Patrick Fuchs

Dr. Patrick Fuchs

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2020 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
BVBart de Vos
Bart de Vos
PFPatrick Fuchs
Patrick Fuchs
TOThomas O'REilly
Thomas O'REilly
AWandrew webb
andrew webb
RRRobert Remis
Robert Remis
In this paper we design and construct gradient coils for a Halbach permanent magnet array magnetic resonance (MR) scanner. The target field method, which is widely applied for the case of axial static magnetic fields, has been developed for a transverse static magnetic field as produced by a Halbach permanent magnet array. Using this method, current densities for three gradient directions are obtained and subsequently verified using a commercial magneto-static solver. Stream functions are used to turn the surface current densities into wire patterns for constructing the gradient coils. The measured fields are in good agreement with simulations and their prescribed target fields. Three dimensional images have been acquired using the constructed gradient coils with very low degree of geometric distortion.

5 April 2025 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Open access
PDF file
PFPatrick Fuchs
Patrick Fuchs
OKOliver C. Kiersnowski
Oliver C. Kiersnowski
CMCarlos Milovic
Carlos Milovic
KSKarin Shmueli
Karin Shmueli
In quantitative susceptibility mapping (QSM), it is impossible to define an absolute reference for the reconstructed susceptibility values. Therefore, it has been suggested to use a relative reference, such as the mean susceptibility within an anatomical ROI. We investigated the theoretical basis of referencing, and what impact it may have on statistical ROI comparisons, particularly for clinical applications. We analysed a clinical epilepsy study and in-silico QSM reconstruction challenge data with various reference regions. The results are analysed as in a clinical study and resulting statistical variations are investigated from a theoretical point of view. We found that referencing has an impact on the significance of clinical findings. These effects may arise from a change in the precision of test statistics due to referencing. We also show potential biasing of results from referencing. Our findings suggest there may not be one “optimal” reference region, and care should always be taken with reference region selection depending on the specific pathology or cohort under investigation. Not explicitly referencing is less likely to lead to false positives than cherry picking a reference region to maximize statistically significant results. We encourage results to be published with their reference to facilitate future comparisons of datasets from different sources.

1 February 2019 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
RLReijer Leijsen
Reijer Leijsen
PFPatrick Fuchs
Patrick Fuchs
WBWyger Brink
Wyger Brink
AWandrew webb
andrew webb
RRRob F Remis
Rob F Remis
The main objective of electrical-property tomography (EPT) is to retrieve dielectric tissue parameters from B ^ 1 + data as measured by a magnetic-resonance (MR) scanner. This is a so-called hybrid inverse problem in which data are defined inside the reconstruction domain of interest. In this paper, we discuss recent and new developments in EPT based on the contrast-source inversion (CSI) method. After a short review of the basics of this method, two- and three-dimensional implementations of CSI–EPT are presented along with a very efficient variant of 2D CSI–EPT called first-order induced current EPT (foIC-EPT). Practical implementation issues that arise when applying the method to measured data are addressed as well, and the limitations of a two-dimensional approach are extensively discussed. Tissue-parameter reconstructions of an anatomically correct male head model illustrate the performance of two- and three-dimensional CSI–EPT. We show that 2D implementation only produces reliable reconstructions under very special circumstances, while accurate reconstructions can be obtained with 3D CSI–EPT.

1 October 2018 in IEEE Transactions on Computational Imaging
Verified
Journal Article
Closed access
PFPatrick Fuchs
Patrick Fuchs
SMStefano Mandija
Stefano Mandija
PSPeter R. S. Stijnman
Peter R. S. Stijnman
WBWyger Brink
Wyger Brink
Cássio van den BergCássio van den Berg
Cássio van den Berg
RRRob F Remis
Rob F Remis
In this paper, we present an efficient dedicated electrical properties tomography algorithm (called first-order current density EPT) that exploits the particular radio frequency field structure, which is present in the midplane of a birdcage coil, to reconstruct conductivity and permittivity maps in this plane from B1+ data. The algorithm consists of a current density and an electrical properties step. In the current density reconstruction step, the induced currents in the midplane are determined by acting with a specific first-order differentiation operatoron the B1+ data. In the electrical properties step, we first determine the electric field strength by solving a particular integral equation, and subsequently determine conductivity and permittivity maps from the constitutive relations. The performance of the algorithm is illustrated by presenting reconstructions of a human brain model based on simulated (noise corrupted) data and of a known phantom model based on experimental data. The method manages to reconstruct conductivity profiles without model related boundary artefacts and is also more robust to noise because only first-order differencing of the data is required as opposed to second-order data differencing in Helmholtz-based approaches. Moreover, reconstructions can be performed in less than a second, allowing for essentially real-time electrical properties mapping.

