In this study, we estimated and validated the pressure distribution profile between the residuum and two types of prosthetic sockets for transfemoral amputees by utilizing a finite element analysis. Correct shaping of the socket for an appropriate load distribution is a critical process in the design of lower-limb prosthesis sockets. The pressure distribution profile provides an understanding of the relationship between the socket design and the level of subject comfortability. Estimating the pressure profile is important, as it helps improve the prosthesis through an evaluation of the socket design before it undergoes the fabrication process. This study focused on utilizing a magnetic resonance imaging (MRI)-based three-dimensional (3D) model inside a predetermined finite element simulation. The simulation was predetermined by mimicking the actual socket-fitting environment. The results showed that the potential MRI-based 3D model simulation could be used as an estimation tool for a pressure distribution profile due to the high correlation coefficient value (R2 > 0.8) calculated when the pressure profiles were compared to the experiment data. The simulation also showed that the pressure distribution in the proximal area was higher (~30%) than in the distal area of the prosthetic socket for every subject. The results of this study will be of tremendous interest for fabricators through the use of a finite element model as an alternative method for the prefabrication and evaluation of prosthetic sockets. In future prosthetic socket fabrications, less intervention will be required in the development of a socket, and the participation of the subject in the socket-fitting session will not be necessary. The results suggest that this study will contribute to expanding the development of an overall prefabrication evaluation system to allow healthcare providers and engineers to simulate the fit and comfort of transfemoral prosthetics.
Accurate evaluation of pressure distribution at the socket–limb interface is essential for improving prosthetic fit and comfort in transfemoral amputees. This study aimed to develop a data-driven framework that integrates machine learning–based segmentation with finite element method (FEM) to quantitatively assess interface pressure during socket application. MRI data from a transfemoral amputee were processed using a custom image segmentation algorithm to extract adipose tissue, femur, and ischium, achieving high F-measure scores. The segmented tissues were reconstructed into 3D models, refined through outlier removal and surface smoothing, and used for FEM simulations in LS-DYNA. Pressure values were extracted at nine sensor locations and compared with experimental measurements. The results showed consistent polarity between measured and simulated values across all points. Furthermore, at the eight locations excluding the ischial tuberosity (IS) region, a statistically significant and moderately strong positive correlation was observed between measured and simulated pressures (r = 0.7485, p < 0.05). Notably, positive pressure regions demonstrated close agreement between experimental and simulated values, whereas the discrepancy observed at the IS region was likely influenced by the medial boundary conditions introduced to prevent unrealistic tissue displacement. This difference highlights a limitation of the current simulation setup. Overall, the proposed framework demonstrated reliable pressure estimation and offers a promising approach for personalized prosthetic socket design through automated anatomical modeling and simulation.
Background: Accurate evaluation of pressure distribution at the socket–limb interface is essential for improving prosthetic fit and comfort in transfemoral amputees. This study aimed to develop a proof-of-concept framework that integrates machine learning–based segmentation with the finite element method (FEM) to explore the feasibility of an initial workflow for residual-limb analysis during socket application. Methods: MRI data from a transfemoral amputee were processed using a custom image segmentation algorithm to extract adipose tissue, femur, and ischium, achieving high F-measure scores. The segmented tissues were reconstructed into 3D models, refined through outlier removal and surface smoothing, and used for FEM simulations in LS-DYNA. Pressure values were extracted at nine sensor locations and compared with experimental measurements to provide a preliminary qualitative assessment of model behaviour. Results: The results showed consistent polarity between measured and simulated values across all points. Moderate correspondence was observed at eight low-pressure locations, whereas a substantial discrepancy occurred at the ischial tuberosity (IS), the primary load-bearing site. This discrepancy likely reflects the combined influence of geometric deviation in the reconstructed ischium and the non-physiological medial boundary condition required to prevent unrealistic tissue displacement. This limitation indicates that the current formulation does not support reliable quantitative interpretation at clinically critical locations. Conclusions: Overall, the proposed framework provides an initial demonstration of the methodological feasibility of combining automated anatomical modeling with FEM for exploratory pressure evaluation, indicating that such an integrated pipeline may serve as a useful foundation for future development. While extensive refinement and validation are required before any quantitative or clinically meaningful application is possible, this work represents an early step toward more advanced computational investigations of transfemoral socket–limb interaction.