David Morales-Alamo

Dr. David Morales-Alamo

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2016 in Scandinavian Journal of Medicine & Science in Sports
Verified
Journal Article
Open access
PDF file
FPFernando Pareja-Blanco
Fernando Pareja-Blanco
DRD. Rodríguez‐Rosell
D. Rodríguez‐Rosell
LSL. Sánchez‐Medina
L. Sánchez‐Medina
JSJ. Sanchis‐Moysi
J. Sanchis‐Moysi
CDC. Dorado
C. Dorado
JGJ. J. González‐Badillo
J. J. González‐Badillo
We compared the effects of two resistance training (RT) programs only differing in the repetition velocity loss allowed in each set: 20% (VL20) vs 40% (VL40) on muscle structural and functional adaptations. Twenty‐two young males were randomly assigned to a VL20 (n = 12) or VL40 (n = 10) group. Subjects followed an 8‐week velocity‐based RT program using the squat exercise while monitoring repetition velocity. Pre‐ and post‐training assessments included: magnetic resonance imaging, vastus lateralis biopsies for muscle cross‐sectional area (CSA) and fiber type analyses, one‐repetition maximum strength and full load‐velocity squat profile, countermovement jump (CMJ), and 20‐m sprint running. VL20 resulted in similar squat strength gains than VL40 and greater improvements in CMJ (9.5% vs 3.5%, P < 0.05), despite VL20 performing 40% fewer repetitions. Although both groups increased mean fiber CSA and whole quadriceps muscle volume, VL40 training elicited a greater hypertrophy of vastus lateralis and intermedius than VL20. Training resulted in a reduction of myosin heavy chain IIX percentage in VL40, whereas it was preserved in VL20. In conclusion, the progressive accumulation of muscle fatigue as indicated by a more pronounced repetition velocity loss appears as an important variable in the configuration of the resistance exercise stimulus as it influences functional and structural neuromuscular adaptations.

21 December 2018 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
Ismael Perez-SuarezIsmael Perez-Suarez
Ismael Perez-Suarez
MMMarcos Martin-Rincon
Marcos Martin-Rincon
JHJuan José González Henríquez
Juan José González Henríquez
CFChiara Fezzardi
Chiara Fezzardi
SPSergio Perez-Regalado
Sergio Perez-Regalado
Jose A Lopez CalbetJose A Lopez Calbet
Jose A Lopez Calbet
The main aims of this study were to determine the accuracy of the portable metabolic cart K5 by comparison with a stationary metabolic cart (Vyntus CPX), to check on the validity of Vyntus CPX using a butane combustion test, and to assess the reliability of K5 during prolonged walks in the field. For validation, measurements were consecutively performed tests with both devices at rest and during submaximal exercise (bicycling) at low (60 W) and moderate intensities (130–160 W) in 16 volunteers. For the reliability study, 14 subjects were measured two times during prolonged walks (13 km, at 5 km/h), with the K5 set in mixing chamber (Mix) mode. Vyntus measured the stoichiometric RQ of butane combustion with high accuracy (error <1.6%) and precision (CV <0.5%), at VO2 values between 0.788 and 6.395 L/min. At rest and 60 W, there was good agreement between Vyntus and K5 (breath-by-breath, B×B) in VO2, VCO2, RER, and energy expenditure, while in Mix mode the K5 overestimated VO2 by 13.4 and 5.8%, respectively. Compared to Vyntus, at moderate intensity the K5 in B×B mode underestimated VO2, VCO2, and energy expenditure by 6.6, 6.9, and 6.6%, respectively. However, at this intensity there was an excellent agreement between methods in RER and fat oxidation. In Mix mode, K5 overestimated VO2 by 5.8 and 4.8%, at 60 W and the higher intensity, respectively. The K5 had excellent reliability during the field tests. Total energy expenditure per Km was determined with a CV for repeated measurements of 4.5% (CI: 3.2–6.9%) and a concordance correlation coefficient of 0.91, similar to the variability in VO2. This high reproducibility was explained by the low variation of FEO2 measurements, which had a CV of 0.9% (CI: 0.7–1.5%) combined with a slightly greater variability of FECO2, VE, VCO2, and RER. In conclusion, the K5 is an excellent portable metabolic cart which is almost as accurate as a state-of-art stationary metabolic cart, capable of measuring precisely energy expenditure in the field, showing a reliable performance during more than 2 h of continuous work. At high intensities, the mixing-chamber mode is more accurate than the B×B mode.

