David Morales-Alamo

Dr. David Morales-Alamo

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2016 in Scandinavian Journal of Medicine & Science in Sports
Verified
Journal Article
Open access
PDF file
FPFernando Pareja-Blanco
Fernando Pareja-Blanco
DRD. Rodríguez‐Rosell
D. Rodríguez‐Rosell
LSL. Sánchez‐Medina
L. Sánchez‐Medina
JSJ. Sanchis‐Moysi
J. Sanchis‐Moysi
CDC. Dorado
C. Dorado
JGJ. J. González‐Badillo
J. J. González‐Badillo
We compared the effects of two resistance training (RT) programs only differing in the repetition velocity loss allowed in each set: 20% (VL20) vs 40% (VL40) on muscle structural and functional adaptations. Twenty‐two young males were randomly assigned to a VL20 (n = 12) or VL40 (n = 10) group. Subjects followed an 8‐week velocity‐based RT program using the squat exercise while monitoring repetition velocity. Pre‐ and post‐training assessments included: magnetic resonance imaging, vastus lateralis biopsies for muscle cross‐sectional area (CSA) and fiber type analyses, one‐repetition maximum strength and full load‐velocity squat profile, countermovement jump (CMJ), and 20‐m sprint running. VL20 resulted in similar squat strength gains than VL40 and greater improvements in CMJ (9.5% vs 3.5%, P < 0.05), despite VL20 performing 40% fewer repetitions. Although both groups increased mean fiber CSA and whole quadriceps muscle volume, VL40 training elicited a greater hypertrophy of vastus lateralis and intermedius than VL20. Training resulted in a reduction of myosin heavy chain IIX percentage in VL40, whereas it was preserved in VL20. In conclusion, the progressive accumulation of muscle fatigue as indicated by a more pronounced repetition velocity loss appears as an important variable in the configuration of the resistance exercise stimulus as it influences functional and structural neuromuscular adaptations.

21 December 2018 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
Ismael Perez-SuarezIsmael Perez-Suarez
Ismael Perez-Suarez
MMMarcos Martin-Rincon
Marcos Martin-Rincon
JHJuan José González Henríquez
Juan José González Henríquez
CFChiara Fezzardi
Chiara Fezzardi
SPSergio Perez-Regalado
Sergio Perez-Regalado
Jose A Lopez CalbetJose A Lopez Calbet
Jose A Lopez Calbet
The main aims of this study were to determine the accuracy of the portable metabolic cart K5 by comparison with a stationary metabolic cart (Vyntus CPX), to check on the validity of Vyntus CPX using a butane combustion test, and to assess the reliability of K5 during prolonged walks in the field. For validation, measurements were consecutively performed tests with both devices at rest and during submaximal exercise (bicycling) at low (60 W) and moderate intensities (130–160 W) in 16 volunteers. For the reliability study, 14 subjects were measured two times during prolonged walks (13 km, at 5 km/h), with the K5 set in mixing chamber (Mix) mode. Vyntus measured the stoichiometric RQ of butane combustion with high accuracy (error <1.6%) and precision (CV <0.5%), at VO2 values between 0.788 and 6.395 L/min. At rest and 60 W, there was good agreement between Vyntus and K5 (breath-by-breath, B×B) in VO2, VCO2, RER, and energy expenditure, while in Mix mode the K5 overestimated VO2 by 13.4 and 5.8%, respectively. Compared to Vyntus, at moderate intensity the K5 in B×B mode underestimated VO2, VCO2, and energy expenditure by 6.6, 6.9, and 6.6%, respectively. However, at this intensity there was an excellent agreement between methods in RER and fat oxidation. In Mix mode, K5 overestimated VO2 by 5.8 and 4.8%, at 60 W and the higher intensity, respectively. The K5 had excellent reliability during the field tests. Total energy expenditure per Km was determined with a CV for repeated measurements of 4.5% (CI: 3.2–6.9%) and a concordance correlation coefficient of 0.91, similar to the variability in VO2. This high reproducibility was explained by the low variation of FEO2 measurements, which had a CV of 0.9% (CI: 0.7–1.5%) combined with a slightly greater variability of FECO2, VE, VCO2, and RER. In conclusion, the K5 is an excellent portable metabolic cart which is almost as accurate as a state-of-art stationary metabolic cart, capable of measuring precisely energy expenditure in the field, showing a reliable performance during more than 2 h of continuous work. At high intensities, the mixing-chamber mode is more accurate than the B×B mode.

