Xinglin Yu

Dr. Xinglin Yu


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
XYXiang Yu
Xiang Yu
XCXiangdong Chen
Xiangdong Chen
XYXinglin Yu
Xinglin Yu
XCXinpeng Chen
Xinpeng Chen
XDXing Ding
Xing Ding
KTKung Tang
Kung Tang
In this article, a Nafion/MoS 2 hybrid thin film was deposited on quartz crystal microbalance (QCM) for detecting humidity, in which moderate MoS 2 nanosheets with small size were dispersed into a Nafion membrane to improve its humidity sensitivity. The experimental results indicate that a hybrid film QCM humidity sensor with the best volume ratio of Nafion/MoS 2 exhibits a considerably higher shift frequency (−11 879 Hz) than a pure Nafion film QCM humidity sensor, even more than most of the reported QCM humidity sensors. It could be that the molybdenum disulfide nanosheets dispersed in the Nafion film would form some nano-assembly near the hydrophilic group of Nafion, which greatly enhances the ability of the composite film to establish water channels, thus promoting hydrophilicity of the composite film. The highly sensitive humidity sensor could clearly distinguish tiny humidity difference near the back and palm of a hand. Therefore, it has potential application in human–robot collaboration.

26 March 2018 in IEEE Transactions on Nanotechnology
Verified
Journal Article
Closed access
XYXinglin Yu
Xinglin Yu
XCXiangdong Chen
Xiangdong Chen
HLHui Li
Hui Li
XDXing Ding
Xing Ding
In this paper, a high-stability QCM humidity sensor coated with nanodiamond (ND)/multiwalled carbon nanotubes (MWCNTs) nanocomposite film was purposed based on good dispersion of MWCNTs in ND solution. The experimental results demonstrated that the sensor not only had a relative high frequency shift with humidity change, but also maintained a high quality (Q) factor compared with that of pure ND film coated sensor. In high humidity, the Q factor of ND/MWCNTs coated sensor is about four times larger than that of pure ND coated sensor, and can retain negligible change as long as several months. The possible reason was analyzed and discussed. Moreover, the sensor exhibited low hysteresis, fast response/recovery time and good repeatability.

18 August 2021 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
XYXinglin Yu
Xinglin Yu
XCXiangdong Chen
Xiangdong Chen
XYXiang Yu
Xiang Yu
XCXinpeng Chen
Xinpeng Chen
XDXing Ding
Xing Ding
In this work, we, for the first time, propose a quartz crystal microbalance (QCM) humidity sensor that is prepared by a one-step method based on pencil drawing. The scanning electron microscopy (SEM), atomic force microscope (AFM), and Raman spectra confirm some graphite flakes, and a layer of sensing film is formed, demonstrating the successful preparation of the QCM sensor. A series of experiments were performed by means of oscillating circuit and impedance analysis at room temperature. The impedance analysis method demonstrates that the QCM humidity sensor exhibits an excellent stability with a quality factor ( ${Q}$ ) that only drops from 47 923 to 43 849 in the whole humidity range, which is better than ever reported QCM humidity sensors. In addition, the sensor shows a good long-term stability with a maximal frequency deviation of less than 5% in a long-term test. Furthermore, the sensor displays a rapid response time ~8s and a recovery time less than 5 s. The underlying reasons for these excellent properties of the proposed sensor are analyzed and discussed. This research demonstrates that the pencil-drawn method is a simple, green, and cost-effective way for constructing a QCM humidity sensor with high performance.

22 February 2019 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
XYXinglin Yu
Xinglin Yu
XCXiangdong Chen
Xiangdong Chen
XYXiang Yu
Xiang Yu
XCXinpeng Chen
Xinpeng Chen
XDXing Ding
Xing Ding
XZXuan Zhao
Xuan Zhao

25 January 2025 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
XYXinglin Yu
Xinglin Yu
SMSihan Ma
Sihan Ma
DLDeng Long
Deng Long
WLWentao Li
Wentao Li
XYXiang Yu
Xiang Yu
XDXing Ding
Xing Ding

6 December 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XCXinpeng Chen
Xinpeng Chen
XCXiangdong Chen
Xiangdong Chen
XDXing Ding
Xing Ding
XYXiang Yu
Xiang Yu
XYXinglin Yu
Xinglin Yu
This work reports a manufacturing method of NH3 gas sensor based on reduced graphene oxide/hydroxylated multi-walled carbon nanotu-bes/polyaniline (rGO/HMWCNTs/PANI) ternary composites. Firstly, rGO/HM-WCNT composites are fabricated from GO/HMWCNTs suspension via hydrot-hermal reduction method. Secondly, the rGO/HMWCNTs composites and aniline monomers are used to synthesize rGO/HMWCNTs/PANI ternary composites by in-situ chemical oxidative polymerization. The results indicate that the rGO/HMWCNTs/PANI ternary composites have significantly higher sensitive properties to NH3 gas compare to pure PANI and HMWCNTs/PANI binary composites. Its response to NH3 gas is respectively about 4.8 times that of pure PANI and 2.2 times that of HMWCNTs/PANI binary composites over the concentration range of 10-1000 ppm. The main reason may be that this method not only improves dispersion of HMWCNTs in PANI due to introduction of GO, but also maintains good charge transfer between HMWCNTs and PANI owing to hydrothermal reduction of GO to rGO, thus enhancing NH3 gas-sensitive properties of the ternary composites.