20 August 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
OKOliver C. Kiersnowski
Oliver C. Kiersnowski
PFPatrick Fuchs
Patrick Fuchs
SWStephen J. Wastling
Stephen J. Wastling
JNJannette Nassar
Jannette Nassar
JTJohn S. Thornton
John S. Thornton
KSKarin Shmueli
Karin Shmueli
Purpose: Data for QSM are typically acquired using multi‐echo 3D gradient echo (GRE), but EPI can be used to accelerate QSM and provide shorter acquisition times. So far, EPI‐QSM has been limited to single‐echo acquisitions, which, for 3D GRE, are known to be less accurate than multi‐echo sequences. Therefore, we compared single‐echo and multi‐echo EPI‐QSM reconstructions across a range of parallel imaging and multiband acceleration factors.Methods: Using 2D single‐shot EPI in the brain, we compared QSM from single‐echo and multi‐echo acquisitions across combined parallel‐imaging and multiband acceleration factors ranging from 2 to 16, with volume pulse TRs from 21.7 to 3.2 s, respectively. For single‐echo versus multi‐echo reconstructions, we investigated the effect of acceleration factors on regional susceptibility values, temporal noise, and image quality. We introduce a novel masking method based on thresholding the magnitude of the local field gradients to improve brain masking in challenging regions.Results: At 1.6‐mm isotropic resolution, high‐quality QSM was achieved using multi‐echo 2D EPI with a combined acceleration factor of 16 and a TR of 3.2 s, which enables functional applications. With these high acceleration factors, single‐echo reconstructions are inaccurate and artefacted, rendering them unusable. Multi‐echo acquisitions greatly improve QSM quality, particularly at higher acceleration factors, provide more consistent regional susceptibility values across acceleration factors, and decrease temporal noise compared with single‐echo QSM reconstructions.Conclusion: Multi‐echo acquisition is more robust for EPI‐QSM across parallel imaging and multiband acceleration factors than single‐echo acquisition. Multi‐echo EPI can be used for highly accelerated acquisition while preserving QSM accuracy and quality relative to gold‐standard 3D‐GRE QSM.

1 October 2025 in NeuroImage
Verified
Journal Article
Open access
CMCarlos Milovic
Carlos Milovic
PFPatrick Fuchs
Patrick Fuchs
MLMathias Lambert
Mathias Lambert
OAOriana Arsenov
Oriana Arsenov
OKOliver C. Kiersnowski
Oliver C. Kiersnowski
KSKarin Shmueli
Karin Shmueli
Background field removal (BFR) is an important step in the QSM pipeline, enabling the reconstruction of local susceptibility distributions by removing contributions from sources outside the region of interest (ROI). BFR requires calculation of a binary ROI mask, to which most BFR methods are sensitive. We investigated how masking, and errors in local field map estimation, impact the quality of QSM reconstructions. We used the 2019 QSM Reconstruction Challenge brain phantom to simulate multi-echo gradient echo acquisitions. Echoes were combined using complex fitting followed by unwrapping with SEGUE. Fifteen background field removal methods were applied using 4 local field masks. Local fields were compared with RMSE. Seven different QSM reconstruction algorithms were applied to the local fields and evaluated using the 2019 QSM Challenge metrics. For local field map estimation, PDF and MSMV performed best overall, although their performance was sensitive to the mask. V-SHARP and RESHARP were more robust to masking and showed good performance. LBV had low accuracy, which was improved by removing a polynomial fit. Surprisingly, this did not propagate to susceptibility, where LBV without polynomial fitting performed better. When paired with the Weak Harmonic QSM algorithm, LBV showed the best overall performance with low sensitivity to the mask; PDF and MSMV were next best. PDF and MSMV are robust choices for estimating local field maps and provide accurate QSM but can lead to susceptibility underestimation near brain boundaries. LBV is less reliable for local field map estimation but gives accurate results when used with weak harmonic QSM.