17 August 2018 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
Daniele A. CardinaleDaniele A. Cardinale
Daniele A. Cardinale
FLFilip J. Larsen
Filip J. Larsen
TSTomas A. Schiffer
Tomas A. Schiffer
DMDavid Morales-Alamo
David Morales-Alamo
BEBjörn Ekblom
Björn Ekblom
RBRobert Boushel
Robert Boushel
Sexual dimorphism is apparent in humans, however, to date no studies have investigated mitochondrial function focusing on intrinsic mitochondrial respiration (i.e., mitochondrial respiration for a given amount of mitochondrial protein) and mitochondrial oxygen affinity (p50mito) in relation to biological sex in human. A skeletal muscle biopsy was donated by nine active women, and ten men matched for maximal oxygen consumption (VO2max) and by nine endurance trained men. Intrinsic mitochondrial respiration, assessed in isolated mitochondria, was higher in women compared to men when activating complex I (CIP) and complex I+II (CI+IIP) (p < 0.05), and was similar to trained men (CIP, p = 0.053; CI+IIP, p = 0.066). Proton leak and p50mito were higher in women compared to men independent of VO2max. In conclusion, significant novel differences in mitochondrial oxidative function, intrinsic mitochondrial respiration and p50mito exist between women and men. These findings may represent an adaptation in the oxygen cascade in women to optimize muscle oxygen uptake to compensate for a lower oxygen delivery during exercise.

10 September 2015 in The Journal of Physiology
Verified
Journal Article
Closed access
PDF file
Jose A Lopez CalbetJose A Lopez Calbet
Jose A Lopez Calbet
JLJose Losa-Reyna
Jose Losa-Reyna
RTRafael Sánchez de Torres-Peralta
Rafael Sánchez de Torres-Peralta
PRPeter Rasmussen
Peter Rasmussen
Jesús Ponce GonzálezJesús Ponce González
Jesús Ponce González
CLCarsten Lundby
Carsten Lundby

14 September 2015 in The Journal of Physiology
Verified
Journal Article
Closed access
PDF file
DMDavid Morales-Alamo
David Morales-Alamo
JLJose Losa-Reyna
Jose Losa-Reyna
RTRafael Sánchez de Torres-Peralta
Rafael Sánchez de Torres-Peralta
MMMarcos Martin-Rincon
Marcos Martin-Rincon
MPMario Perez‐Valera
Mario Perez‐Valera
Jose A Lopez CalbetJose A Lopez Calbet
Jose A Lopez Calbet

30 September 2016 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
CZChristoph Zinner
Christoph Zinner
DMDavid Morales-Alamo
David Morales-Alamo
NØNiels Ørtenblad
Niels Ørtenblad
FLFilip J. Larsen
Filip J. Larsen
TSTomas A. Schiffer
Tomas A. Schiffer
HHHans-Christer Holmberg
Hans-Christer Holmberg
To elucidate the mechanisms underlying the differences in adaptation of arm and leg muscles to sprint training, over a period of 11 days 16 untrained men performed six sessions of 4-6x30-sec all-out sprints (SIT) with the legs and arms, separately, with a 1-h interval of recovery. Limb-specific VO2peak, sprint performance (two 30-sec Wingate tests with 4-min recovery), muscle efficiency and time-trial performance (TT, 5-min all-out) were assessed and biopsies from the m. vastus lateralis and m. triceps brachii taken before and after training. VO2peak and Wmax increased 3-11% after training, with a more pronounced change in the arms (P < 0.05). Gross efficiency improved for the arms (+8.8%, P < 0.05), but not the legs (-0.6%). Wingate peak and mean power outputs improved similarly for the arms and legs, as did TT performance. After training, VO2 during the two Wingate tests was increased by 52% and 6% for the arms and legs, respectively (P < 0.001). In the case of the arms, VO2 was higher during the first than second Wingate test (64% vs. 44%, P < 0.05). During the TT, relative exercise intensity, HR, VO2, VCO2, VE, and Vt were all lower during arm-cranking than leg-pedaling, and oxidation of fat was minimal, remaining so after training. Despite the higher relative intensity, fat oxidation was 70% greater during leg-pedaling (P = 0.017). The aerobic energy contribution in the legs was larger than for the arms during the Wingate tests, although VO2 for the arms was enhanced more by training, reducing the O2 deficit after SIT. The levels of muscle glycogen, as well as the myosin heavy chain composition were unchanged in both cases, while the activities of 3-hydroxyacyl-CoA-dehydrogenase and citrate synthase were elevated only in the legs and capillarization enhanced in both limbs. Multiple regression analysis demonstrated that the variables that predict TT performance differ for the arms and legs. The primary mechanism of adaptation to SIT by both the arms and legs is enhancement of aerobic energy production. However, with their higher proportion of fast muscle fibers, the arms exhibit greater plasticity.