Two schemes are mainly used for coding sounds in cochlear implants: Fixed-Channel and Channel-Picking. This study aims to determine the speech audiometry scores in noise of people using either type of sound coding scheme. Twenty normal-hearing and 45 cochlear implant subjects participated in this experiment. Both populations were tested by using dissyllabic words mixed with cocktail-party noise. A cochlear implant simulator was used to test the normal-hearing subjects. This simulator separated the sound into 20 spectral channels and the eight most energetic were selected to simulate the Channel-Picking strategy. For normal-hearing subjects, we noticed higher scores with the Fixed-Channel strategy than with the Channel-Picking strategy in the mid-range signal-to-noise ratios (0 to +6 dB). For cochlear implant users, no differences were found between the two coding schemes but we could see a slight advantage for the Fixed-Channel strategies over the Channel-Picking strategies. For both populations, a difference was observed for the signal-to-noise ratios at 50% of the maximum recognition plateau in favour of the Fixed-Channel strategy. To conclude, in the most common signal-to-noise ratio conditions, a Fixed-Channel coding strategy may lead to better recognition percentages than a Channel-Picking strategy. Further studies are indicated to confirm this.
25 February 2011 in Journal of the Association for Research in Otolaryngology
Broader intra-cochlear current spread (ICCS) implies higher cochlear implant (CI) channel interactions. This study aimed to investigate the relationship between ICCS and speech intelligibility in experienced CI users. Using voltage matrices collected for impedance measurements, an individual exponential spread coefficient (ESC) was computed. Speech audiometry was performed to determine the intelligibility at 40 dB Sound Pressure Level (SPL) and the 50% speech reception threshold: I40 and SRT50 respectively. Correlations between ESC and either I40 or SRT50 were assessed. A total of 36 adults (mean age: 50 years) with more than 11 months (mean: 34 months) of CI experience were included. In the 21 subjects for whom all electrodes were active, ESC was moderately correlated with both I40 (r = −0.557, p = 0.009) and SRT50 (r = 0.569, p = 0.007). The results indicate that speech perception performance is negatively affected by the ICCS. Estimates of current spread at the closest vicinity of CI electrodes and prior to any activation of auditory neurons are indispensable to better characterize the relationship between CI stimulation and auditory perception in cochlear implantees.
Conclusion: The Harmony processor was found to be reliable, comfortable and offered a substantially increased battery life compared with the previous generation processor. No significant improvement in speech understanding with HiRes was demonstrated from objective measures, but the majority of subjects showed a clear subjective preference for the combination HiRes 120/Harmony processor. Objectives: To evaluate experience with the Harmony™ sound processor, together with the HiRes 120 strategy. Methods: Postlingually deafened adults implanted with a CII or HiRes 90K were included and divided into three groups: (1) experienced users using the Platinum body-worn processor; (2) experienced users who had been using other processors; (3) new users with the Harmony processor from first fitting. The latter group entered a randomized crossover protocol where half were initially fitted with HiRes and half with HiRes 120. The initial strategy was used for 3 months and the alternative for a further 3 months. Speech perception tests and questionnaires were performed. Results: The study included 65 subjects. Implementing HiRes 120 was straightforward. The speech test group results did not show significant differences between HiRes and HiRes 120. However, the questionnaires showed significantly higher ratings for HiRes 120 in some instances. Subjects were highly satisfied with the Harmony processor.