In this article, a Nafion/MoS 2 hybrid thin film was deposited on quartz crystal microbalance (QCM) for detecting humidity, in which moderate MoS 2 nanosheets with small size were dispersed into a Nafion membrane to improve its humidity sensitivity. The experimental results indicate that a hybrid film QCM humidity sensor with the best volume ratio of Nafion/MoS 2 exhibits a considerably higher shift frequency (−11 879 Hz) than a pure Nafion film QCM humidity sensor, even more than most of the reported QCM humidity sensors. It could be that the molybdenum disulfide nanosheets dispersed in the Nafion film would form some nano-assembly near the hydrophilic group of Nafion, which greatly enhances the ability of the composite film to establish water channels, thus promoting hydrophilicity of the composite film. The highly sensitive humidity sensor could clearly distinguish tiny humidity difference near the back and palm of a hand. Therefore, it has potential application in human–robot collaboration.
In this letter, a MoS 2 -based humidity sensor braced by SiO 2 microsphere layers with rapid response was developed. The results demonstrated that the humidity sensor can exhibit a subsecond response. A mechanism based on the morphology and structure of the sensing film was proposed to explain the rapid response behavior of humidity sensors. In addition, the effect of film thickness on response time was discussed. This letter demonstrated that the MoS 2 -based humidity sensor braced by SiO 2 microspheres is suitable for the miniature drip infusion rate detection device.
Fullerenes (C60) exhibits many advantageous properties but its poor solubility seriously restricts its applications. In this paper, C60 is dissolved in graphene oxide (GO) aqueous solution homogenously. This water-soluble composite material of GO/C60 is used for making a capacitive humidity sensor. This sensor shows a sensitivity of three times larger than that of the sensor based on C60 film. The possible reason is that C60 is uniformly adsorbed on the surface of GO, thus reducing the agglomeration of C60. This is supported by TEM, FTIR, and complex impedance test.
In this work, we, for the first time, propose a quartz crystal microbalance (QCM) humidity sensor that is prepared by a one-step method based on pencil drawing. The scanning electron microscopy (SEM), atomic force microscope (AFM), and Raman spectra confirm some graphite flakes, and a layer of sensing film is formed, demonstrating the successful preparation of the QCM sensor. A series of experiments were performed by means of oscillating circuit and impedance analysis at room temperature. The impedance analysis method demonstrates that the QCM humidity sensor exhibits an excellent stability with a quality factor ( ${Q}$ ) that only drops from 47 923 to 43 849 in the whole humidity range, which is better than ever reported QCM humidity sensors. In addition, the sensor shows a good long-term stability with a maximal frequency deviation of less than 5% in a long-term test. Furthermore, the sensor displays a rapid response time ~8s and a recovery time less than 5 s. The underlying reasons for these excellent properties of the proposed sensor are analyzed and discussed. This research demonstrates that the pencil-drawn method is a simple, green, and cost-effective way for constructing a QCM humidity sensor with high performance.
22 February 2019 in IEEE Transactions on Electron Devices