Wireless power transfer (WPT) technology has been widely applied to automobile industries, household electronics and medical devices because of its many advantages. The hybrid battery charging scheme, which combines constant voltage (CV) and constant current (CC), is considered to be quite reasonable in view of the limitations of the conventional CC/CV implementation scheme. In this study, based on the inductance and double capacitances-series (LCC-S) compensation topology, a switching hybrid topology is proposed for CC/CV electric vehicle (EV) battery charging. The topology parameters are designed according to the specified CV and zero phase angle (ZPA). In the CC charging mode, two additional capacitances are added to the topology for CC and ZPA implementation. Based on the proposed weak communication, the CC and CV charging mode can be converted via two AC switches (ACSs). The proposed hybrid system provides a simple structure, easy controllability, and stable output. A 2.5-kW experimental prototype is configured to verify the proposed hybrid charger. The maximum DC efficiencies (at 2.5-kW) of the CC and CV charging modes are 89.28% and 88.33%, respectively.
3 April 2020 in IEEE Transactions on Power Electronics
Compensation topologies play an essential role in wireless power transfer (WPT) systems for electric vehicles (EVs). Specifically, the double-sided ${LCC}$ compensated (DS- ${LCC}$ ) topology has been widely adopted, owing to its inherent advantages, such as load-independent constant current (CC) output, low sensitivity to load variation, and high freedom in parameter design. However, large resonant devices in the DS- ${LCC}$ topology lower the system efficiency and increase the complexity of optimal parameter tuning. Therefore, in this study, the parameters of the DS- ${LCC}$ compensation topology are reconfigured by adjusting the ratios of its two compensation inductances without changing the specified system-level parameters, such as the loosely coupled transformer (LCT), operating frequency, and specified CC outputs. The system performance under each case is analyzed and compared in detail, based on which, an asymmetric parameter-design method is proposed to optimize the system efficiency. To verify the reasonability of the proposed tuning method, a 6.6-kW experimental prototype is configured, and comparative experiments are conducted. The experimental results indicate that, compared with the conventional method, the proposed parameter-tuning method improves the system efficiency under overall load conditions, especially under light loads.
20 October 2020 in IEEE Transactions on Power Electronics
The use of wireless power transfer technology in unmanned aerial vehicle (UAV) systems is rapidly improving in different application areas. The main limitations of electric-powered UAVs are their charging range and stability in dynamic conditions. To solve these, this paper proposes a hybrid control method based on DC-link and switched capacitor control with a fixed operating frequency. The DC-link voltage is regulated by the boost PFC converter to smoothen the output voltage, and the switched capacitor is used to dynamically compensate for self-inductance variations under dynamic coupling conditions. The output voltage stabilization and near-unity power factor of the input impedance can be achieved by applying the hybrid control method. Therefore, efficiency improvement can be achieved. Furthermore, the proposed control method can also be applied to systems with large coupling variations. To verify the proposed control method, a 500-W prototype was set up in the laboratory, and the experimental results proved that the control method could ensure a stable output voltage with horizontal and vertical offsets of 200 mm and 62 mm respectively. Additionally, the results show that the maximum efficiency of the proposed control method is 91.9%, demonstrating that the proposed method effectively improves the efficiency.
13 December 2021 in IEEE Transactions on Transportation Electrification
To simplify the tuning process and enhance the parameter robustness of the model predictive control (MPC) for grid-connected inverters, an improved phase-locked loop (PLL) and a new inductance online identification method are proposed in this article. First, an improved finite control set-based PLL is presented, which removes the PI controller, simplifying the tuning process. Next, a new inductance online identification method based on a model reference adaptive system is presented, which takes the actual grid voltage and the estimated one as the reference model and adjustable model, respectively. Here, a sliding mode observer (SMO) is proposed to estimate the grid voltage, and the inductance adaptive law is deduced by exploring the effects of the inductance on the estimated grid voltage. Furthermore, the sensitivity of the proposed SMO to frequency deviation is also analyzed, which shows that a proper sliding mode gain can be selected to reduce the effects of frequency deviation. Thus, a fixed grid frequency of 50 Hz can be used in the proposed SMO, indicating that it is not required to calculate the actual grid frequency using differential operation any more. Finally, experimental studies verify the validity of the proposed strategies.
1 June 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
In wireless power transfer system, not only the mutual inductance variation but also the self-inductance variation can be occurred under the misalignment condition. In light of the Unmanned Aerial Vehicles, the variation of the secondary self-inductance and mutual inductance are significantly under the misalignment condition. In order to stabilize the output voltage and current and achieve near-ZPA (near-zero phase angle) of the input impedance. A variable inductor control is presented in this paper, which regulate the inductance of the secondary side by adjusting the dc bias current under large k variation. The proposed control method does not need any auxiliary circuit, and constant current-constant voltage (CC-CV) charging can be achieved by controlling the duty cycle of the boost converter. To verify the proposed control method, a 500-W prototype was set up in the laboratory, and the variable inductor control method ensures a stable output voltage and current with horizontal and vertical offsets of 200 mm and 92 mm, respectively. Additionally, communication is not need between primary and secondary side, and the results show that the maximum efficiency is 92.9%, which is 2.3% higher than the conventional dc-dc regulation method.
In inductive power transfer (IPT) systems, series–series (S-S) and double capacitances and inductances–series (LCCL-S) compensation topologies are widely utilized. In this study, the basic characteristics of S-S and LCCL-S are analyzed and compared in the tuning state. In addition, considering the universality of detuning, and because the two topologies have the same secondary structures, the voltage and current stress on components, input impedances, voltage gains, and output powers of S-S and LCCL-S are mainly analyzed and compared in the detuning state, which is caused by variations in the secondary compensation capacitance. To compare the efficiency of the two topologies and verify the comparative analysis, comparative experiments based on a 2.4-kW IPT experimental prototype are conducted. The comparative result shows that the S-S compensation topology is more sensitive to load variations and less sensitive to secondary compensation capacitance variations than LCCL-S. Both in the tuning and detuning states, the efficiency of the S-S topology is higher in high-power electric vehicle (EV) applications, and the efficiency of LCCL-S is higher in low-power.