In this paper, we describe the PERFORM system for the continuous remote monitoring and management of Parkinson’s disease (PD) patients. The PERFORM system is an intelligent closed-loop system that seamlessly integrates a wide range of wearable sensors constantly monitoring several motor signals of the PD patients. Data acquired are pre-processed by advanced knowledge processing methods, integrated by fusion algorithms to allow health professionals to remotely monitor the overall status of the patients, adjust medication schedules and personalize treatment. The information collected by the sensors (accelerometers and gyroscopes) is processed by several classifiers. As a result, it is possible to evaluate and quantify the PD motor symptoms related to end of dose deterioration (tremor, bradykinesia, freezing of gait (FoG)) as well as those related to over-dose concentration (Levodopa-induced dyskinesia (LID)). Based on this information, together with information derived from tests performed with a virtual reality glove and information about the medication and food intake, a patient specific profile can be built. In addition, the patient specific profile with his evaluation during the last week and last month, is compared to understand whether his status is stable, improving or worsening. Based on that, the system analyses whether a medication change is needed—always under medical supervision—and in this case, information about the medication change proposal is sent to the patient. The performance of the system has been evaluated in real life conditions, the accuracy and acceptability of the system by the PD patients and healthcare professionals has been tested, and a comparison with the standard routine clinical evaluation done by the PD patients’ physician has been carried out. The PERFORM system is used by the PD patients and in a simple and safe non-invasive way for long-term record of their motor status, thus offering to the clinician a precise, long-term and objective view of patient’s motor status and drug/food intake. Thus, with the PERFORM system the clinician can remotely receive precise information for the PD patient’s status on previous days and define the optimal therapeutical treatment.
Wearable technologies for health monitoring have become a reality in the last few years. So far, most research studies have focused on assessments of the technical performance of these systems, as well as the validation of the clinical outcomes. Nevertheless, the success in the acceptance of these solutions depends not only on the technical and clinical effectiveness, but on the final user acceptance. In this work the compliance of a telehealth system for the remote monitoring of Parkinson’s disease (PD) patients is presented with testing in 32 PD patients. This system, called PERFORM, is based on a Body Area Network (BAN) of sensors which has already been validated both from the technical and clinical point for view. Diverse methodologies (REBA, Borg and CRS scales in combination with a body map) are employed to study the comfort, biomechanical and physiological effects of the system. The test results allow us to conclude that the acceptance of this system is satisfactory with all the levels of effect on each component scoring in the lowest ranges. This study also provided useful insights and guidelines to lead to redesign of the system to improve patient compliance.
Parkinson’s disease (PD) alters the motor performance of affected individuals. The dopaminergic denervation of the striatum, due to substantia nigra neuronal loss, compromises the speed, the automatism and smoothness of movements of PD patients. The development of a reliable tool for long-term monitoring of PD symptoms would allow the accurate assessment of the clinical status during the different PD stages and the evaluation of motor complications. Furthermore, it would be very useful both for routine clinical care as well as for testing novel therapies. Within this context we have validated the feasibility of using a Body Network Area (BAN) of wireless accelerometers to perform continuous at home gait monitoring of PD patients. The analysis addresses the assessment of the system performance working in real environments.
Parkinson's disease (PD) predominantly alters the motor performance of the affected individuals. In particular, the loss of dopaminergic neurons compromises the speed, the automaticity and fluidity of movements. As the disease evolves, PD patient's motion becomes slower and tremoric and the response to medication fluctuates along the day. In addition, the presence of involuntary movements deteriorates voluntary movement in advanced state of the disease. These changes in the motion can be detected by studying the variation of the signals recorded by accelerometers attached in the limbs and belt of the patients. The analysis of the most significant changes in these signals make possible to build an individualized motor profile of the disease, allowing doctors to personalize the medication intakes and consequently improving the response of the patient to the treatment. Several works have been done in a laboratory and supervised environments providing solid results; this work focused on the design of unsupervised method for the assessment of gait in PD patients. The development of a reliable quantitative tool for long-term monitoring of PD symptoms would allow the accurate detection of the clinical status during the different PD stages and the evaluation of motor complications. Besides, it would be very useful both for routine clinical care as well as for novel therapies testing.
11 September 2015 in BMC Medical Informatics and Decision Making
The assessment of a new health technology is a multidisciplinary and multidimensional process, which requires a complex analysis and the convergence of different stakeholders into a common decision. This task is even more delicate when the assessment is carried out in early stage of development processes, when the maturity of the technology prevents conducting a large scale trials to evaluate the cost effectiveness through classic health economics methods. This lack of information may limit the future development and deployment in the clinical practice. This work aims to 1) identify the most relevant user needs of a new medical technology for managing and monitoring Parkinson's Disease (PD) patients and to 2) use these user needs for a preliminary assessment of a specific system called PERFORM, as a case study.
The current work describes a methodology to automatically detect the severity of bradykinesia in motor disease patients using wireless, wearable accelerometers. This methodology was tested with cross validation through a sample of 20 Parkinson's disease patients. The assessment of methodology was carried out through some daily living activities which were detected using an activity recognition algorithm. The Unified Parkinson's Disease Rating Scale (UPDRS) severity classification of the algorithm coincides between 70 and 86% from that of a trained neurologist depending on the classifier used. These severities were calculated for 5 second segments of the signal with 50% of overlap. A bradykinesia profiler is also presented in this work. This profiler removes the overlap of the segments and calculates the confidence of the resulting events. It also calculates average severity, duration and symmetry values for those events. The profiler has been tested with a bogus dataset. Future work includes better training for the severity classifier with a larger sample and testing the profiler with real, longterm patient data in a projected pilot phase in three European hospitals.