High-frequency current transformers are popular noninvasive inductive wideband sensors. Despite the simplicity in design and operational principle, implementation of such sensors for partial discharge (PD) applications requires careful consideration, particularly in the higher frequency range where traveling wave attenuation and distortion are relevant. First, the role of design variables, including core materials, winding design, and shielding practices on sensor sensitivity and frequency characteristics (transfer impedance), is presented. Next, the suitability of the constructed sensors for PD applications is assessed. The designed wideband sensors are suitable for laboratory applications with standard measurement circuits and controlled conditions. The low-level magnitude and frequency spectrum of the discharge pulses hinders signal integrity in relation to the placement of the sensors within the measurement circuit, signal amplification, and pulse repetition rate (pulse resolution). To enable the most stringent detection levels under 1 pC, efforts are needed in distortionless amplifier design and interference mitigation.

22 May 2019 in High Voltage
Verified
Journal Article
Open access
PDF file
JKJoni Kluss
Joni Kluss
MCMojtaba Rostaghi Chalaki
Mojtaba Rostaghi Chalaki
WWWilburn Whittington
Wilburn Whittington
HRHongjoo Rhee
Hongjoo Rhee
SWSamuel Whittington
Samuel Whittington
AYAref Yadollahi
Aref Yadollahi
Porcelain insulators have a long history and wide application range in power systems, but just like any other insulator, they can fail. A number of pole fires occurred on lines utilising porcelain suspension insulators. In some cases, the insulators appeared to be visually intact with no external signs of degradation or abnormal stress. This prompted a comprehensive assessment to identify the mechanism that leads to the permanent loss of insulating properties while retaining external physical characteristics. A single test is not sufficient to determine the underlying cause of conduction as results may produce contradictory conclusions. Electrical tests were able to identify samples with poor dielectric strength. Nevertheless, these same samples exhibited excellent mechanical properties. Despite successfully passing numerous porosity tests, scanning electron microscopic analysis revealed porosity and multiple microscopic punctures in the porcelain dielectric. Only upon complete dissection of samples, the conduction mechanism was revealed. This article discusses the challenges associated with establishing the root failure mechanism for the investigated porcelain insulators that allows visually sound samples to lose their insulating properties without experiencing catastrophic failure.

14 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Carlos Vera RomeroCarlos Vera Romero
Carlos Vera Romero
FGFernando Garnacho
Fernando Garnacho
JKJoni Kluss
Joni Kluss
CMChristian Mier
Christian Mier
FÁFernando Álvarez
Fernando Álvarez
ASAntonio Squicciarini
Antonio Squicciarini
The insulation condition of HVDC grids consisting of cable systems, GIS, and converters should be monitored by partial discharge (PD) analysers using artificial intelligence (AI) tools for efficient insulation diagnosis. Although there are many experiences of PD monitoring solutions developed for the supervision of the insulation condition of HVAC grids using PD analysers, there are no standardised requirements for their qualification available yet. The international technical specification TS IEC 62478 provides general rules for PD measurements using electromagnetic methods but does not define performance requirements for qualification tests. HVDC and HVAC PD analysers must be tested by unambiguous test procedures. This paper compiles experiences of using PD analysers with HFCT sensors in HVAC grids (cable systems, GIS, and AIS) to define a qualification procedure for HVAC systems. This procedure is applicable to HVDC grids (cable systems, GIS, AIS, and converters) because the particularities related to the insulation behaviour under HVDC voltage are also considered. Representative PD sources are discussed in HVAC and HVDC positive and negative polarity. The PD pulse trend of representative insulation defects in HVDC cable systems is quite different from that of HVAC grids. Special attention should be paid to the acquisition of PD signals in HVDC grids since few pulses appear in solid insulations, mainly during voltage changes (polarity reversals or surges), but rarely in continuous operation with constant direct voltage. A synthetic PD simulator has been developed to reproduce trains of PD pulses or noise signals, similar to those that can appear in the power network. A set of three functionality tests has been developed for qualification of the diagnostic capabilities of PD analysers working up to 30 MHz addressed to HVDC or HVAC grids: (1) PD recognition test, (2) PD clustering test, and (3) PD location test. This qualification procedure has been validated by means of a round-robin test performed by five research institutes (RISE, FFII, TUDelft, TAU, and UPM) using commercial and in-development AI PD recognition and clustering tools to demonstrate its robustness and applicability. Applying this qualification procedure, two PD methods for electrical detection and prevention of insulation defects have been approved, one for HVAC and the other for HVDC grids.

11 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
FGFernando Garnacho
Fernando Garnacho
FÁFernando Álvarez
Fernando Álvarez
AEAlf-Peter Elg
Alf-Peter Elg
CMChristian Mier
Christian Mier
KLKari Lahti
Kari Lahti
MHMiran Haider
Miran Haider
On-site partial discharge (PD) measurements have turned out to be a very efficient technique for determining the insulation condition in high-voltage electrical grids (AIS, cable systems, GIS, HVDC converters, etc.); however, there is not any standardised procedure for determining the performances of PD measuring systems. In on-line and on-site PD measurements, high-frequency current transformers (HFCTs) are commonly used as sensors as they allow for monitoring over long distances in high-voltage installations. To ensure the required performances, a metrological qualification of the PD analysers by applying an evaluation procedure is necessary. A novel evaluation procedure was established to specify the quantities to be measured (electrical charge and PD repetition rate) and to describe the evaluation tests considering the measured influence parameters: noise, charge amplitude, pulse width and time interval between consecutive pulses. This procedure was applied to different types of PD analysers used for off-line measurements, sporadic on-line measurements and continuous PD monitoring. The procedure was validated in a round-robin test involving two metrological institutes (RISE from Sweden and FFII from Spain) and three universities (TUDelft from the Netherlands, TAU from Finland and UPM from Spain). With this round-robin test, the effectiveness of the proposed qualification procedure for discriminating between efficient and inappropriate PD analysers was demonstrated. Furthermore, it was shown that the PD charge quantity can be properly determined for on-line measurements and continuous monitoring by integrating the pulse signals acquired with HFCT sensors. In this case, these sensors must have a flat frequency spectrum in the range between several tens of kHz and at least two tens of MHz, where the frequency pulse content is more significant. The proposed qualification procedure can be useful for improving the future versions of the technical specification TS IEC 62478 and the standard IEC 60270.


1 February 2019
Verified
Conference Paper
Closed access
MMMohammed Ahmed Mousa
Mohammed Ahmed Mousa
Sherif AbdelwahedSherif Abdelwahed
Sherif Abdelwahed
JKJoni Kluss
Joni Kluss
The following topics are dealt with: power grids; distributed power generation; photovoltaic power systems; optimisation; power generation control; smart power grids; power generation economics; power engineering computing; load flow; power electronics.