17 August 2018 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
Daniele A. CardinaleDaniele A. Cardinale
Daniele A. Cardinale
FLFilip J. Larsen
Filip J. Larsen
TSTomas A. Schiffer
Tomas A. Schiffer
DMDavid Morales-Alamo
David Morales-Alamo
BEBjörn Ekblom
Björn Ekblom
RBRobert Boushel
Robert Boushel
Sexual dimorphism is apparent in humans, however, to date no studies have investigated mitochondrial function focusing on intrinsic mitochondrial respiration (i.e., mitochondrial respiration for a given amount of mitochondrial protein) and mitochondrial oxygen affinity (p50mito) in relation to biological sex in human. A skeletal muscle biopsy was donated by nine active women, and ten men matched for maximal oxygen consumption (VO2max) and by nine endurance trained men. Intrinsic mitochondrial respiration, assessed in isolated mitochondria, was higher in women compared to men when activating complex I (CIP) and complex I+II (CI+IIP) (p < 0.05), and was similar to trained men (CIP, p = 0.053; CI+IIP, p = 0.066). Proton leak and p50mito were higher in women compared to men independent of VO2max. In conclusion, significant novel differences in mitochondrial oxidative function, intrinsic mitochondrial respiration and p50mito exist between women and men. These findings may represent an adaptation in the oxygen cascade in women to optimize muscle oxygen uptake to compensate for a lower oxygen delivery during exercise.

10 September 2015 in The Journal of Physiology
Verified
Journal Article
Closed access
PDF file
Jose A Lopez CalbetJose A Lopez Calbet
Jose A Lopez Calbet
JLJose Losa-Reyna
Jose Losa-Reyna
RTRafael Sánchez de Torres-Peralta
Rafael Sánchez de Torres-Peralta
PRPeter Rasmussen
Peter Rasmussen
Jesús Ponce GonzálezJesús Ponce González
Jesús Ponce González
CLCarsten Lundby
Carsten Lundby

14 September 2015 in The Journal of Physiology
Verified
Journal Article
Closed access
PDF file
DMDavid Morales-Alamo
David Morales-Alamo
JLJose Losa-Reyna
Jose Losa-Reyna
RTRafael Sánchez de Torres-Peralta
Rafael Sánchez de Torres-Peralta
MMMarcos Martin-Rincon
Marcos Martin-Rincon
MPMario Perez‐Valera
Mario Perez‐Valera
Jose A Lopez CalbetJose A Lopez Calbet
Jose A Lopez Calbet

15 September 2012 in Journal of Applied Physiology
Verified
Journal Article
Open access
PDF file
DMDavid Morales-Alamo
David Morales-Alamo
Jesús Ponce GonzálezJesús Ponce González
Jesús Ponce González
Amelia Guadalupe‐GrauAmelia Guadalupe‐Grau
Amelia Guadalupe‐Grau
LRLorena Rodríguez-García
Lorena Rodríguez-García
ASAlfredo Santana
Alfredo Santana
Jose A Lopez CalbetJose A Lopez Calbet
Jose A Lopez Calbet
AMP-activated protein kinase (AMPK) is a major mediator of the exercise response and a molecular target to improve insulin sensitivity. To determine if the anaerobic component of the exercise response, which is exaggerated when sprint is performed in severe acute hypoxia, influences sprint exercise-elicited Thr172-AMPKα phosphorylation, 10 volunteers performed a single 30-s sprint (Wingate test) in normoxia and in severe acute hypoxia (inspired Po2: 75 mmHg). Vastus lateralis muscle biopsies were obtained before and immediately after 30 and 120 min postsprint. Mean power output and O2 consumption were 6% and 37%, respectively, lower in hypoxia than in normoxia. O2 deficit and muscle lactate accumulation were greater in hypoxia than in normoxia. Carbonylated skeletal muscle and plasma proteins were increased after the sprint in hypoxia. Thr172-AMPKα phosphorylation was increased by 3.1-fold 30 min after the sprint in normoxia. This effect was prevented by hypoxia. The NAD+-to-NADH.H+ ratio was reduced (by 24-fold) after the sprints, with a greater reduction in hypoxia than in normoxia ( P < 0.05), concomitant with 53% lower sirtuin 1 (SIRT1) protein levels after the sprint in hypoxia ( P < 0.05). This could have led to lower liver kinase B1 (LKB1) activation by SIRT1 and, hence, blunted Thr172-AMPKα phosphorylation. Ser485-AMPKα1/Ser491-AMPKα2 phosphorylation, a known negative regulating mechanism of Thr172-AMPKα phosphorylation, was increased by 60% immediately after the sprint in hypoxia, coincident with increased Thr308-Akt phosphorylation. Collectively, our results indicate that the signaling response to sprint exercise in human skeletal muscle is altered in severe acute hypoxia, which abrogated Thr172-AMPKα phosphorylation, likely due to lower LKB1 activation by SIRT1.