BDBrian Daniels
Brian Daniels
RIReed A. Irion
Reed A. Irion
SCStuart F. Cogan
Stuart F. Cogan
Wireless neural stimulators are being developed to address problems associated with traditional lead-based implants. However, designing wireless stimulators on the sub-millimeter scale (<1 mm3) is challenging. As device size shrinks, it becomes difficult to deliver sufficient wireless power to operate the device. Here, we present a sub-millimeter, inductively powered neural stimulator consisting only of a coil to receive power, a capacitor to tune the resonant frequency of the receiver, and a diode to rectify the radio-frequency signal to produce neural excitation. By replacing any complex receiver circuitry with a simple rectifier, we have reduced the required voltage levels that are needed to operate the device from 0.5 to 1 V (e.g., for CMOS) to ~0.25–0.5 V. This reduced voltage allows the use of smaller receive antennas for power, resulting in a device volume of 0.3–0.5 mm3. The device was encapsulated in epoxy, and successfully passed accelerated lifetime tests in 80°C saline for 2 weeks. We demonstrate a basic proof-of-concept using stimulation with tens of microamps of current delivered to the sciatic nerve in rat to produce a motor response.