Mohd Syahmi Jamaludin

Dr. Mohd Syahmi Jamaludin

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2019 in Bioengineering
Verified
Journal Article
Open access
PDF file
MJMohd Syahmi Jamaludin
Mohd Syahmi Jamaludin
AHAkihiko Hanafusa
Akihiko Hanafusa
SYShinichiro Yamamoto
Shinichiro Yamamoto
YAYukio Agarie
Yukio Agarie
HOHiroshi Otsuka
Hiroshi Otsuka
KOKengo Ohnishi
Kengo Ohnishi
In this study, we estimated and validated the pressure distribution profile between the residuum and two types of prosthetic sockets for transfemoral amputees by utilizing a finite element analysis. Correct shaping of the socket for an appropriate load distribution is a critical process in the design of lower-limb prosthesis sockets. The pressure distribution profile provides an understanding of the relationship between the socket design and the level of subject comfortability. Estimating the pressure profile is important, as it helps improve the prosthesis through an evaluation of the socket design before it undergoes the fabrication process. This study focused on utilizing a magnetic resonance imaging (MRI)-based three-dimensional (3D) model inside a predetermined finite element simulation. The simulation was predetermined by mimicking the actual socket-fitting environment. The results showed that the potential MRI-based 3D model simulation could be used as an estimation tool for a pressure distribution profile due to the high correlation coefficient value (R2 > 0.8) calculated when the pressure profiles were compared to the experiment data. The simulation also showed that the pressure distribution in the proximal area was higher (~30%) than in the distal area of the prosthetic socket for every subject. The results of this study will be of tremendous interest for fabricators through the use of a finite element model as an alternative method for the prefabrication and evaluation of prosthetic sockets. In future prosthetic socket fabrications, less intervention will be required in the development of a socket, and the participation of the subject in the socket-fitting session will not be necessary. The results suggest that this study will contribute to expanding the development of an overall prefabrication evaluation system to allow healthcare providers and engineers to simulate the fit and comfort of transfemoral prosthetics.

31 August 2021 in Journal of Sustainability Science and Management
Verified
Journal Article
Closed access
MJMohd Syahmi Jamaludin
Mohd Syahmi Jamaludin
UMUniversiti Putra Malaysia
Universiti Putra Malaysia
EJErnie Syazween Junaidi
Ernie Syazween Junaidi
Juliana JalaludinJuliana Jalaludin
Juliana Jalaludin
ATAbdul Rohim Tualeka
Abdul Rohim Tualeka
AUAirlangga University
Airlangga University

1 January 2017 in Asian Journal of Chemistry
Verified
Journal Article
Open access
SSSyed Salman Shafqat
Syed Salman Shafqat
Amir KhanAmir Khan
Amir Khan
MKMisbahul Ain Khan
Misbahul Ain Khan
SSShanti Faridah Salleh
Shanti Faridah Salleh
MJMohd Syahmi Jamaludin
Mohd Syahmi Jamaludin
PCPang Suh Cem
Pang Suh Cem


4 September 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MJMohd Syahmi Jamaludin
Mohd Syahmi Jamaludin
AHAkihiko Hanafusa
Akihiko Hanafusa
YSYamamoto Shinichirou
Yamamoto Shinichirou
YAYukio Agarie
Yukio Agarie
HOHiroshi Otsuka
Hiroshi Otsuka
KOKengo Ohnishi
Kengo Ohnishi
Recent technologies have suggested the utilization of three-dimensional (3D) printing technology to enhance the fabrication accuracy of prosthetics. Accordingly, simulations are used to obtain precise parameters for subject-specified prosthetic socket. This study proposes an evaluation system to measure the accuracy of a subject-specific 3D transfemoral residuum model during the interaction with the socket in conjunction with the application of finite element methods. The proposed system can be used in future validations of socket fabrication. The evaluation is based on the measurement of the residuum’s soft tissue deformation inside two types of prosthetic sockets. In comparison with other studies, the 3D models were constructed with magnetic resonance images (MRI) with the aid of computer-aided design (CAD) software. The measurement of soft tissue deformation was conducted based on the measurement of the volumetric value of fat, muscle and skin in the pre- and post-donning phases. The result yielded a promising correlation coefficient value between the simulation and the experiment in the soft tissue deformation evaluation. The relation of the muscle–fat ratio in the residuum is extremely important in the determination of the ability of the prosthetic to deform. The environment during the socket fitting session was similar to that defined by the set boundary conditions in simulations. In view of the promising results of this study, the evaluation system proposed herein is considered reliable and is envisaged to be used in future research.

12 December 2016 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
MHMohamad Syamim Hamsawi
Mohamad Syamim Hamsawi
AAAna Sakura Zainal Abidin
Ana Sakura Zainal Abidin
SMShahrol Mohamaddan
Shahrol Mohamaddan
RMRasli Muslimen
Rasli Muslimen
MJMohd Syahmi Jamaludin
Mohd Syahmi Jamaludin
NJNazreen Junaidi
Nazreen Junaidi
MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry