Catarina Coelho

Ms. Catarina Coelho

Instituto de Investigação e Inovação em Saúde da Universidade do Porto, Porto, Portugal
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Catarina CoelhoCatarina Coelho
Catarina Coelho
LGLiliana Grenho
Liliana Grenho
Pedro GomesPedro Gomes
Pedro Gomes
PQPaulo Quadros
Paulo Quadros
MFMaria Helena V Fernandes
Maria Helena V Fernandes
Nano-hydroxyapatite has been used as an oral care ingredient, being incorporated in several products for the treatment of dental hypersensitivity and enamel remineralisation. Despite its promising results, regulatory and safety concerns have been discussed and questioned by the European Scientific Committee on Consumer Safety (SCCS) regarding the usage of hydroxyapatite nanoparticles in oral care products. In this work, a commercially available nano-hydroxyapatite was characterized and its cytocompatibility towards human gingival fibroblasts was evaluated, as well as its irritation potential using the in vitro HET-CAM assay. All the conditions chosen in this study tried to simulate the tooth brushing procedure and the hydroxyapatite nanoparticles levels normally incorporated in oral care products. The commercial hydroxyapatite nanoparticles used in this study exhibited a rod-like morphology and the expected chemical and phase composition. The set of in vitro cytotoxicity parameters accessed showed that these nanoparticles are highly cytocompatible towards human gingival fibroblasts. Additionally, these nanoparticles did not possess any irritation potential on HET-CAM assay. This study clarifies the issues raised by SCCS and it concludes that this specific nano-hydroxyapatite is cytocompatible, as these nanoparticles did not alter the normal behaviour of the cells. Therefore, they are safe to be used in oral care products.

28 April 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
RKRafaela-Maria Kavasi
Rafaela-Maria Kavasi
Catarina CoelhoCatarina Coelho
Catarina Coelho
Varvara PlataniaVarvara Platania
Varvara Platania
PQPaulo Quadros
Paulo Quadros
Maria ChatzinikolaidouMaria Chatzinikolaidou
Maria Chatzinikolaidou
Hydroxyapatite (HA) is an important component of the bone mineral phase. It has been used in several applications, such as bone regenerative medicine, tooth implants, drug delivery and oral care cosmetics. In the present study, three different batches of a commercial nanohydroxyapatite (nHA) material were physicochemically-characterized and biologically-evaluated by means of cytotoxicity and genotoxicity using appropriate cell lines based on well-established guidelines (ISO10993-5 and OECD 487). The nHAs were characterized for their size and morphology by dynamic light scattering (DLS) and transmission electron microscopy (TEM) and were found to have a rod-like shape with an average length of approximately 20 to 40 nm. The nanoparticles were cytocompatible according to ISO 10993-5, and the in vitro micronucleus assay showed no genotoxicity to cells. Internalization by MC3T3-E1 cells was observed by TEM images, with nHA identified only in the cytoplasm and extracellular space. This result also validates the genotoxicity since nHA was not observed in the nucleus. The internalization of nHA by the cells did not seem to affect normal cell behavior, since the results showed good biocompatibility of these nHA nanoparticles. Therefore, this work is a relevant contribution for the safety assessment of this nHA material.

1 April 2019 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
Catarina CoelhoCatarina Coelho
Catarina Coelho
RARita Araújo
Rita Araújo
PQPaulo Quadros
Paulo Quadros
Susana R SousaSusana R Sousa
Susana R Sousa
FMFernando J. Monteiro
Fernando J. Monteiro

