Xiangdi Meng

Ms. Xiangdi Meng

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
XMXiangdi Meng
Xiangdi Meng
SLShuyu Lin
Shuyu Lin
To increase the ultrasonic intensity and power of a piezoelectric transducer, a cascaded piezoelectric ultrasonic transducer with the three sets of piezoelectric ceramic stacks is analyzed. The cascaded piezoelectric ultrasonic transducer consists of four metal cylinders and three sets of piezoelectric ceramic stacks in the longitudinal direction. In analysis, the electromechanical equivalent circuit of the cascaded piezoelectric ultrasonic transducer is obtained, as well as the resonance/anti-resonance frequencies equations. By means of an analytical method, when the position of piezoelectric ceramic stacks PZT-2/PZT-3 changes, the resonance/anti-resonance frequencies and the effective electromechanical coupling coefficient of the cascaded piezoelectric ultrasonic transducer have certain characteristics. Several prototypes of the cascaded piezoelectric ultrasonic transducer are manufactured. The experimentally measured resonance frequencies are in good agreement with the theoretical and simulated results. The cascaded piezoelectric ultrasonic transducer with three sets of piezoelectric ceramic stacks presented in this paper is expected to be used in the field of high power ultrasound.

29 September 2023 in Ultrasonics
Verified
Journal Article
Closed access
XMXiangdi Meng
Xiangdi Meng
MDMingxi Deng
Mingxi Deng
WLWeibin Li
Weibin Li

29 September 2025 in Applied Physics Letters
Verified
Journal Article
Closed access
XMXiangdi Meng
Xiangdi Meng
CXCaibin Xu
Caibin Xu
WLWeibin Li
Weibin Li
SGShuai Guo
Shuai Guo
JWJiaxiang Wang
Jiaxiang Wang
MDMingxi Deng
Mingxi Deng
This Letter proposes an ultrasonic stress monitoring method utilizing the S1 zero group velocity (S1-ZGV) mode based on a PVDF comb transducer. Experimental investigations have revealed that under varying uniaxial stress conditions, both the measured S1-ZGV frequency and its corresponding amplitude exhibit appreciable variations. By adopting the relative change rate of the amplitude corresponding to the S1-ZGV frequency (denoted by RCA) as the characteristic parameter, it is evident that RCA demonstrates a monotonic and highly sensitive response to the applied uniaxial stress. Notably, RCA exhibits a significant increase as the applied uniaxial stress rises. This characteristic enables the use of RCA to predict the stress state, facilitating real-time stress monitoring. Experimental validation indicates that the predicted stress values align closely with the actual applied stress values, demonstrating a high level of accuracy in stress prediction. This method enables real-time and in situ monitoring of the stress state in thin plates subjected to uniaxial stresses, which holds paramount importance for a wide array of industrial applications in structural health monitoring.

12 August 2025 in NDT & E International
Verified
Journal Article
Closed access
XMXiangdi Meng
Xiangdi Meng
WLWeibin Li
Weibin Li
SGShuai Guo
Shuai Guo
MDMingxi Deng
Mingxi Deng

6 May 2026 in NDT & E International
Verified
Journal Article
Closed access
NZNan Zhang
Nan Zhang
CXCaibin Xu
Caibin Xu
XMXiangdi Meng
Xiangdi Meng
MDMingxi Deng
Mingxi Deng