Alberto Rico-Yuste

Dr. Alberto Rico-Yuste

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2019 in Polymers
Verified
Journal Article
Open access
PDF file
ARAlberto Rico-Yuste
Alberto Rico-Yuste
Sergio CarrascoSergio Carrasco
Sergio Carrasco
We report on the development of new optical sensors using molecularly imprinted polymers (MIPs) combined with different materials and explore the novel strategies followed in order to overcome some of the limitations found during the last decade in terms of performance. This review pretends to offer a general overview, mainly focused on the last 3 years, on how the new fabrication procedures enable the synthesis of hybrid materials enhancing not only the recognition ability of the polymer but the optical signal. Introduction describes MIPs as biomimetic recognition elements, their properties and applications, emphasizing on each step of the fabrication/recognition procedure. The state of the art is presented and the change in the publication trend between electrochemical and optical sensor devices is thoroughly discussed according to the new fabrication and micro/nano-structuring techniques paving the way for a new generation of MIP-based optical sensors. We want to offer the reader a different perspective based on the materials science in contrast to other overviews. Different substrates for anchoring MIPs are considered and distributed in different sections according to the dimensionality and the nature of the composite, highlighting the synergetic effect obtained as a result of merging both materials to achieve the final goal.

22 March 2016 in Analytical Chemistry
Verified
Journal Article
Closed access
ARAlberto Rico-Yuste
Alberto Rico-Yuste
VGVictoria González-Vallejo
Victoria González-Vallejo
Elena Benito PeñaElena Benito Peña
Elena Benito Peña
TETomás de Las Casas Engel
Tomás de Las Casas Engel
Guillermo OrellanaGuillermo Orellana
Guillermo Orellana
Maria C Moreno-BondiMaria C Moreno-Bondi
Maria C Moreno-Bondi

1 January 2016 in Food Chemistry
Verified
Journal Article
Closed access
Elena Benito PeñaElena Benito Peña
Elena Benito Peña
VGVictoria González-Vallejo
Victoria González-Vallejo
ARAlberto Rico-Yuste
Alberto Rico-Yuste
LBLetricia Barbosa-Pereira
Letricia Barbosa-Pereira
JCJose M. Cruz
Jose M. Cruz
Maria C Moreno-BondiMaria C Moreno-Bondi
Maria C Moreno-Bondi


20 September 2018 in Food Additives & Contaminants: Part A
Verified
Journal Article
Closed access
ARAlberto Rico-Yuste
Alberto Rico-Yuste
LGLidia N. Gómez-Arribas
Lidia N. Gómez-Arribas
MPMaría Concepción Pérez-Conde
María Concepción Pérez-Conde
JUJavier Urraca
Javier Urraca
Maria C Moreno-BondiMaria C Moreno-Bondi
Maria C Moreno-Bondi
A sensitive and reliable method using pressurised liquid extraction (PLE) followed by molecularly imprinted solid phase extraction (MISPE) and high performance liquid chromatography with fluorescence detection (HPLC–FLD) has been developed for the analysis of alternariol (AOH) and alternariol monomethyl ether (AME) in tomato samples. Influence of several extraction parameters that affect PLE efficiency were evaluated for the simultaneous extraction of both mycotoxins in the selected samples. AOH and AME were optimally extracted using MeOH/water (25:75, v/v) at 70°C as solvent, a pressure of 1000 psi and a single extraction cycle. The resulting PLE extracts were pre-concentrated by molecularly imprinted solid phase extraction (MISPE) cartridges followed of analysis by HPLC with fluorescence detection (λexc = 258, λem = 440 nm). The proposed method was applied to the analysis of AOH and AME in fortified tomato samples (20–72 µg· kg–1) with recoveries of 84–97% (RSD < 8%, n = 6) for AOH and 67–91% (RSD < 13%, n = 6) for AME. The detection limit for AOH and AME were 7 and 15 µg· kg–1, respectively. The ensuing PLE–MISPE–HPLC–FLD method was validated for the analysis of both mycotoxins in tomato samples in accordance with European Commission Decision 2002/657/EC.