5 November 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Catarina CoelhoCatarina Coelho
Catarina Coelho
TPTatiana Padrão
Tatiana Padrão
LCLaura Costa
Laura Costa
MPMarta T . Pinto
Marta T . Pinto
PCPaulo C. Costa
Paulo C. Costa
Susana R SousaSusana R Sousa
Susana R Sousa
Bone graft infections are serious complications in orthopaedics and the growing resistance to antibiotics is increasing the need for antibacterial strategies. The use of magnesium oxide (MgO) is an interesting alternative since it possesses broad-spectrum antibacterial activity. Additionally, magnesium ions also play a role in bone regeneration, which makes MgO more appealing than other metal oxides. Therefore, a bone substitute composed of hydroxyapatite and MgO (HAp/MgO) spherical granules was developed using different sintering heat-treatment cycles to optimize its features. Depending on the sintering temperature, HAp/MgO spherical granules exhibited distinct surface topographies, mechanical strength and degradation profiles, that influenced the in vitro antibacterial activity and cytocompatibility. A proper balance between antibacterial activity and cytocompatibility was achieved with HAp/MgO spherical granules sintered at 1100 ºC. The presence of MgO in these granules was able to significantly reduce bacterial proliferation and simultaneously provide a suitable environment for osteoblasts growth. The angiogenic and inflammation potentials were also assessed using the in vivo chicken embryo chorioallantoic membrane (CAM) model and the spherical granules containing MgO stimulated angiogenesis without increasing inflammation. The outcomes of this study evidence a dual effect of MgO for bone regenerative applications making this material a promising antibacterial bone substitute.

4 August 2020 in Materials
Verified
Journal Article
Open access
PDF file
SGSylwia Grabska
Sylwia Grabska
Alina SionkowskaAlina Sionkowska
Alina Sionkowska
Catarina CoelhoCatarina Coelho
Catarina Coelho
Fernando Jorge MonteiroFernando Jorge Monteiro
Fernando Jorge Monteiro
In this study, three-dimensional materials based on blends of silk fibroin (SF), collagen (Coll), and chitosan (CTS) cross-linked by glyoxal solution were prepared and the properties of the new materials were studied. The structure of the composites and the interactions between scaffold components were studied using FTIR spectroscopy. The microstructure was observed using a scanning electron microscope. The following properties of the materials were measured: density and porosity, moisture content, and swelling degree. Mechanical properties of the 3D materials under compression were studied. Additionally, the metabolic activity of MG-63 osteoblast-like cells on materials was examined. It was found that the materials were characterized by a high swelling degree (up to 3000% after 1 h of immersion) and good porosity (in the range of 80–90%), which can be suitable for tissue engineering applications. None of the materials showed cytotoxicity toward MG-63 cells.

11 September 2018 in Cosmetics
Verified
Journal Article
Open access
PDF file
JRJoana Maria Ramis
Joana Maria Ramis
Catarina CoelhoCatarina Coelho
Catarina Coelho
ACAlba Córdoba
Alba Córdoba
PQPaulo Quadros
Paulo Quadros
Marta MonjoMarta Monjo
Marta Monjo
Hydroxyapatite nanoparticles (HAP-NP) are incorporated in oral care products such as toothpastes and mouthwashes to treat dental sensitivity or to promote enamel remineralisation. Despite the good performance of HAP-NP in this application, it is important to ensure its safety for consumers. For that reason, the Scientific Committee on Consumer Safety (SCCS) evaluated the safety of HAP-NP as an oral care ingredient, but the issued opinion was not completely conclusive and the SCCS recommended that additional tests should be performed. Here, we used a commercially available human gingival epithelium (HGE) as a non-animal alternative and MTT cell viability, LDH activity, and IL-1alpha production were evaluated after 3.1% HAP-NP treatment for 10 min, 1 h, and 3 h. Moreover, the absorption of HAP-NP in the gingival tissue was assessed by transmission electron microscopy (TEM) analysis. Finally, the dissolution behaviour of HAP-NP in simulated gastric fluid was also investigated. No deleterious effect was observed for HGE tissues incubated with HAP-NP for all time-points and parameters evaluated. Moreover, a complete dissolution of 3.1% HAP-NP in simulated gastric fluid was observed after 7.5 min at 37 °C. In conclusion, our results evidence the safety of HAP-NP for oral care products with the use of an in vitro replacement alternative for human gingival epithelium and a simulated gastric fluid assay.